Horstmann 425 range Скачать руководство пользователя страница 2

Once the backplate has been removed from the 
packaging please ensure the programmer is re-sealed  
to prevent damage from dust, debris etc.

The backplate should be fitted with the wiring terminals 
located at the top and in a position which allows the 
relevant clearances around the programmer  
(see diagram)

DIRECT WALL MOUNTING

Offer the plate to the wall in the position where the programmer is to be mounted, remembering 
that the backplate fits to the right hand end of the programmer.
Mark the fixing positions through the slots, (fixing centres 60.3mm), drill and plug the wall, then 
secure the plate in position. The slots in the backplate will compensate for any misalignment of the 
fixings.

WIRING BOX MOUNTING

The backplate may also be fitted directly on to a single gang steel flush wiring box complying 
withBS4662, using two M3.5 screws.
425 electro mechanical programmers are suitable for mounting on a flat surface only, they must not 
be positioned on a surface mounted wall box or on unearthed metal surfaces.

ELECTRICAL CONNECTIONS

All necessary electrical connections should now be made. Flush wiring can enter from the rear 
through the aperture in the backplate. Surface wiring can only enter from beneath the programmer 
and must be securely clamped.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring.
The recommended cable sizes are 1.0mm² or 1.5mm² for a Diadem/Tiara and 1.5mm² for a 
Coronet.
425 Electro-Mechanical Programmers are double insulated and do not require an earth connection 
but an earth terminal is provided on the backplate for terminating any cable earth conductors.
Earth continuity must be maintained and all bare earth conductors must be sleeved. Ensure that no 
conductors are left protruding outside the central space enclosed by the backplate.

Fitting the backplate:

 

END VIEW OF 425 ELECTRO-MECHANICAL PROGRAMMER

Содержание 425 range

Страница 1: ...th the twin circuit Diadem and Tiara also allowing independent control of both INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS WARNING ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION Horstmann 425 range Installation Instructions ...

Страница 2: ...425 electro mechanical programmers are suitable for mounting on a flat surface only they must not be positioned on a surface mounted wall box or on unearthed metal surfaces ELECTRICAL CONNECTIONS All necessary electrical connections should now be made Flush wiring can enter from the rear through the aperture in the backplate Surface wiring can only enter from beneath the programmer and must be sec...

Страница 3: ...g the interlock located at the top of the HW programme slide First select Twice on the HW selector slide then select the Off position on the CH selector slide this will reveal the screwdriver slot in the interlock Position the screwdriver in the slot and rotate anti clockwise until the slot is almost horizontal a stop will prevent the interlock from being turned too far Check for correct operation...

Страница 4: ...ILER PUMP E N L MAINS SUPPLY N L 1 2 3 4 5 6 ROOM STAT N C CALL SAT N N L L BOILER PUMP CYL STAT CALL SAT C E N L MAINS SUPPLY N L 1 2 3 4 5 6 ROOM STAT N C CALL SAT CYL STAT CALL SAT C N L PUMP BOILER ZONE VALVE ZONE VALVE E N L MAINS SUPPLY N L 1 2 3 4 5 6 N C CALL SAT BR BL W GR 0 CALL SAT C N N L L BOILER PUMP ROOM STAT CYL STAT ZONE VALVE E N L MAINS SUPPLY N L 1 2 3 4 5 6 N C CALL SAT CALL S...

Страница 5: ...al slots in the backplate Tighten the two captive retaining screws to fix the unit securely then switch on the mains supply The tappets can now be set to suit the user s requirements Please refer to the user s guide provided GENERAL INFORMATION Before handing over the installation to the user always ensure that the system responds correctly on all control programmes and that other electrically ope...

Страница 6: ... Thermoplastic flame retardant Dimensions 153mm x 112mm x 33mm Clock 24 hour Programme selection 24 Hours On all day Twice Off Operating periods per day Two Override Instant advance Backplate 9 Pin terminal connection Leaflet number P27673 Issue 17 6 Email sales horstmann co uk Website www horstmann co uk Horstmann Bristol BS4 1UP Tel 0117 978 8700 Fax 0117 978 8701 Horstmann is a trading name of ...