10
Installation Instructions
Preparing for Installation
Important! Perform the following steps BEFORE Installation of the monitor.
1.
Ensure that sufficient power is available.
2.
Ensure that sufficient space is available to allow for proper airflow around the
enclosure.
3.
Ensure that the air temperature around the unit (top and bottom) will not ex-
ceed the rated specifications of the unit.
The maximum rated temperature of the HIS-WL17 is 45
°
C (113
°
F).
Also, remember that even though this product is designed to operate
at 45
°
C , the life span of any electronic device is shortened when it is
consistently operated at high temperatures. Therefore it is wise to
take steps to keep the temperature of the ambient air around the unit
as low as possible.
4.
Ensure that the ambient humidity of the air around the unit does not exceed the
rated specifications for the unit
The maximum rated humidity for the HIS-WL17 is 90% non-condensing.
Installation using VESA mounting
All units come standard with a 100mm square VESA mounting pattern with M4
threads (75mm VESA pattern is also available on the NEMA 12 version). If this
mounting method is used, consider the following:
M4 screws should not protrude into the rear cover by more than 1/4”.
The capacity of the arm or mounting plate selected should take into account the
total weight of the monitor and its center of gravity.
For NEMA 4/4X applications, the mounting interface should be properly
sealed to prevent egress of water.