background image

9

3-16

Agitator brush roll
replacement

When to replace

Disconnect cleaner from electrical
outlet.

When agitator brush roll brushes are
worn, the brush roll should be replaced.

To check condition of brushes, move
edge of a card across bottom plate while
turning brush roll.  To maintain cleaning
effectiveness, replace brush roll if brush-
es do not touch card.

What to buy

When purchasing a new agitator brush roll,
ask for HOOVER 

part no. 48414-071.

How to replace

Disconnect cleaner from electrical 
outlet.

1.  Remove hood, duct cover, belt and
brush roll as shown in Figs. 3-8 to 
3-13.

2.  Discard old brush roll.

3.  Replace new brush roll and belt as
shown in Figs. 3-13 to 3-15. 

Headlight replace-
ment

The headlight, located on top of the
power nozzle, operates when the clean-
er is turned on.  Use only HOOVER

part no. 27317-307

, which is a fused

bulb, when replacing the headlight. 

How to replace

Disconnect cleaner from electrical
outlet and disconnect power nozzle
from extension wands. 

1. Remove the hood as shown in Figs.
3-8 and 3-9.

3-17

2. Push old bulb into socket and twist to
remove.  Push new bulb into socket and
twist into place.
3. Replace hood.

2. Pull off both old edge groomers (K).

3.Push each new groomer onto the 3
tabs (L), starting with one of the end
tabs.  Then push the groomer onto the
middle and remaining end tab.

4. Replace brush roll cover and hood as
shown in Figs. 3-14 and 3-15.

3-18

Edge groomer
replacement

When to replace

The edge groomers, located on both
sides of the nozzle, should be replaced
when they no longer extend past the sur-
face of the bottom plate.

What to buy

When purchasing edge groomers, ask for
Hoover 

part no. 39511004.

How to replace

Disconnect cleaner from electrical
outlet.

1. Remove hood and brush roll cover as
shown in Figs. 3-8 to 3-10.

L

K

Lubrication 

The motor is equipped with two bear-
ings that contain sufficient lubrication for
the life of the motor.  The addition of
lubricant could cause damage.

Therefore, do not add lubricant to
either motor bearing.

The agitator brush roll is equipped with
two ball bearings  that should be lubri-
cated periodically by a Hoover Factory
Service Center or an authorized Hoover
Warranty Service Dealer (Depot). 

Thermal protector 

An internal thermal protector has been
used in your cleaner to prevent over-
heating if a large item or clog gets
caught in the nozzle or at the opening of
the bag.

When the blockage is not removed,
the thermal protector will trip and the
cleaner will stop running.

If this happens, turn cleaner OFF and

disconnect cleaner from electrical
outlet. 

Then disconnect nozzle and

remove obstruction. Within 15 minutes,
the thermal protector will cool and auto-
matically reset and cleaning may
resume.

If cleaner does not operate, allow addi-
tional time for thermal protector to reset.

Содержание WindTunnel S3755

Страница 1: ...Hoover WindTunnel Bagless Canister Cleaner with Powered Nozzle Owner s Manual English pp 1 11 Espa ol p g 12 17 Fran ais p 18 23 Review this manual before operating cleaner TM www hoover com...

Страница 2: ...bustible liquids such as gasoline or fine wood sandings or use in areas where they may be present The hose contains electrical wires Do not use if damaged cut or punctured Avoid picking up hard sharp...

Страница 3: ...in the Hoover Consumer Response Center Carton contents Connect hose wand and nozzle 1 2 1 3 A Connect hose Push the hose connector end A into the opening B on the front of the cleaner To disconnect h...

Страница 4: ...esired length 5 Hand grip 6 Upholstery nozzle dusting brush tool 7 Crevice tool 8 Large wheels provide easy towing when cleaner is pulled over carpet area rugs and door sills 9 Washable HEPA exhaust f...

Страница 5: ...z zle and pull handle back Turning cleaner on and adjusting power level After assembling cleaner plug cord into electrical outlet Turn cleaner on by pushing the Power ON Suction Control slide switch A...

Страница 6: ...or and carpeted stairs G Crevice tool may be used in tight spaces corners and along edges in such places as dresser drawers uphol stered furniture stairs and baseboards H Small brush is used for clean...

Страница 7: ...excess water from filter and allow to dry thor oughly before replacing it in cleaner Replace the filter by lining up tabs on fil ter with grooves on lid and rotating clockwise If the red light is sti...

Страница 8: ...ng on belt must be visible If belt is not broken but is stretched or cut pull it off the motor pulley H Stretch belt back and attach to motor pulley Hold opposite end of agitator brush roll in place P...

Страница 9: ...middle and remaining end tab 4 Replace brush roll cover and hood as shown in Figs 3 14 and 3 15 3 18 Edge groomer replacement When to replace The edge groomers located on both sides of the nozzle shou...

Страница 10: ...enses low suction or pickup the red Suction Control light will come on Low suction or pick up may be due to a blockage in the system Refer to the following steps to check for block ages continuing wit...

Страница 11: ...g the appliance to one of the following authorized warranty ser vice outlets Proof of purchase will be required before service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty...