Drill the hole for the hose to tank fitting
(22mm
on drill bit) above your high water level. Se-
cure the hose to the fitting using the hose clip. Securely fix the tank fitting into the trough.
Position the control box near to your water trough. Run the hose and lead back to the box
from the water source. Use the tie wraps to secure the lead along the length of the hose if
desired. Connect to the right two terminals (brown wire to
red terminal and blue wire to black terminal).
TIP : Position the trough so that the control box can be
placed behind a fence, protecting it from the animal.
The float switch turns off the pump as the water rises and the switch hinges upwards. Drill
the hole at 16mm. The switch should be positioned so that the high water level required to
turn off the pump
(x)
is below the incoming water pipe
(y).
Connect the switch wires to the
left two terminals on the front of the control box (not positive/negative specific).
Float switch
Connect the pump to the control box
Connect the hose to the tank
10
9
3
(x)
(y)
5