R8LED.09.2014/REV4

25.4mm

(Item 6)

OR

31.8mm

(Item 5)

Head mount

3

4

4

3

2

1

Remote battery using extension cable:

Note:

The R8 lamp includes an ‘energy preserve’ feature whereby the power 

will automatically drop down from mode 3 to mode 2 towards the end 

of the battery discharge cycle (i.e. after approximately 1 hour 30 minutes 

in mode 3 with the 7800mAh battery, depending on conditions).  The 

switch illumination will change from blue to green at this point.  This is 

to prolong the remaining energy within the battery.  If you attempt to 

re-select mode 3 during the energy preserve period the lamp will 

immediately fade back down to mode 2 and block the selection of mode 

3 in order to maximise the remaining battery life.   Operation of the lamp 

then continues with only modes 1 and 2 remaining active with each subsequent press of the 

power button.  Mode 3 is no longer selectable.  This is a deliberate characteristic of the drive 

circuit and should not be interpreted as a malfunction.

The R8 also features a low battery warning mode.  When the battery is almost at the end of it’s 

discharge cycle the lamp will drop down into low power mode, the switch will illuminate red, 

and the lamp will flash twice every 30 seconds to warn you that you are running low on battery 

life.  Once the lamp unit has dropped into low battery mode, no other modes are selectable.  

Pressing the power button will only turn the lamp off or on.

*Although every effort is made to state accurate burn times, battery life is dependant on various factors and 

environmental conditions.  Therefore, actual burn times may vary from those shown.

L

ow battery warning

FITTING INSTRUCTIONS

Handlebar mount

Helmet mount

M

ode 1

850 Lum

en

s

5:30 hrs 

M

ode 2

1450 L

um

en

s

2:45 hrs 

M

ode 3

2200 L

um

en

s

1:30 hrs 

M

ode 1

130 L

um

en

s

35:00 hrs 

M

ode 2

320 L

um

en

s

10:00 hrs 

M

ode 3

Flash mode 

RA

CE SEQUENCE

TR

AIL SEQUENCE

PRESS AND HOLD AT ANY TIME TO TURN OFF

QUICK PRESS:

ON

PRESS AND HOLD:

ON

OFF

OPERATION OF THE LAMP

In order to prevent any malfunction within your Li-Ion battery pack and to preserve the 

capacity as much as possible, there are a number of procedures which must be 

considered when storing your battery pack for long periods while not in use (ie. over the 

summer months).

Storage and transportation:  

Never carry the lighting system by the cable.  This could 

result in damage to the electrical connections and will invalidate your warranty.

Always disconnect the lamp unit from the battery pack when not in use.  When the  lamp 

unit and battery pack are connected there is a small amount of power constantly running 

through the circuit which could – over a period of time – over discharge the battery pack 

resulting in loss of battery function and capacity.  This will also prevent the lamp unit 

accidentally switching on and potentially overheating, which could cause permanent 

damage to the lamp and battery.  In extreme cases, overheating could cause fire and/or 

death.

Storage Temperature:  

The battery pack should be stored within the temperature range 

of -20°C to 25°C in order to preserve cell capacity.  Ideally in a cool, dry room such as a 

cellar or garage.

Over discharging:  

As with most battery cells, Li-Ion cells may discharge if they are not 

used for a long time.  In order to prevent over discharging fully charge the battery pack 

before you store it.  Also, charge the battery pack periodically (ie. once every 3-4 weeks) 

to maintain the voltage between 6.8V to 7.6V.  Over discharging may cause loss of cell 

performance, or damage battery function.

If these few procedures are followed correctly, you can be sure that when the dark nights 

creep back in your HOPE VISION battery pack will be fit and raring to go!

STORAGE AND TRANSPORTATION

DANGER: Use only the 7.4v Li-Ion battery pack supplied with the lighting system.  

Any attempt to use or charge another battery pack may result in explosion and 

serious injury.

The battery charger is designed for indoor use only and should not come into 

contact with water.

The mains socket should be easily accessible.  In the event of any operational error 

the plug should be immediately removed from the mains supply.

The battery charger contains dangerous voltages and the cover should not be 

removed.  Any attempt to open the charger will invalidate the warranty.

NOTE: 

The rechargeable battery pack is supplied with a small charge for testing purposes 

only.  Therefore, it is recommended that the battery pack be fully charged before first use.

To correctly charge the battery pack, ensure these steps are followed in order: 

·  Disconnect the battery pack from the light unit by pulling apart the two mating DC 

connectors.  Always grip the connector heads when disconnecting, not the cables.

·  Plug the charger into the battery pack before connecting it to the mains supply(1).

·  Once the battery pack is connected to the charger it can then be plugged into the 

mains power supply (2).  The charger’s LED indicator will show as red during the charging 

process.  We recommend that the two mating connectors are rotated at this point (3) to 

ensure that a good connection is made between the battery pack and charger, and that 

the LED indicator turns red.

·  When charging is complete, the charger’s LED indicator will turn green.  Disconnect 

from the mains power supply before disconnecting the battery pack from the charger.

NOTE: 

 If you attempt to place the battery pack on charge after only a short period of use 

(ie. with the remaining capacity at around 75% or higher, with four indicators lit on the 

LED display), you may notice that the battery pack will not begin charging.  This is not a 

fault.  It is simply due to the software communication between the battery pack and 

charger.  The charger is looking for a battery voltage of lower than 8v before it will begin 

the charge process.

If this happens, simply connect the battery pack to the lamp unit and run the lamp for a 

short while to further discharge the battery pack.  It will then charge successfully.

Charge Times:

  A fully discharged 7800mAh battery should take approx 9 hours to fully 

recharge.

1

2

3

CHARGING THE BATTERY PACK

Red

LI-ION E.S. BATTERY PACK

The ES (Energy Status) battery pack features a 5 stage fuel gauge.  Press and hold the 

‘TEST’ button to activate the LED display.  This gives a visual indication of the remaining 

capacity within the battery cells.

75% - 100%

50% - 75%

25% - 50%

5% - 25%

Fully discharged.

Charge immediately