2.  GETTING STARTED 

2.1  Unboxing 

Our packaging is designed to protect the luminaire during shipping.  Please inspect to confirm it was 
not damaged in during the process. 

2.2  Handling 

Once unpacked, the luminaire can become damaged if mishandled.  Do not stack luminaires after 
unpacking.  Protect the remote phosphor plate from scratching. 

2.3  Package Contents 

Light fixture 

– assembled 

Power Driver 

Installation Instructions 

3.  INSTALLATION 

3.1  Mounting Driver 

The A100A comes with the power supply mounted inside the fixture.  There is no need to move the driver 
or install a remote mounted driver 

3.2   Adjusting Mounting Angle 

The A-100A luminaire has an adjustable mounting elbow that can be mounted either horizontally or 
vertically with the light source facing down.  First, adjust elbow appropriately to application. The unit will 
originally be assembled for horizontal mount.  To change to vertical mount prior to installation: 

1)  Loosen two adjustment bolts on the mounting bracket 
2)  Rotate bracket 180° such that the mounting pole opening faces down. 
3)  Tighten adjustment bolts to 15 ft-lbs. 

3.3  Pole Mounting 
Warning: Make sure no power is going to the luminaire during installation procedure 

4)  Protect remote phosphor plate for installation. 
5)  Loosen the two mounting bolts such that the luminaire will slide over the pole. 
6)  Slip luminaire over pole with phosphor plate facing down and level to ground. 
7)  Tighten two mounting bolts to 15 ft-lbs.  
8)  Connect lead wire from LED Driver to power source. 

 

 

 

 

 

 

 

Figure 1 - A100A Mounting Orientation

 

Отзывы: