Hopkins BLAZER CWL622 Скачать руководство пользователя страница 1

CWL622 

 WMS & FLOOD LIGHT KIT 

 OWNER

S MANUAL 

BLAZER-INTERNATIONAL.COM

1-800-835-0129

Page 1 of 12

Patent Pending 

© Copyright 2019

HOPKINS MANUFACTURING CORPORATION

428 PEYTON ST., EMPORIA, KS 66801

www.HopkinsMfg.com | 1-620-342-7320

Overview

This product is a professional, remote control, wire management system. The WMS is designed for 
operating accessories (including lights, horns, warning beacons, etc.) typically used on work or off-road 
vehicles (trucks, jeeps, ATV/UTV, boats, heavy equipment, farm equipment, etc.). The unit works on 12V 
DC and provides output to four terminals which are protected by a 40A fuse.

Please note that the remote control can be clipped onto a visor, or conveniently stored within the 
vehicle for easy access. It uses a 12V, A23 size alkaline battery included with the kit. If the 
remote control is lost or broken – it can be replaced and the new remote “paired” with the existing 
WMS.

Together with two flood lights, this kit will allow you to add lights for off-road in under one hour.

Installation

1. 

Please read these instructions carefully before installing this product. It is recommended to 
consult a professional installer to prevent damage to vehicle and/or system.

2. 

Do not connect to 24V DC or higher voltage system, as this product is designed for a 12V DC 
battery system. In case you have a larger than 12V DC system, check vehicle owner’s manual to 
determine if a 12V DC output is available and how to connect in order to use it safely, otherwise, 
the product will be damaged.

3. 

Find a suitable flat surface near the battery, clean the surface free of dirt and oil and then affix the 
unit using provided adhesive strips and/or mounting holes.

4. 

Remove the 40A fuse from the holder and disconnect the vehicle battery.

5. 

Securely attach the positive (red) cable of the WMS unit to the positive terminal of the battery or 
battery cable and the negative (black) cable of the WMS to the negative battery cable or chassis.

6. 

Identify the areas where you would like to mount the LED lights and using the included hardware, 
securely mount the lamp to your vehicle.

7. 

Securely attach the red wire of the first LED light to the positive terminal (+) of the 2A circuit on 
WMS unit and black (negative) wire to the negative (-) terminal of the circuit. Repeat this step for 
the second work light using the second 2A circuit. If you would like both lights to turn on at the 
same time with one button push, attach both red wires to the 18A terminal’s positive (+) terminal 
and both black wires to the negative (-) terminal.

8. 

Attach the auxiliary lights/equipment following correct polarity on the terminals and not exceeding 
the maximum amperage of the channels. See 

FIG 1 

(on page 2)

9. 

Reconnect battery cables. 

10.  Insert the 40A fuse back into the holder and snap the cover closed.

11.  Test by pressing remote button and checking accessory operation. Remote includes a 12V (A23 

alkaline) battery. Recycle used battery as per local codes.

Содержание BLAZER CWL622

Страница 1: ...s manual to determine if a 12V DC output is available and how to connect in order to use it safely otherwise the product will be damaged 3 Find a suitable flat surface near the battery clean the surface free of dirt and oil and then affix the unit using provided adhesive strips and or mounting holes 4 Remove the 40A fuse from the holder and disconnect the vehicle battery 5 Securely attach the posi...

Страница 2: ... DC 13V Working voltage DC 11 15V Working temperature 0 F 225 F 17 C 107 C Fuse 40A Remote control battery 12V A23 alkaline Low voltage protection circuit 9 8V 0 3V DC with 8 sec delay Thermal shut off temperature 248 F 120 C LED Light Two LED flood lights FIG 1 1 Main Unit 2 Terminals 3 Eyelet for Mounting Installation 4 Fuse Holder 5 Negative Cable 6 Positive Cable FIG 2 1 LED Indicator battery ...

Страница 3: ...essories lights will not come on Check wire polarity for those items Light accessory comes on momentarily That channel is being overloaded Make sure the amperage of the light is less than that stated at the terminal check fuse In case the remote is lost a replacement remote can be paired with the existing module rather than purchasing a new system call customer service at 800 241 3808 for assistan...

Страница 4: ...S SET FORTH FOR AN UNCONTROLLED ENVIRONMENT THIS DEVICE COMPLIES WITH INDUSTRY CANADA LICENSE EXEMPT RSS STANDARD S OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION JS SUBJ...

Страница 5: ... utiliser en toute sécurité à défaut de suivre ces directives le produit pourrait être endommagé 3 Localisez une surface unie appropriée près de la batterie Retirez toute saleté et huile de la surface et fixez l unité en place à l aide des rubans adhésifs inclus ou des orifices de montage 4 Retirez le fusible de 40 ampères du support et débranchez la batterie du véhicule 5 Connectez fermement le c...

Страница 6: ... volts CC Température de fonctionnement 17 C 107 C 0 F 225 F Fusible 40 ampères Pile de contrôle à distance Alcaline A23 de 12 volts Protection contre basse tension de circuit 9 8 volts 03 volts CC avec circuit de temporisation de 8 sec Température de fermeture thermique 120 C 248 F Bar à LED Barre de lumières DEL réflecteur projecteur de 61 cm vous FIG 1 1 Unité principale 2 Bornes 3 Œillet pour ...

Страница 7: ...ment pas Vérifiez la polarité de ces articles Lumière accessoire s allume momentanément Ce canal subit une surcharge Assurez vous que l ampérage de la lumière est inférieur à l ampérage indiqué sur la borne vérifiez le fusible Si le contrôle à distance est perdu il est possible de le remplacer et de le relier au système existant plutôt que d en acheter un nouveau contactez le service à la clientèl...

Страница 8: ...S 102 d Industrie Canada établies pour un environnement non contrôlé Ce produit est conforme aux normes sans licence RSS d Industrie Canada Le fonctionnement est soumis aux conditions suivantes 1 cet appareil ne peut causer d interférences nuisibles et 2 Cet appareil doit accepter toute interférence reçue y compris des interférences qui peuvent provoquer un fonctionnement non désiré Ce produit est...

Страница 9: ...o 3 Localice una superficie plana apropiada cerca de la batería Quite cualquier suciedad y aceite de la superficie y fije la unidad en su lugar utilizando las cintas adhesivas incluidas o los orificios para montaje 4 Quite el fusible de 40 amperios del soporte y desconecte la batería del vehículo 5 Conecte firmemente el cable positivo rojo del sistema con la terminal positiva de la batería o cable...

Страница 10: ...s CC Temperatura de funcionamiento 17 C 107 C 0 F 225 F Fusible 40 amperios Pila de control remoto Alcalina A23 de 12 voltios Protección contra baja voltaje de circuito 9 8 volts 03 voltios CC con retardo de tiempo de 8 seg Temperatura de apagado térmico 120 C 248 F Barra LED Barra de luces LED reflector foco de 61 cm FIG 1 1 Unidad principal 2 Terminales 3 Ojete para instalación 4 Soporte de fusi...

Страница 11: ... Verifique la polaridad de estos artículos Luz accesorio se enciende momentáneamente Este canal está siendo sobrecargado Asegúrese de que el amperaje de la luz sea menor que el amperaje indicado sobre la terminal verifique el fusible Si el control remoto se pierde puede ser reemplazado y puede emparejarlo con el sistema existente en lugar de comprar un sistema nuevo llame al servicio a la clientel...

Страница 12: ...oducto cumple con los estándares exentos de licencia RSS del Ministerio de Industria de Canadá La utilización de este equipo está sujeta a las dos condiciones siguientes 1 este dispositivo no puede causar interferencia dañina y 2 Este dispositivo debe aceptar cualquier interferencia recibida incluida cualquier interferencia que pueda causar un funcionamiento no deseado Este producto cumple con Sec...

Страница 13: ...o or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult ...