HORMIX BET 160 EST ELE 0.75 HP Скачать руководство пользователя страница 11

 

11 

 

1 - PRESENTATION: 

HORMIX

 concrete mixers have been conceived to fully execute the hardest jobs under the worst conditions. Its design has been studied and the 

materials that intervene in its manufacture chosen; in order to obtain a robust and swift set of modern conception. 

It’s perfectly balanced transmission and rotation mechanisms as well as the double effect mixers surpass conventional productivity. Our goal is 

to improve and make the work of the machines that we produce more efficient.   For this reason we reserve the right to vary its mechanisms, 
forms etc. HORMIX concrete mixers have the 

CE

 marking fulfilling the norms in force according to the 

CATIM

 report. 

 

2 — GENERAL SECURITY INSTRUCTIONS 

When using this equipment be sure to follow the regulations applied in order to reduce the risk

 

inherent to its usage.

 

-» Read this Instruction Manual intently.

 

-» Only use the machine according to the instructions in this manual  
-» The operator should be fully trained and qualified to operate this machine. 
-» The operator should wear close-fitting clothing; hair tied and should be familiar with the functioning of the machine. 
-» Always keep the work zone clean, free of objects and with the necessary illumination. 
-» It is forbidden to remove or alter any security device. If any alteration is verified, HORMIX declines any responsibility in eventual damages to 
people or objects. 
-» Any electronic work should be done by qualified personnel only. 
-» Perform the maintenance recommended in this manual and respect its regularity. 
-» When cleaning or performing maintenance on the machine; disconnect it from the power supply. 
-» Never operate the machine under the influence of alcohol, drugs or medication that might influence physical capacity. 
 

3 – TECHNICAL FEATURES 

Model 

Bet. 160 Est. 

Ele. 0.75 Hp 

Bet. 160 Ref. Ele 0.75 

Hp 

Bet. 180 Est. Ele. 

0.75 Hp 

Bet. 180 Est. Gas. 

6 Hp 

Bet. 180 Ref. Ele. 

0.75 Hp 

Bet. 180 Ref. Gas.  

6 Hp 

Bucket Capacity (L) 

160 

160 

180 

180 

180 

180 

Mixing Capacity (L) 

140 

140 

155 

155 

155 

155 

Bucket rotation (r/min) 

27 

27 

27 

27 

27 

27 

Engine Power (KW) 

0.55 

0.55 

0.55 

4.47 

0.55 

4.7 

Electrical Current 

U (V)220 

U (V)220 

U (V)220 

Unleaded Gasoline 

U (V)220 

Unleaded Gasoline 

Net weight (Kg) 

82 

88 

83 

91 

89 

97 

Noise (dB) 

97 

97 

97 

106.2 

97 

105.6 

Size (mm) 

1400x750x1295 

1400x750x1295 

1400x750x1310 

1400x750x1310 

1400x750x1310 

1400x750x1310 

 

4 – STORAGE / MOVEMENT AND TRANSPORT INSTRUCTIONS 

-» 

HORMIX

  concrete  mixers  have  the  possibility  to  be  stored  overlapped,  for  this  they  are  equipped  with  a  rabbet  device  of  the  axle  of  the 

superior concrete mixer in the back support of the inferior concrete mixer. The setting is made with a screw and a nut that fastens the superior 
concrete mixers’ foot base to the inferior concrete mixer. 

NB – The overlapping should not exceed more than two concrete mixers.   
-» The movement of the concrete mixer is made by the rear wheels, having to raise the front support.  The concrete mixer has a handle in the 
front support to facilitate the movement. 
NB – Overlapped concrete mixers should not be moved. 
-» The transport of concrete mixers should be done with the concrete mixer in the normal position of functioning. 
 

5 – STARTING-UP INSTRUCTIONS  
5.1 – Starting-up 

-» Install the concrete mixer in a flat zone with sufficient space to make its load and unload. 
-» To connect this machine to electricity it is obligatory to: 
The energy plug be compatible with the machine connection 
The cable used must have three conductors (Phase, Neutral and Land) with a minimum section of 2.5 mm

2  

The net tension should be 230V 50Hz 

Have  protection  against  short-circuits  of  10A  installed  in  the  machines’  supply  board.  It  should  also  exist  a  differential  protection, 
which caliber must be defined by the technician responsible for installation.   
 

COMBUSTION ENGINE 

-» See engine Instructions Manual 

NB

 Always keep the engine lid open whilst in function. 

 

5.2 – Use 

1

st 

 - Start the concrete mixer by turning the switch on. 

2

nd

 - Tilt the drum to the desired angle (this movement is done by pressing the nailing pedal and turning the wheel).  

3

rd

 - Full the drum with the components to manufacture concrete in the following order: 

½ of the water  

 ½ of the sand 

 All the cement  

 Remaining sand  

 Remaining water  

 Additives  

4

th

 - Once the concrete is done, tilt the drum in order to pour the mortar.

 

5

th

 - Turn the switch off once the concrete has been made. 

Содержание BET 160 EST ELE 0.75 HP

Страница 1: ...T 160 REF ELE 0 75HP BET 180 EST RED GAS 6 0 HP BET 180 EST ELE 0 75 HP BET 180 REF ELE 0 75 HP BET 180 EST GAS 6 HP BET 180 REF GAS 6 0 HP P E F GB 7 10 11 13 14 15 16 17 Rua Direita 171 3810 568 NAR...

Страница 2: ...engine instructions manual which is supplied with the machine Designa o Designation Designation Caracter sticas T cnicas Caract ristiques techniques Characteristic Tecnic X1 Ficha macho monof sica 2P...

Страница 3: ...EIRA 160 180 HORMIGONERA 160 180 BETONNIERE 160 180 CONCRET MIXER 160 180 BETONEIRA 160 180 COM REDU O HORMIGONERA 160 180 CON REDUCCI N BETONNIERE 160 180 AVEC R DUCTION CONCRET MIXER 160 180 WITH RE...

Страница 4: ...ON DE PINHAO 160 180 PROTECTION OF PINHAO 160 180 PT 1 039 2 15 0 21 1 POLIE DA BETETONEIRA B1 POLIA DE LA HORMIGONERA B1 POULIE DE BETONNIEREB1 PULLEY FOR CONCRET MIXER B1 PT 2 022 1 11 0 23 1 CORREI...

Страница 5: ...5 Rota o do Balde r min 27 27 27 27 27 27 Pot ncia do Motor KW 0 55 0 55 0 55 4 47 0 55 4 57 Alimenta o U V 220 U V 220 U V 220 Gasolina s Chumbo U V 220 Gasolina s Chumbo Peso Liquido Kg 82 88 83 91...

Страница 6: ...de corrente interrompida Combust vel n o chega ao motor Desconectar a ficha da m quina e verificar se existe corrente de alimenta o Verificar a exist ncia de danos no cabo de liga o na ficha ou na li...

Страница 7: ...el Motor 0 55 0 55 0 55 4 47 0 55 4 47 Alimentaci n U V 220 U V 220 U V 220 Gasolina s Chumbo U V 220 Gasolina s Chumbo Peso Liquido 82 88 83 91 89 97 Ruido 97 97 97 106 2 97 105 6 Dimensiones 1400x75...

Страница 8: ...corriente el ctrica Combustible insuficiente para el motor Desconectar la ficha de la m quina y verificar si existe corriente el ctrica Verificar la existencia de da os en el cable de conexi n en el...

Страница 9: ...180 Ref Gas 6 Hp Capacit de la Cuve L 160 160 180 180 180 180 Capacit de Malaxage L 140 140 155 155 155 155 Rotation de la Cuve r min 27 27 27 27 27 27 Puissance du Moteur KW 0 55 0 55 0 55 4 47 0 55...

Страница 10: ...r l branchement de la prise Le volante ne tourne pas ou tourne difficilement Manque de lubrifiant M trez quelques go tiez d huile sur de flasque arri re de l trier Graissez le flasque ant rieur de l t...

Страница 11: ...0 55 4 47 0 55 4 7 Electrical Current U V 220 U V 220 U V 220 Unleaded Gasoline U V 220 Unleaded Gasoline Net weight Kg 82 88 83 91 89 97 Noise dB 97 97 97 106 2 97 105 6 Size mm 1400x750x1295 1400x7...

Страница 12: ...rrupted Disconnect the machines plug and verify if there is electrical current Verify the existence of any damage in the cable linking the plug or the plug linking The wheel does not turn or turns wit...

Страница 13: ...13 NOTAS ANOTATIONES ANOTATIONS ANNOTATIONS...

Страница 14: ...ada pela Dierectiva UE 2017 2102 Est en conformidade com las exig ncias b sicas de la Directiva de la CE sobre m quias Directiva 2006 42 CE y la correspondiente transposici n a ley nacional e a n seg...

Отзывы: