Horizon Fitness H-12 Скачать руководство пользователя страница 2

 

 

Disclaimer  

 
This manual incorporates safety guidelines and recommendations. However, it is not 
intended to cover all situations.  It is the responsibility of the customer to meet all local 
safety requirements and to ensure safety during operation, maintenance and storage of 
the H-12 stack.    
 
Although all efforts have been made to ensure the accuracy and completeness of the 
information contained in this document, Horizon reserves the right to change the 
information at any time and assumes no liability for its accuracy.    
 

Actions that will void the fuel cell warranty: 
 

 Attempt, 

under 

any 

circumstance, 

to disassemble or inappropriately 

tamper with the fuel cell.  

 

Operate the fuel cell with valves and blowers that are not provided by 
Horizon for the specified fuel cell and controller. 

 

 

Disassemble the fuel cell. 

 

Operate the fuel cell that is not in the setup and/or specified in the user 
manual provide for the specific product. 

 
 

 

 

 
 
 
 
 
 

 
 
 

IMPORTANT

 

 
 

In order for the warranty to come into effect the stack must be registered on the 

Horizon Warranty Page at: 

www.horizonfuelcell.com/warranty.htm

 

 

 
 

Do not attempt, under any circumstance, to disassemble or 

inappropriately tamper with the fuel cell. There will be no 

returns, refunds or exchanges should disassembly or 

tampering occur. If you have questions or need help with 

regards to the fuel cell and its technology contact -

[email protected].

 

Содержание H-12

Страница 1: ...1 Think Big Start Small H 12 Fuel Cell Stack User Manual Updated 08 Dec 2011 H 12_UM_ V2 4_EN...

Страница 2: ...tance to disassemble or inappropriately tamper with the fuel cell Operate the fuel cell with valves and blowers that are not provided by Horizon for the specified fuel cell and controller Disassemble...

Страница 3: ...Stack and System Component Information 10 4 Technical Specification 11 5 System Performance Curves 12 6 System Set Up 13 6 1 Operating instructions 13 6 2 Simplified Drawings of HFCT Measurement Stand...

Страница 4: ...s when the fuel cell stack is energised Do not dismantle the system Contact Horizon if you have any concerns about operation 1 2 Using Hydrogen WARNING FIRE OR EXPLOSION Keep all sources of ignition a...

Страница 5: ...any materials considered airtight Fuel lines non welded connections and non metal seals such as gaskets O rings pipe thread compounds and packings present potential leakage or permeation sites Further...

Страница 6: ...ce As in the presence of any fuel all sources of ignition including smoking are not permitted in the vicinity of the stack WARNING Keep all sources of ignition away Smoking is not permitted in the vic...

Страница 7: ...o not touch individual fuel cells cell voltage monitoring equipment or electrical components WARNING Do not touch fuel cells cell voltage monitoring equipment or electrical components Electronic compo...

Страница 8: ...reach 55 C and the cooling air stream can reach 17 C above ambient conditions These temperatures are sufficient to cause burns or severe discomfort Accordingly avoid contact with the fuel cell stack o...

Страница 9: ...n the fuel cell the reactants are air and hydrogen by which the electricity will be generated Humidification humidity that the fuel cells need for running Blower supply air to the fuel cells and meanw...

Страница 10: ...fuel cells arranged along an axis generally parallel to cell thickness with electrically conductive separator plates between each pair of cells 3 Tube It is used for connecting the pressure regulator...

Страница 11: ...emperature 55 C H2 Pressure 0 45 0 55bar Hydrogen purity 99 995 dry H2 Humidification self humidified Cooling Air integrated cooling fan Weight with fan casing 275 grams 30 grams Dimension 7 5cmX4 7cm...

Страница 12: ...12 5 Standard System Performance Curves...

Страница 13: ...quired to be more than 2mm The input pressure to the stack is required to be 0 45 0 55Bar 2 Disconnect the hydrogen tube from the hydrogen input immediately after the fuel cell stack is shut down Sinc...

Страница 14: ...Disconnect the hydrogen tube from the hydrogen input immediately after the fuel cell stack is shut down Since hydrogen gas can leak into the fuel cell and destroy the stack Step 4 Disconnect the red p...

Страница 15: ...15 6 2 Simplified Drawings of HFCT Measurement Stand Power V x A...

Страница 16: ...then connect it to the hose attached to the stack 3 Inject distilled or purified water into the stack until you see water coming out of another port see picture A below for reference Keep the water in...

Страница 17: ...t Horizon Fuel Cell Technologies for support The open voltage no load stack voltage is less than 9 1V 1 Inject water into the stack see Storage and re use for details And then re test open voltage Not...