Manual Overrides

ADVANCE CONTROL

The advance control allows you to start an ON or OFF period early without altering the tappet, time 
or programme selection settings. Moving the advance control to the extreme right brings forward 
the operation of the next tappet. The switch state indicator then changes to the appropriate number. 
When the next tappet passes the time line, normal operation returns.
When the programme selector is in the All Day position, tappets 2 and 3 do not operate. If you 
require switching the system OFF for the day, after the morning switch ON, you will need to step 
forward with the advance switch until the number 4 is shown in the switch state indicator.

If you wish to switch ON and OFF by hand or vice versa, before the next automatic switching 
operation, the advance control must be operated until the switch state indicator is returned to the 
correct automatic sequence.

EXAMPLE: If you turn the system ON 
again after the preset night shut down 
time, when you turn it OFF before retiring 
make sure to operate the advance switch 
again until the number 4 is displayed in 
the switch state indicator so that the red 
tappet number 1 will switch the system 
ON in the morning.

DO NOT OPERATE THE ADVANCE 
SWITCH WHEN A TAPPET IS AGAINST  
THE TIME LINE.

SWITCH STATE INDICATOR

Located above the ADVANCE switch, the switch state indicator shows you the number of the tappet 
which operated last.
Eg. If the system was switched ON by tappet 1 at 7:00am and it is now 9:00am, providing that no 
further tappets operations have past, a number 1 should show in the aperture.
If the switch state indicator does not agree with the programme set on the dial, rotate the dial one 
whole turn and reset to the correct time of day. This will ensure that the switch state corresponds to 
the last tappet operation.