C. Settings and Adjustments
1. Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
DCM-271BAH(-OS) OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
Bin Control Shutdown Delay (infrared sensor)
(not used on this model)
Continuous Dispensing Timer
(Do not adjust on DCM-271BAH-OS)
Drain Frequency Control
Bin Control Selector
Bin Control Shutdown Delay (mechanical) and Periodic Agitation
of Storage Bin
Normally off (factory use)
2. Bin Control Shutdown Delay (Infrared Sensor) (S1 dip switch 1, 2, 3)
NOTICE
Do not adjust. Setting not used on this model. When dip switch 7 is off, dip switch
1, 2, and 3 are ignored.
Factory set. DCM-271BAH(-OS) does not use a bin control with an infrared sensor.
The appliance uses a bin control with a mechanical micro-switch for ice level control.
3. Drain Frequency Control (S1 dip switch 4)
The appliance is factory set for optimum performance with the 1-in-1 drain cycle (S1 dip
switch 4 in the "OFF" position). This setting allows for removal of sediment from the
evaporator without interrupting the icemaking process.
NOTICE!
Do not adjust S1 dip
switch 4 out of the factory default position. This dip switch must be left in the
factory default position or the appliance will not operate correctly.
S1 Dip Switch Setting
Drain Timer Interval Drain Valve Open
No. 4
OFF (1-in-1)
1 Hour
2 Seconds
ON (1-in-12)
11 Hours 45 Minutes
10 Minutes