4
Check the power supply voltage.
If the required tolerance of the power supply voltage cannot be maintained with a
mains transformer, an AC voltage regulator must be used.
Proceed as follows to switch the electrics on:
1
Remove the
cover.
Proceed as follows to remove the cover:
2
Feed the cable through the screw connector in the cover to the terminal strip.
3
Connect the electrics in accordance with the circuit diagram.
Hint:
The circuit diagram
is located on the printed circuit board cover
ATTENTION
Malfunction due to incorrect zero potential!
If the linear actuator is electrically supplied by signal generators with different zero
potentials, this may cause incorrect dynamic performance.
•
Ensure that the zero potentials are correctly used.
4
Tighten the screw connections.
Diagram 8