Replace lid and filter on filter chamber.
Replace chamber on dirt cup.
3-8
Although not necessary, the filter can be
removed from the lid for cleaning.
Pull filter off lid and tap bottom of filter.
To replace, firmly press filter onto lid until
it stops.
Be certain that the dirt cup is locked in
the correct position.
3-12
3-13
How to replace
Disconnect cleaner from electrical
outlet.
With the handle in the upright position,
tilt cleaner back until it rests on floor.
Remove the 2 screws near the front of
the brush roll cavity.
Belt replacement
The belt on your Hoover cleaner causes
the agitator to rotate and is important for
the effective operation of the cleaner.
The belt is located under the hood of the
cleaner and should be checked from
time to time to be sure it is in good con-
dition.
When to replace
Disconnect cleaner from electrical
outlet.
To check belt, remove hood and agitator
cover as shown in Figs. 3-12 through 3-
14. Replace belt if it is stretched, cut or
broken.
What to buy
To assure effective operation, use only
genuine HOOVER belts with your
cleaner. When purchasing a new belt,
ask for
HOOVER part No. 40201190.
Press on handle release pedal (F) and
lower the nozzle so it is flat.
Remove hose end (Fig. 2-11).
Remove 2 screws at rear of hood.
3-10
Place bottom of cup behind tab (H) and
press cup into cleaner.
Rotate dirt cup handle (E) up to lock cup
in place.