Troubleshooting
Display / error
Meaning
Possible causes
Solution options
Bar graph
Coulter pressure always in the yellow range
Contact force of the depth guide wheels on the ground
too high.
Check the detail screen /
Machine data 3
screen
The target value is set too low.
Check nominal value setting.
The dead weight of the drill unit is too high (the hydraulic
coulter pressure display on the hopper shows 0 bar at
light soil conditions).
Sensor zero point shift / sensor is defective.
Recalibrate the sensor or replace the sensor if calibration
is not possible.
Bar graph
Coulter pressure always in the red range
The contact force of the depth guide wheels on the
ground is too high.
The drilling depth is not kept.
Check the detail screen /
Machine data 3
screen
The drilling speed is too high.
Reduce the drilling speed.
The hydraulic coulter pressure is too low.
Feed pressure fan = coulter pressure
¾
Check the pressure gauge on the fertiliser hopper.
Increase the speed of fertiliser and Seed On Demand
fan (pneumatic bypass, consultation with HORSCH
required).
Springs required for pretension of the drill units.
Working conditions too tough.
Tillage necessary
Ground contact lost
message
No adequate coulter pressure can be built up. The
resistance is too great.
The force measured is too low over a certain period.
There is no ground contact. Correct seed placement is
not ensured.
The target value is too low.
Increase the target value.
Working conditions too tough.
Tillage necessary.
Free movement of the parallelogram on the drill unit is
limited.
Check the parallelogram and restore free movement.
Plastic deformation
message
The sensor is no longer included in the calculation of the
values of the control.
The sensor was plastically deformed.
Check the sensor and replace it, if necessary.
Note the section
Sensor plastically deformed
(ErrorCode 128)
.
No coulter pressure in manual or automatic mode
Faulty configuration
Check the configuration settings:
Under
Coulter pressure adj.
Hyd auto
or
Bu auto
must be
selected.
Follow the
Configuration
section in this regard.
Coulter pressure valves defective
Check the selection of the coulter pressure valves in the
Diagnostics
menu.
Sensor calibration (Teach) not possible
The following prerequisites must be met to be able to
perform the calibration:
• No speed signal
• No working signal
• Machine unfolded
• Drill units do not touch the ground
• Value range (without load) in which the sensor can be
calibrated: 2.8 mA - 5.2 mA
One or more of these prerequisites are not met.
Wire break (ErrorCode 87)
The connection between job computer and sensor is
interrupted.
¾
Check all cables and plug-and-socket connections
between job computer and sensor.
¾
Replace defective components as required.
Short-circuit (ErrorCode 88)
There is a short-circuit between the sensor and the job
computer.
¾
Check all cables and plug-and-socket connections
between job computer and sensor.
¾
Replace defective components as required.
Sensor zero point shift
Open
Diagnostics
and check the sensor values.
Values without load: 3.8 - 4.5 mA
Values with excessive load: > 4.5 mA
Sensor can be calibrated if the value lies between
2.8 - 5.2 mA.
Sensor must be checked
Without load (drill unit raised, machine unfolded) the
value of the sensor is roughly 4 mA.
The value changes by lifting the corresponding depth
guide wheel.
Never place objects under the depth guide wheels and
lower the coulter bar on it. The entire machine weight
rests on the sensor. It is destroyed from overload.
20
21