background image

 

25

 

3.4.5 Airflow requirements 

Fuel cell system requires airflow for reaction oxidant as well as cooling. Figure 3.4.5 
below shows the estimated airflow requirements of the H-500XP at different power 
outputs.
Slight contaminant level in the operating environment has insignificant effect on the 
H-500XP performance over the full product lifetime. Exposure to high level of 
contamination in the operating environment will lead to a drop in performance drop, 
which may or may not be recoverable. If the operating environment is expected to 
be very dusty, filter for the oxidant and cooling air may be required. 

Figure 3.4.5 Air

ow curve for H-500XP  system  

3.4.6 Ambient temperature 

One factor that affects the H-500XP performance is ambient temperature. Higher 
temperature leads to the drying up of the proton exchange membranes inside the 
fuel cell stack, reducing proton conductivity and consequently the power output of 
the fuel cell. 
The H-500XP can deliver its rated performance when operating at ambient 
temperature ranging 0-35

°

C* and a relative humidity range of 10-90%. At a given 

environment temperature, the H-500XP performance  increases  with  a higher  level 
of relative humidity.   

Содержание H-500XP

Страница 1: ...1 Date 2013 12 16 Item Number H 500XP Version 20131216 Manual H 500XP Fuel Cell System User ...

Страница 2: ...2 Revision History Release No Date Revised by Revision Description Rev 0 12 16 13 Jason User s Manual draft ...

Страница 3: ...priately tamper with the fuel cell Operate the fuel cell with a controller not designed and built by Horizon for the specific fuel cell Operate the fuel cell with valves and blowers that are not provided by Horizon for the specified fuel cell and controller Disassemble the fuel cell Disassemble the controller Operating the fuel cell and controller that is no that is not in the setup and or specifi...

Страница 4: ...4 Table of Content 1 0 Safety 6 2 0 Part list 12 3 0 General information 18 4 0 System set up 27 5 0 Software 42 6 0 Maintenance 47 7 0 Troubleshooting 50 ...

Страница 5: ... by which the electricity will be generated Humidification A process to humidify the proton exchange membranes for optimal performance Blower Fans attached to fuel cell stack to supply cooling air and process air Purging valve Excess water and hydrogen will be dispelled from the fuel cell flow channels via purge valve SCU Short circuit unit the short circuit will be controlled for good performance...

Страница 6: ...6 1 0 SAFETY ...

Страница 7: ... ignition away from hydrogen This unit uses hydrogen fuel Hydrogen is a colorless odorless and flammable substance It is highly combustible in the presence of oxygen and burns with a colorless flame Leaking gas may be hot and pose a burn danger Stop the flow of gas if you are not in danger and use water to cool the area If fire occurs do not attempt to extinguish flames allow the fire to burn out ...

Страница 8: ...ections and non metal seals such as gaskets O rings pipe thread compounds and packings present potential leakage or permeation sites Furthermore hydrogen s small molecule size results in high buoyancy and diffusivity so leaked hydrogen will rise and become diluted quickly Constant exposure to hydrogen causes hydrogen embrittlement in many materials The mechanisms that cause hydrogen embrittlement ...

Страница 9: ... carry further WARNING A mixture of hydrogen and air is potentially flammable and explosive and can be ignited by a spark or a hot surface As in the presence of any fuel all sources of ignition including smoking are not permitted in the vicinity of the system WARNING Keep all sources of ignition away Smoking is not permitted in the vicinity of the H 500XP 1 6 Oxygen Depletion Oxygen is a colorless...

Страница 10: ...mize conductivity Avoid contact with surfaces that are in contact with water or gases Do not operate or store in wet or damp conditions Never use damaged extension cords H 500XP generates up to 28 8 VDC open circuit voltage This voltage decreases as current is drawn from the module This voltage is exposed at the output power connections These low voltages may constitute a shock hazard and can dama...

Страница 11: ...elets and watches may concentrate an electric current when it comes into contact with charged components or when a shock passes through the human body Accordingly no jewellery should be worn near H 500XP 1 9 High Temperature The fuel cell stack is designed to operate above 60ºC sometimes At this operating temperature the air exhaust stream temperature can reach 55ºC and the cooling air stream can ...

Страница 12: ...12 2 0 PART LIST ...

Страница 13: ...ack holder It helps to fix the fuel cell stack on the place you want There are 4 in the package As showed on stack picture above each side left or right can place 2 NOTE Please use bolts provided together with spring washer Do not over tighten The use of wrong screw length will damage the stack With innovative materials the H 500XP achieved 500W power output with more efficiency comparing to stand...

Страница 14: ...n off For SCU Please refer to Terminology It is the connector which connect startup ba ery to the controller 8 Start up battery connector 6 LCD display It displays the system status current voltage temperature etc Please refer to trouble shooting section for more details Power supply for hydrogen sensor Please attached this wire to your on board battery 12V to power the hydrogen sensor ...

Страница 15: ...he maximum voltage of the fuel cell is 48V so size your ultra capacitors accordingly 11 Ultra capacitor bank Optional The DC DC will regulate the output voltage for the controller It can step down the stack voltage 15V to 28 8V to 12V for the fuel cell controller and other peripheral parts 10 DC DC converter Optional 9 Ambient temperature sensor It senses the ambient temperature The sensor should ...

Страница 16: ...tack and all peripheral parts to perform at its optimal condition It has the following features Control Stack temperature Control Stack purge rate Monitoring stack current and voltage Monitoring H2 concentration H2 sensor needed Protect stack from possible failures like stack low voltage over current over temperature Control Hydrogen supply and shut off RS232 Communication with computer 13 System ...

Страница 17: ...ack Temperature Sensor Grey 3 4 Ambient Temperature Sensor Red Black 5 6 Blowers Red 5 ve Black 6 ve Black 7 8 Hydrogen Purge Valve Black 7 ve Black 8 ve Yellow 9 10 Hydrogen Supply Valve Yellow 9 ve Yellow 10 ve Blue 11 12 Short Circuit Switch Red Black 13 14 N A Black 15 N A Black 16 Blower PWM Table 2 1 Controller Connector ...

Страница 18: ...18 3 0 GENERAL INFORMATION ...

Страница 19: ...19 3 0 GENERAL INFORMATION Figure 3 1 1 Views and dimensions of H 500XP stack Figure3 1 2 Views and dimensions of controller 3 1 Dimensions 264 130 140 79 117 ...

Страница 20: ...re 5 35 C Humidification Self humidified Relative humidity 10 95 RH non condensing Monitoring RS232 System status Historical data Chart 3 2 General Specifica on of H 500XP 3 2 General specification Type of fuel cell Number of cells Mounting Peak power DC voltage Reactants Composition H2 pressure Max stack temperature Cooling Start up battery PEM 30 4 x M6 600W 15 28 8V Hydrogen and Air 99 99 dry H2...

Страница 21: ...21 3 3 Electric Circuit Diagram Figure 3 3 Electric Circuit Diagram for H 500 0XP Please refer to section 2 0 for more details of each part ...

Страница 22: ...system to system variability bands of the fuel cell operating at normal room temperature Nominal operating conditions are as follows Steady state operation constant voltage mode Stack oxidant supply 18 24 C 25 35 RH low levels of common urban pollutants such as nitrogen oxides and sculpture oxides Anode dead ended with adequate purge controlled by HORIZON controller 0 5 bar hydrogen inlet pressure...

Страница 23: ... or operating for significant periods of time below optimal ambient temperature High operating temperatures operating for significant periods of time above optimal ambient temperature Contaminants in the coolant oxidant air Contaminants in the fuel Open storage When the stack is stored over a long period of time in a dry condition 3 4 3 Peak power output The H 500XP can deliver a peak power output...

Страница 24: ...owing formula is used to calculate the system efficiency Figure 3 4 4 Energy content of 1 kg hydrogen 120 1 MJ LHV 33 3 kWh 1000 2 x 22 4 L mol hydrogen generates 33 3kWh energy 1L min hydrogen generate 178 393W power Take 196 27W point for example the hydrogen consump on is 2 218 L min Therefore this amount of hydrogen could generate2 218 x 178 393 395 67W power Then the system efficiency is 196 27...

Страница 25: ...le If the operating environment is expected to be very dusty filter for the oxidant and cooling air may be required Figure 3 4 5 Airflow curve for H 500XP system 3 4 6 Ambient temperature One factor that affects the H 500XP performance is ambient temperature Higher temperature leads to the drying up of the proton exchange membranes inside the fuel cell stack reducing proton conductivity and consequ...

Страница 26: ...z Reportable parameters Name Data Range Resolution Baud rate Frequency Hz Fuel Cell Stack Voltage 15 30V 0 3V 9600 1k Fuel Cell Stack Current 0 60A 0 3A 9600 1k Fuel Cell Power 0 1500W 1W 9600 1k Fuel Cell Stack Temperature 0 70 0 5C 9600 1k Battery Voltage 11 14V 0 2V 9600 1k Table 3 5 RS232 data and format 3 5 Control and Communication ...

Страница 27: ...27 4 0 SYSTEM SET UP ...

Страница 28: ...o the controller before all parts are properly connected 4 1 Setup gas line to the stack Since H 5000XP stack has two hydrogen inlet port and two outlet port therefore a proper gas line need to be connected to make the system work as designed please DO NOT mismatch hydrogen inlet and outlet port which will result in stack under performance and possible damage Please refer to the label on the stack...

Страница 29: ...WARNING Do not place anything in front of or back from the stack which may block off the air flow Step 3 Connect the gas line finished in step 1 to stack hydrogen outlet port as showed in fig 4 3 4 4 Figure 4 5 Step 4 Connect the hydrogen purge valve to the hydrogen outlet gas line please pay attention to the flow direction on the valve body as showed from fig 4 5 to 4 8 ...

Страница 30: ...away from the stack it is recommended that keep the purge line at the stack fan side as the air will blow purged hydrogen away It is strictly prohibited that e n i l e g r u p e h t e v a e l hydrogen canister e r e h p s o m t a o T e v l a v e g r u P Hydrogen supply valve From Figure 4 7 Supply valve From hydrogen canister To H 500XP Purge valve From H 500XP To atmosphere Please avoid positioni...

Страница 31: ...31 4 2 Setup controller Figure 4 9 Step 5 Connect control signal connector to the stack as showed in fig 4 9 Figure 4 10 Step 6 Connect power cord connector to the stack as showed in fig 4 10 ...

Страница 32: ...ed in fig 4 11 A fuse is to be installed on the positive side of the capacitor bank not provided This fuse rating will varies from team to team and must be according the Chapter 1 Shell Eco Marathon Rules Step 8 Connect DC DC connector to the DC DC convertor as showed in fig 4 12 Figure 4 12 ...

Страница 33: ...gure 4 13 Step 9 Connect hydrogen sensor to the hydrogen sensor connector as showed in fig 4 13 Please note that some application will not require this component and system will still work without this part ...

Страница 34: ...nect LCD display to the controller LCD connector please note system could run without this part as showed in fig 4 14 Connect the hydrogen sensor to on board battery to power the safety circuit as showed in fig 4 15 Figure 4 15 ...

Страница 35: ...e First connect the cable to the start up battery Then plug the cable connector to the controller as showed in fig 4 16 NOTE It is NOT suggested to plug the battery cable to the controller BEFORE it connects to the battery as showed in fig 4 17 Figure 4 17 Warning Please observe the polarity of the wire Wrong polarity will damage the controller ...

Страница 36: ...ect rs232 to your computer to record system operation data as showed in fig 4 18 Please refer to the software section for more details Figure 4 19 Step 13 Please make sure the emergency stop switch is at off position otherwise the system is unable to start ...

Страница 37: ...37 Step 13 To turn on Push the button as showed in fig 4 20 To turn off Wheel the button till it is up as showed in fig 4 21 Figure 4 20 Figure 4 21 ...

Страница 38: ...e clamp is NOT suggested to use for connecting You may find other tools to make the connection more reliable This way is only for example A fuse is to be installed on the positive side of the fuel cell terminal This fuse rating will varies from team to team and must be according the Chapter 1 Shell Eco Marathon Rules Figure 4 23 Figure 4 24 ...

Страница 39: ...4 25 Step 15 Please find the tube to the Hydrogen supply valve connect it to the regulator Then set the regulator value to operating pressure 0 5bar 15SLPM NOTE The type of the regulator used for example may be different from yours Warning Make sure the pressure of the hydrogen supply is maintained at 0 5 barg This is critical especially during high flow rate at higher power output ...

Страница 40: ...t the system by long press the button 3 seconds Come to booting up phase system beeps for a short moment flash the blue LED display Horizon Fuel Cell on the LCD Come to running phase the blue LED will light on the LCD displays E for ambient temperature B for battery voltage T for stack temperature I for stack current U for stack voltage Figure 4 29 Figure 4 30 ...

Страница 41: ... low and the system will shut off for protection For more please refer to troubleshooting section 4 4 System manual shut off Figure 4 32 Step 18 Long press the button 3 seconds System beeps and LCD displays SYSTEM OFF FOR MANUAL TURN OFF WARNING Do not attempt to let outside load run out all the energy from fuel cell or other ways may cause system shut down by error protection if you want to turn ...

Страница 42: ... 42 5 0 SOFTWARE ...

Страница 43: ...rrent Monitoring e Stack Power Monitoring 2 Real time Curves a Ambient Temperature Curve b Stack Temperature Curve c Stack Voltage Curve d Stack Current Curve e Stack Power Curve f Battery Voltage Curve 3 History Display a Display Result b Save to File 5 2 Environment Hardware Environment 1 Desktop or Laptop with Serial Port 2 Serial Cable RS232 Or 1 Desktop or Laptop with USB 2 USB To RS232 Cable...

Страница 44: ...to record data or not 4 Set recording Period Default is 1s Run Stop 1 After the configuration press the RUN button on the top left corner to run the program 2 Press STOP button on the top right corner to stop the program Monitor Panel 1 Ambient Temperature Stack Temperature Voltage Current Power will display as meter and number on this panel Figure 5 4 Monitor panel Figure 5 1 Configuration Figure...

Страница 45: ...age will display as real time curves on this panel History Panel 1 User select the time from the pull down list 2 Press the DISPLAY RESULT button the history data will display in the result records table 3 Press SAVE TO FILE button the results will save in the data directory as an EXCEL file ...

Страница 46: ...ory panel 5 5 Error Information 1 Connection Timeout Error c Phenomenon A dialogue window will pop up as follow Figure 5 10 Monitor panel d Description ECO Marathon Serial Port Monitor lost connection to the system 1 2 3 ...

Страница 47: ... 47 6 0 MAINTENANCE ...

Страница 48: ...the gas port marked H2 Input and another one to the H2 Output port 2 Fill a syringe with pure water distilled and connect it to the hose attached to the H2 Input port 3 Inject pure water into the stack until you see water coming out of the hose connected to the H2 Output port Keep the water inside the stack for about 5 minutes Now disconnect the syringe and leave the water in the two hoses 4 Purge...

Страница 49: ...elow 45 C the whole system will stop operation in order to protect the stack So in order to make it work well the fuel cell stack must be maintained lower than 45 C before operate the on off switch WARNING The stack must be standing on the clear plastic feet WARNING Before the load is connected turn on the blower controller Otherwise the load will not run During the operation process do not turn o...

Страница 50: ... 50 7 0 TROUBLESHOOTING ...

Страница 51: ... is too low Shut down 4 Starting up System off H2 High Red flashing Long beep Hydrogen leaks Shut down 5 Running E B T U I Green light on NONE Normal Running 6 Running System off FC Voltage Low Red flashing Long beep Stack voltage is too low Shut down 7 Running System off H2 High Red flashing Long beep Hydrogen leaks Shut down 8 Running System off Current High Red flashing Long beep Stack current ...

Страница 52: ...ny charge left 1 Disconnect the external power source 2 Using a multimeter take a reading of the positive and negative connection points on the external power connectors to the controller 3 If the power is 13 5V then the power is not coming through to be able to power the controller blowers and valves 4 Change or recharge your power supply and check the voltage that it meets the fuel cell voltage ...

Страница 53: ...tage is not dropping then contact support horizonfuelcell com with the diagnostic SCU not operational with the controller number Check the blower controller Before the load is connected turn on the blower controller Otherwise the load will not run During the operation process do not turn off the blower controller ...