background image

4

7

Press or slide cord into cord clip on back of handle.  Pull cord
tight (Fig. 7)

The assembled deep cleaner will look like the drawing below.

Carpet cleaning
machine description

1

2

3

3

4

5

6

7

8

9

10

11

12

13

14

14

15

16

1.

Hand grip

2.

Solution trigger:  

press to release clean solution.

3.

Cord hooks:  

wrap cord around hooks for storage.

The top hook can be rotated right or left for quick and easy
cord release.

4.

Carrying handle

5.

Clean solution tank handle

6.

Clean solution tank cap/ measuring cup

7.

Clean solution tank:  

holds cleaning solution.

8.

Recovery tank lid

9.

Recovery tank:  

holds dirty solution.

10. Recovery tank “front panel”
11. Hood
12. Nozzle
13. Upholstery and stair cleaning connection 

(some models

only)

:  

push door open to connect stair/upholstery tool

“solution tube”.

14. Recovery tank latches: 

one on each side of tank.

15. ON/OFF pedal
16.  Handle release pedal:  

step on pedal to lower handle

to operating position.

17.  Stair/upholstery nozzle

18

19

20

21

 

HOSE: 

 Stretch hose out and identify the following:

18.  Nozzle connector end of hose
19.  Trigger
20.  Converter end of hose
21.  Solution hose

17

This deep cleaner is intended for household use.

Содержание Deep Cleaner

Страница 1: ...c shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug A The plug must be plugged into an appropriate outlet B that is properly installed and grounded in accordance with all local codes and ordinances Grounding Instructions Thank you for selecting a HOOVER product This cleaner was inspected and packaged carefully before being shipped from the fact...

Страница 2: ...e or pets To assist in reducing drying time be certain the area is well ventilated when using detergents and other cleaners with this machine Keep detergents and other cleaners out of children s reach Do not use to pick up flammable or combustible liquids such as gaso line or use in areas where they may be present Do not pick up chlorine bleach drain cleaner gasoline or any other toxic material wi...

Страница 3: ... completely down 4 Place nuts in recessed areas on back of handle Hold each nut in place while tightening each bolt securely with a Phillips screw driver Fig 4 Only two nuts are needed on this model The extra nut is not required but has been provided for your convenience 5 SQUEEZE TRIGGER When handle sections are completely together squeeze trigger on upper handle to snap trigger rod in place Fig ...

Страница 4: ...ion tank cap measuring cup 7 Clean solution tank holds cleaning solution 8 Recovery tank lid 9 Recovery tank holds dirty solution 10 Recovery tank front panel 11 Hood 12 Nozzle 13 Upholstery and stair cleaning connection some models only push door open to connect stair upholstery tool solution tube 14 Recovery tank latches one on each side of tank 15 ON OFF pedal 16 Handle release pedal step on pe...

Страница 5: ...k before continuing use ON OFF pedal Handle release pedal Automatic shut off ON OFF PEDAL HANDLE RELEASE PEDAL FLOAT DISK How to fill TANK HANDLE Place handle in the upright locked position Carry tank to a sink Rotate tank cap counterclockwise and lift up to remove cap Continued To remove tank press down on handle and pull forward Clean solution tank upper tank General operation The deep cleaner m...

Страница 6: ... leaking remove clean solution tank by pressing down on tank handle and pulling forward set tank aside do not set tank on furniture Turn deep cleaner off and disconnect from electrical outlet Rotate recovery tank latches outward one on each side of tank Lift tank off of deep cleaner and carry it to a sink or drain Step on handle release pedal and lower handle until it rests on the floor If cleanin...

Страница 7: ...OOVER deep cleaner only if the upholstery fabric is marked with a W for wet clean or S W for solvent dry or wet clean Do not clean fabric marked S solvent dry clean only If your upholstery does not have a code seek professional assistance No cleaning solution removes all stains from all carpets Stain removal varies with the type of spill time elapsed before removal carpet material and carpet type ...

Страница 8: ...Upholstery Detergent Dry hands and plug cord into a properly grounded outlet When finished cleaning follow After cleaning instructions on page 8 For best cleaning results and to aid in faster drying of carpet end with more dry strokes Continue using dry strokes until little water is visible passing through the recovery tank lid It is best to alternate wet and dry strokes as described above Keep no...

Страница 9: ...hment downward until both ends snap into place Note Some force may be required to rotate and snap attachment into place Return deep cleaner to upright position To clean floor Read Before you begin cleaning instructions on page 7 Do not use deep cleaner on hardwood floors Fill clean solution tank according to instructions on pages 5 6 Use 5 ounces of HOOVER Bare Floor Cleaner Do not use any type of...

Страница 10: ...tank Rotate lid down onto tank Make sure lid is secure on all sides before cleaning For full suction it is important that the recovery tank lid is properly secured before cleaning Reverse procedure to remove hose and solution tube Raise deep cleaner handle to upright position and replace upper clean solution tank Attach nozzle to connector end of hose by sliding it onto connec tor until the tab lo...

Страница 11: ...against riser Pull nozzle slowly over carpet without pressing trigger dry stroke Position nozzle against the riser and slightly press nozzle into carpet pile Press the solution trigger and pull the nozzle slowly over the carpet second wet stroke Replace recovery tank front panel Slide panel down until it snaps firmly in place Snap clip back into position making sure solution hose is not pinched an...

Страница 12: ...n place If you have a problem Problem Machine won t run If a minor problem occurs it usually can be solved quite easily when the cause is found by using the check list below Possible cause Possible solution Not firmly plugged in Plug unit in firmly No voltage in wall plug Check fuse or breaker Blown fuse tripped breaker Replace fuse reset breaker Problem Low suction Possible cause Possible solutio...

Отзывы: