T
ECHNICAL
D
ATA
System 6844(RC) - V03.00
147 / 157
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
11
Technical Data
11.1 Specific Technical Data for 3U / Table-Top / Wall
Technical Data - System 6844(RC) 3U / Table-Top / Wall
Housing construction:
Sheet steel / aluminium, closed
3U and Table-Top with ventilation openings for convec-
tion on top and bottom
Housing measurement:
Dimensions are housing specifically / see
Chapter
1.2.2.1 19 Inch Rack 3U/42HP and 3U/84HP,
1.2.4.1 ½ 19 Inch Table Top Housing 3U/42HP
and
1.2.5.1 ½ 19 Inch Wall Housing 3U/42HP
Housing protection class:
IP20
Protection class:
I, with PE connection. Additional earth screw for cables
up to 16mm
2
Cooling:
Convection
Weight:
Dependent on housing
AC Power Supply
(with Standard Power Supply)
Nominal input voltage:
115 / 230V AC / 47-63Hz
Connection via input connector compliant
with IEC/EN 60320-1/C14 incl. EMI line filter
Current consumption (at nominal values):
approx. 0.7A (115V AC) / 0.4A (230V AC)
Mains failure bridging at nominal load:
> 20msec.
Insulation voltage (EN60950)
Input / Output:
3000V
eff
Output Data (intern only)
Internal nominal output voltage:
5V DC
Nominal output current I
N
0°C .. +55°C:
6A
(U
OUT
= 5V DC)
Efficiency:
> 70%
Function display (Power LED):
LED green
DC Power Supply 24V or 48V (Option)
Nominal input voltage:
24V DC
or 48V DC
110/220V DC
Input voltage range:
18-36V DC or 36-72V DC
100-250V DC
Current consumption (at nominal values):
2.5A
or 1.3A
approx.
0,8 / 0.4A
Mains failure bridging at nominal load:
> 3msec.
> 20msec.
Insulation voltage (EN60950)
Input / Output:
2.000V
eff
3000V
eff
Output Data (intern only)
Internal nominal output voltage:
5V DC
5V DC
Nominal output current I
N
0°C .. +55°C
6A
(U
OUT
= 5V DC)
6A
(U
OUT
= 5V DC)
Efficiency:
> 70%
> 70%
Function display (Power LED)
LED green
LED green