background image

9

3-14

3-15

3-16

Headlight replacement

What to buy

This cleaner uses a 12 volt, wedge base
type 912 bulb, Hoover 

part No. 27313101.

Reattaching filter door

The filter door is designed with a
“break-away” feature which allows it to
snap free if it is pushed open too far.

To reattach, align hinges (O) of cover
with slots on sides of filter area.

Press door back into place.

Check brush roll
channels

Because your cleaner picks up so well,
we strongly recommend you check for
debris accumulation in the channels
next to the brush roll 

when you check

the filters. 

Removing this debris will

help maintain your cleaner’s excellent
pick up and suction. Remove debris as
follows:

Disconnect cleaner from electrical
outlet.

Check for debris accumulation by
removing bottom plate (Fig. 3-18) and
looking in the channels next to the brush
roll (Fig. 3-27).

Remove any accumulation.

Reposition bottom plate (Fig. 3-22).

3-10

3-11

3-12

M

L

To re-assemble filter assembly, 

place

large knob of HEPA cartridge filter in
hole on bottom of pre-filter.

Snap top of HEPA cartridge filter into
place.

Align grooves (L) on pre-filter frame with
ribs (M) in dirt cup.

Slide filter assembly down into cup until
a light snap is felt.  Gently pull up on
assembly to ensure that it is seated
properly in the cup. Ensure that no part
of pre-filter screen extends above top
edge of dirt cup.

Close lid and return cup to cleaner (Fig.
3-5).

Note: 

If dirt cup lid does not close all

the way, first ensure that filter assembly
is pushed down all the way. Then, turn
knob on lid slightly until lid closes (see
Fig. 3-3).

3-13

N

O

Final filter

Replacing final filter

The 

final filter 

assists in the filtration

process to return clean air to the room.

To replace this filter when it becomes
dirty, open the door on the side of the
cleaner. Remove filter (N) and discard.

Reposition new filter on the side of
cleaner.  Make sure the white side of the
filter faces outward.  Close door.

Should you want to replace this filter,
ask for part 

No. 40110006.

Do not operate cleaner without the fil-
ter in place.

Removing lens

Disconnect cleaner from electrical
outlet.

Using a screwdriver, remove the two
screws as shown and lift off lens.

Installing bulb

Pull old bulb straight out of socket.  Push
new bulb straight into socket until locked
in place

Excessive force is not required.

Replacing lens

Reposition lens and secure with the two
screws. 

Continued

3-17

Содержание WindTunnel Self-Propelled U6616

Страница 1: ...This product was designed for easy Assembly See page 3 www hoover com Self Propelled WindTunnel Bagless with Powered Hand Tool by HOOVER...

Страница 2: ...ppliance before connecting or disconnecting hose Do not use without dirt cup or filters in place Empty cup and clean filter frequently when picking up very fine materials such as powder Use extra care...

Страница 3: ...d referral of authorized service outlet locations U S only OR Call 1 330 499 9499 to speak with a representative in our Consumer Response Center Continued Easy 3 step assembly Looking at the back of t...

Страница 4: ...ctric shock this appliance has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If...

Страница 5: ...rrying handle on the back of the cleaner 5 2 8 2 5 2 6 C D The green light will remain on through out cleaning except when the detector senses that a larger amount of dirt is being picked up then the...

Страница 6: ...nozzle for stair cleaning Clean from bottom to top CAUTION To avoid personal injury or unnecessary wear to carpet and to prevent the cleaner from falling always place it at bottom of stairs Cleaning t...

Страница 7: ...ued cleaning effectiveness Dirt cup The dirt cup assembly consists of the following parts Lid A Dirt Cup B Pre filter C HEPA Cartridge Filter D Dirt Inlet Opening E While the cleaner is in operation t...

Страница 8: ...idge filter and pull it away from pre filter Remove car tridge from assembly The pre filter can be cleaned with a brush and then rinsed with water Allow pre filter to dry thoroughly The HEPA cartridge...

Страница 9: ...ilter frame with ribs M in dirt cup Slide filter assembly down into cup until a light snap is felt Gently pull up on assembly to ensure that it is seated properly in the cup Ensure that no part of pre...

Страница 10: ...d What to buy When purchasing a new agitator ask for HOOVER part No 48414069 3 18 Belt replacement The belts are located under the bottom plate of the cleaner and should be checked from time to time t...

Страница 11: ...lt and posi tion belt in groove F on brush roll Replacing brush roll Removing brush roll Slide brush roll control Fig 2 9 to Hard OFF position Turn cleaner over and remove bottom plate Fig 3 18 Lift u...

Страница 12: ...broken replace it see follow ing section 5 Insert brush roll through belt and posi tion belt over gear teeth D on brush roll C D 3 31 3 32 E 6 With curved ends down slide end plates C of brush roll in...

Страница 13: ...nd cleaning may continue If the thermal protector continues to acti vate after following the above steps your cleaner may need servicing see Service section Service To obtain approved HOOVER service a...

Страница 14: ...n HEPA cartridge filter by either tapping the side of the dirt cup or removing the cartridge filter as described in the Filter assembly sec tion Pre filter clogged Clean pre filter as described in Fil...

Страница 15: ...the appliance to one of the following authorized warranty service outlets Proof of purchase will be required before service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty S...

Страница 16: ...16...

Отзывы: