background image

 

4

CHAPTER 2: ENGINEERING MODE 

2.1 Engineering Mode

   

 

1)  To enter Engineering Mode, press & hold the INCLINE UP and SPEED DOWN

 

keys at the same time for 

3-5 seconds until Engineering Menu appears on the display. 

 

2)    Use the INCLINE or SPEED UP and DOWN keys to scroll through a list of parameters.   

   

3)    Press ENTER to enter a parameter setting.     

 

4)    Use the INCLINE or SPEED UP and DOWN keys to change the parameter.     

 

5)    Press the ENTER key to save the change to the parameter.     

 

6)  Press and hold the STOP key to exit Engineering Mode and return to normal operation.     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 622T

Страница 1: ...1 Horizon Fitness 622T Service Manual...

Страница 2: ...RAM 3 1 Electrical Diagram 6 CHAPTER 4 TROUBLESHOOTING 4 1 Troubleshooting No Power to the Console 7 4 2 Troubleshooting Keypads Not Responding 9 4 3 Troubleshooting No Console Response 10 4 4 Trouble...

Страница 3: ...3 CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Serial Number Location...

Страница 4: ...ring Menu appears on the display 2 Use the INCLINE or SPEED UP and DOWN keys to scroll through a list of parameters 3 Press ENTER to enter a parameter setting 4 Use the INCLINE or SPEED UP and DOWN ke...

Страница 5: ...mo off 0 in the TIME window Use the START key to select unit 1 KM 0 Mile in the DISTANCE window ENG 4 Information Accumulated Time and Distance Press and hold the START key for 5 seconds to clear all...

Страница 6: ...6 CHAPTER 3 ELECTRICAL DIAGRAM 3 1 Electrical Diagram...

Страница 7: ...Solution 1 Check to see if the power switch is lit If it is not try a different outlet a If the power switch still does not light up with a known good outlet replace the power switch 2 Check to see i...

Страница 8: ...ltage between the GND pin Pins 4 5 and the 15V Pin Pins 7 8 DC output is normally around 15VDC If there is no output replace the MCB b If output is around 15VDC check the console cable for pinches or...

Страница 9: ...Mode a Use the SPEED OR INCLINE UP or DOWN key to scroll to ENG0 and press ENTER b Test each of the keypads using Display Test The console should chime as each key is pressed 2 If any keypads are not...

Страница 10: ...dows TIME and DISTANCE changes the console is ok If the data does not change replace the UCB 3 Turn off the power switch and open the upper motor cover Remove the red black wires coming from the motor...

Страница 11: ...pads as outlined in Section 4 2 2 Enter Engineering Mode See Section 2 1 and scroll to ENG 1 Hardware Test Press the ENTER key and then the START key a Press the INCLINE UP and DOWN keys b If beeps ca...

Страница 12: ...PH P2 speed range of 3 5 MPH P3 speed range of 5 8 MPH P4 speed range of 8 10 MPH Figure A a Upon successful calibration the treadmill will beep several times The console will automatically exit Engin...

Страница 13: ...incline motor is missing washers or needs lubrication Solution 1 This noise is from the roller or running belt a If this is a new unit some noise is normal as the running belt forms around the roller...

Страница 14: ...he running deck is tightly attached to the frame b Check the deck shocks for deterioration or crumbling Replace if needed c Check to see if the air shock is making this noise lubricate or replace if n...

Страница 15: ...aker wire are defective 7 There is a grounding issue with the earphones or console Solution 1 One of the speaker boards has a bad connection or is faulty a Check the connection of the wires going from...

Страница 16: ...he IPod dock at the console c Replace the IPod dock 5 Speakers are not getting a clear signal through the speaker wires a Check the speaker wire connections b Check for any kinks or cuts in the speake...