18
CO2 cylinder
(9) Cylinder runs out of gas easily
Reference: Approx. 900L of beer is available with a 22lb (10kg) CO2 at 43PSIG (0.3MPa).
Possible Cause
Remedy
1. CO2 gas leak.
1-1 Gasket out of position and tightening
nut loosened at pressure reducing
valve and cylinder connection.
1-2 Loose or incorrect hose bands on both
ends of gas hose.
1-3 Defective gasket in keg coupler
1-4 Loose gas hose joint.
1-1 If gasket is damaged, replace. Securely tighten
tightening nut using spanner and apply soapy water to
check for CO2 gas leak.
1-2 Check correct hose band type and insert gas hose deep
into quick gas hose joint.
1-3 Replace gasket.
1-4 Securely tighten gas hose joint.
Leak
(10) Cooling water mixed with beer comes out of overflow pipe on unit front
Possible Cause
Remedy
1. Beer leaking from joint nut on beer coil
connected to tap mounting shaft inside
cooling water tank.
1. Check for damaged O-ring at joint nut. If there is no
damage, reassemble. If damaged, replace.
(11) Beer tap joint leaks beer
Possible Cause
Remedy
1. Beer leaking from union nut of beer tap.
1. Remove beer tap and check for damaged O-ring.
If there is no damage, reassemble. If damaged, replace.
(12) Unit leaks water
Possible Cause
Remedy
1. Cooling water overflowing drain pan.
1. Instruct user to empty drain pan everyday.
2. Condensate leaking from unit.
2. Instruct user to maintain ambient humidity at 84% or less.
Tightly wrap refrigeration circuit with insulation pipe.