22
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal ID
Hard Pipe or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Fig. 4
Icemaker
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Two-inch
(5 cm) air gap
Floor Drain
Icemaker
Drain Outlet
3/4" FPT
Ice
Storage
Bin
Model Shown:
F-801MAH
Vent Tube
Minimum 3/4" Nominal ID
Hard Pipe or Equivalent
Air-Cooled and Remote Models
Drain Valve
Shut-Off Valve
Separate piping to
approved drain. Leave a
two-inch (5 cm) vertical air
gap between the end of
each pipe and the drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Minimum 1/4" Nominal ID Copper
Water Tubing or Equivalent