15
2. Operation Procedure
2-1 Binding Operation Procedure
13.
Adjust the nipper opening to the same as
the tape width by turning the tape guide
adjusting knob.
14.
Position the tape between the tape align-
ment guides. Place the sensor cover over
the sensor. The start lamp will light.
15.
Press the start button.
- The clamper moves to the right, applying
glue to the spine of the book block, then
stops at the home position (above the
nipper).
- The nipper forms the square spine of the
book.
- The nipper moves down and the clamper
open button lights after the set nipping
time has elapsed.
16.
Press the clamper open button.
- The clamper opens, the light in the
clamper open button goes out, and the
reset lamp lights.
17.
Remove the bound book by drawing it out
to the right.
NOTE
- The nipper is reset automatically by tilting
the guard plate.
Sensor Cover
Tape Guide
Sensor
Tape Guide Adjusting Knob
Start Lamp
Reset Lamp
Start Button
Bound Book
Guard Plate
12.
Check that sensor cover is open.