Hoover Wet/Dry Vac Скачать руководство пользователя страница 6

6

Extension cord
instructions

Use an outdoor, grounding type,
SJT extension cord of 16 gauge (up
to 35 feet) or 14 gauge (any length).
The extension cord must employ a 
3-prong grounding type plug and a
3-pole receptacle that accepts the
machine plug.

Adapter

(Included with some models)

To use smaller diameter tools with
the 21/2-inch diameter hose, attach
the adapter (A) to hose.  Attach tool
to adapter.
Twist adapter and tool to tighten or
loosen connection.

Separate wet/dry
tanks

This feature allows you to change
from wet pick-up to dry pick-up
without having to empty the tank or
change filters.  Dry debris will
collect in the inner tank and wet
debris will collect in the outer tank.

Wear ear protection if operating
cleaner for a prolonged period 
of time.

Make sure that the small foam
and cartridge filters are in place. 

Dry pick-up

Disconnect cleaner from electrical
outlet.

With hose removed from cleaner,
slide wet/dry selector (A) to expose
“Dry tank inlet” (B).   Selector will
snap into place.  Insert hose into
“Dry tank inlet”.  
Attach the desired tool to hose end.

Make sure cleaner lid is locked in
place.  

Plug power cord into a 

properly

grounded outlet

and turn cleaner

ON.

Wet pick-up

Disconnect cleaner from electrical
outlet.

With hose removed from cleaner, slide
wet/dry selector (A) to expose “Wet
tank inlet” (C).  Selector will snap into
place.  Insert hose into “Wet tank
inlet”.  
Attach desired tool (with squeegee if
available) to hose end.

Make sure cleaner lid is locked in
place.  

Plug power cord into a 

properly

grounded outlet

and turn cleaner

ON.

Do not use cleaner as a pump to
clean out clogged drains, sinks, or
other plumbing fixtures.

If cleaner will not pick up, check
filters. They may need to be
cleaned or replaced (see
“Maintenance” section).

Single tank operation

For picking up very large amounts
of debris (either wet or dry), the
cleaner may also be operated
without the inner tank in place.

Disconnect cleaner from electrical
outlet.

Remove inner tank and set aside.

Attach hose to either the wet or dry
intake port.  Plug power cord into a

properly grounded outlet 

and turn

cleaner on.

When using single tank for dry
pick-up, cartridge filter must be 
in place.

For best results, when using
single tank for wet pick-up, use a
HOOVER® foam filter sleeve
instead of the cartridge filter.

See

“Filters” in the Maintenance section
for availability of HOOVER® filters.

Automatic wet 
shut-off

When either tank is full of liquid, the
automatic shut-off mechanism will
shut off cleaner pick-up.  When this
happens, the motor sound will
become noticeably higher in pitch.
Turn cleaner off and empty tank to
continue use.

The automatic shut-off will also
engage if the cleaner has been
tipped over.  To continue use, turn
cleaner off, and set it upright.  Wait
a few seconds to allow the motor to
come to a complete stop.

The automatic shut-off will
function for both separate wet/dry
tank and single tank operation. 

2-2

2-4

2-3

A

A

B

A

C

Содержание Wet/Dry Vac

Страница 1: ...Wet Dry Vac with Portable Blower and Exclusive two tank system Owner s Manual Read these instructions before operating cleaner...

Страница 2: ...not in use Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Never handle plug or appliance with wet hands If needed connect to a suitable...

Страница 3: ...e used to connect this plug to a 2 pole receptacle G if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet B can be installed by a q...

Страница 4: ...etters on cleaner tank Then align square tabs 1 on supports with rails 2 on tank Slide tabs onto rails until caster support 3 snaps in place Insert support screw into hole nearest tank Tighten screw w...

Страница 5: ...tank as shown Additional tools and accessories that are not included with your model are available at additional cost from your local Hoover Factory Service Center Authorized Hoover Warranty Dealer b...

Страница 6: ...o Wet tank inlet Attach desired tool with squeegee if available to hose end Make sure cleaner lid is locked in place Plug power cord into a properly grounded outlet and turn cleaner ON Do not use clea...

Страница 7: ...osition blower disconnect blower from electrical outlet Remove wand position blower on top of lid and secure latches CAUTION Wear safety goggles when using blower Do not blow toward people animals or...

Страница 8: ...ost instead of the cartridge filter Reusable cartridge filter Disconnect cleaner from electrical outlet After dry pick up remove filter D and gently tap it against inside of cleaner tank or brush off...

Страница 9: ...only OR checking the Service section of The Hoover Company online at www hoovercompany com Do not send your cleaner to The Hoover Company in North Canton for service this will only result in delay If...

Страница 10: ...demarks THE HOOVER COMPANY NORTH CANTON OHIO 44720 3 98 S6760 Litho USA 56514 020 HOOVER et sont des marques d pos es THE HOOVER COMPANY NORTH CANTON OHIO 44720 HOOVER y son marcas registradas THE HOO...

Отзывы: