Replace the batteries when any of the following happens

• The   

+Lo

  shows

• The display dims

• The display does not light up

BEFORE YOU START

BEFORE YOU START

♥ 

Installing and Replacing the Batteries

1. 

Slide off the battery cover on the back of the unit.

2.

 Install the batteries by matching the correct polarity, as shown below.  

   

 

Always use the correct battery type (2 alkaline AAA size)

3.

 Replace the battery cover.

It is important to set the clock before using your blood pressure monitor 

so that a time stamp can be assigned to each record stored in the memory.  

(The year can be set to anywhere between 2000 and 2050.)

♥ 

Setting the Year, Date, Hour Format, Time,  

    and Measurement Units

1.

 When the unit  is off, press the “SET” button 

once then press “SET” again and hold for 3 
seconds to enter the mode settings.

2.

 The [YEAR] will begin to flash. Press 

“MEM” to advance to the current year.

3.

 Press “SET” when you have reached 

the correct year to save your choice 
and advance to the next step.

4.

 Repeat steps 2 and 3 to set the 

[MONTH] and [DAY].

• If this device will be stored for an extended period of time, please remove the batteries 

in order to avoid corrosion. 

• Used batteries are harmful to the environment, so please dispose of appropriately.  

Remove the old batteries from the device and follow your local recycling guidelines 

• Battery corrosion is not covered under your three year limited warranty.

CAUTION 

!

Содержание 526014

Страница 1: ...BP monitor correctly and safely please read this entire manual thoroughly and keep it for your reference Item 526014 5 Greenwood Place Baltimore MD 21208 1 800 835 1995 FAX 410 484 4036 www hmponline...

Страница 2: ...nts of the Medical Device Directive 93 42 EEC Manufacturer Specifies serial number Type B applied part DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separat...

Страница 3: ...ting CUFF air is exhausting of deflating Time hour minute Currently time Memory If M shows the displayed measurement values is from the memory For instructions refer to Page 9 mmHg Measurement Unit of...

Страница 4: ...etween 2000 and 2050 Setting the Year Date Hour Format Time and Measurement Units 1 When the unit is off press the SET button once then press SET again and hold for 3 seconds to enter the mode setting...

Страница 5: ...heart 5 Position the edge of the cuff about 1 inch from your wrist 6 Fasten the wrist cuff around your wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measurem...

Страница 6: ...d date and time will display alternately The most recent record is shown first Each new measurement is assigned to the first 1 record All other records are pushed back one digit e g 2 becomes 3 and so...

Страница 7: ...inutes after taking a bath or shower Never take a reading while talking or moving your fingers Never take a reading in a very cold environment Never take a reading when you need to use the restroom 1...

Страница 8: ...od pressure in the cycle occurs when the heart relaxes between heartbeats and this is known as diastolic pressure The systolic pressure is the top number in your blood pressure reading and the diastol...

Страница 9: ...dings using the left arm Consult your physician if you think you need to use your right arm instead Whichever arm you use it is important to take your blood pressure using the same arm every time you...

Страница 10: ...formation WARRANTY INFORMATION SPECIFICATIONS For more information about our products please visit our website www hmponline com For customer service please call us at 1 800 835 1995 M F 8 30 AM 5 PM...

Отзывы: