![Honeywell ZW3005 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/honeywell/zw3005/zw3005_manual_150403003.webp)
39351/ZW3010
Parameter and Command Class List
Parameter
number
Parameter:
Length
Valid value
Description
3
LED indication
configuration
1
O(default),1,2,3
0
= The device is
ON,
LED is
OFF;
the device is
OFF,
LED is
ON
1 = The device is
ON,
LED is
ON;
the device is
OFF,
LED is
OFF
2 = LED always
OFF
6
Dim up/down rate
1
O(default),l
3 = LED always
ON
0 = Dim up/down the light to the specified level
quickly by command except value O and
FF
1 = Dim up/down the light to the specified level
slowly by command except value
O
and
FF
16
Enable/Disable Switch
1
O(default),l
0
= Disable
mode
1 = Enable
19
Alternate exclusion
1
O(default),l
0
= Press any button on the switch
1 = Press two times
ON
button and two times
OFF
button, LED will flash 5 times if exclusion succeed
30
Minimum Dim
1
l(default)-99
Set the minimum dimmer threshold when manually
Threshold
or remotely controlled
1=1%
99 = 99%
31
Maximum Brightness
1
99 (default )
-
1
Set the maximum brightness threshold when
Threshold
manually remotely controlled
99= 99%
1= 1%
32
Default Brightness
1
O(default), 1-
Set the default brightness level that the dimmer will
Level
99
turn on when being turned on manually
1=1%
99 = 99%