Overview
2. Overview
3. Installation
The room unit HCW 80 is used for intelligent room
temperature control in combination with the relay module
HC60NG. It can be used to control gas and oil boilers, a
variety of valves and actuators or electrical heating systems.
No wiring to the room unit HCW 80 is required.
3.1.
Installation relay module HC60NG
Because of the simple HCW 80 analogue user interface with
absolute set point temperature scale, the room set point
temperature can be easily adjusted.
The room unit and the relay module provide reliable RF
communication technology on 868 MHz frequency.
The HCW 80 and HC60NG are already teached-
in (bounded). They are provided as pre
configured kit for fast installation (plug and play).
Fig. 2: Positioning the relay module HC60NG
►
Follow the installation diagrams to install and connect the
power supply to the relay module HC60NG.
Wireless Room Thermostat
HCW80
Boiler
Relay module
HC60NG
Example radiator control
Zone 1
1
1
2
Fig. 1: Application of the wireless room thermostat
2.1.
Pre configured kit Y6630D1007
Fig. 3: Opening the housing cover
•
1 HCW 80 (room unit)
•
1 HC60NG (R6660D1009, relay module)
•
2 AA batteries, 1.5 V, type LR6
1
2
The kit Y6630D1007 is provided pre-bound.
The room unit HCW 80 is already assigned to the
relay module HC60NG. The teach-in is not
required in this kit.
2.2.
Singly provided devices
Singly provided devices must be teached-in as
described in section 5 “Teach-in (singly provided
devices only)”.
Teach-in means the HCW 80 and HC60NG must
be RF bound for communication.
Fig. 4: Removing the terminal covers
> 7 mm
Æ
< 7 mm
Æ
Fig. 5: Connecting the relay module to the power supply
6