Blockage Mode
Sensitivity is used to set up blockage monitoring. The sensitivity
value (between 1 and 100) sets the minimum seeds per second that
seed must flow through the sensors before a blockage alarm occurs.
It is normal for seed flow rate to vary slightly during seeding. The
goal is to set the sensitivity value high enough to detect actual
blockages without causing nuisance alarms due to slight variations in
seed flow rate.
To set the sensitivity:
1. Check the condition of the air seeder and ensure that there
are no blockages.
2. Begin seeding.
3. On the Main screen, tap the sensitivity icon
.
4. Tap Wizard and the system will look at the seeds/second
counted by the sensors and select the optimum sensitivity
value for you.
You can also enter a value manually.
1. Instead of tapping Wizard enter in a value between 0 & 100.
2. Tap Update after a value has been manually entered.
3. When loop is operating normally in blockage mode, all of the
sensors should be
green
.
Tip:
A Blockage Sensitivity value of zero (0)
disables the power and alarms to the
Sensor loop.
You must be seeding in order to set
Sensitivity correctly.
Note:
Sensitivity relates to blockage
monitoring and detects whether the
number of seeds flowing through a
sensor over a period of time (e.g. 20
seeds per second) drops below the
minimum rate.
Note:
If the system is powered On and left to
sit unattended for an extended period of
time up to 30 minutes or more, the
LEGEND system on the blockage monitor
will reset any previously set sensitivity
level back to zero (0).
Figure 6-3
Figure 6-4
Product Setup
The Legend has the ability to save your calibrations for a specific
product, to recall at a later date.
To save a product:
1. Tap the Calibration Wizard.
A box opens and the on-screen keyboard appears.
2. Instead of entering a seed rate again, select the Product soft
key.
The Product Setup screen appears.
3. Select an unused slot.
A box opens and the on-screen keyboard appears.
4. Enter in the product name and select Save. To
recall a product:
1. Tap the Calibration Wizard.
A box opens and the on-screen keyboard appears.
2. Instead of entering a seed rate again, select the Product soft
key.
The Product Setup screen appears.
3. Select the product you wish to recall.
A box opens and the on-screen keyboard appears.
4. Select Recall.
The app will return to the main screen and the product name
should appear under the Seed Rate Wizard.
Figure 6-5
Figure 6-6
27
Содержание Avatar SD 40
Страница 1: ...1...
Страница 2: ......
Страница 12: ...Avatar SD40 Work screen 12...
Страница 13: ...Avatar SD40 Work screen 13...
Страница 14: ...Avatar SD40 Work screen 14...
Страница 16: ...Avatar SD40 Meter calibration 16...
Страница 20: ...20 Rotors Standard Crop...
Страница 21: ...21 Rotors Standard Crop continued...
Страница 22: ...22 Rotors Fertilizer...
Страница 23: ...23 Rotors Small Seed...
Страница 25: ...Blockage Monitoring System Advanced Air Drill Rate and Blockage System 25...
Страница 29: ...Notes...