Quiet Operations

The following codes configure the scanner and base to quiet modes 
for scanning that does not disturb resting patients. 

Silent Mode with Flashing LED

Scan the following bar code to completely silence the base and 
scanner.  When a bar code is scanned, the LED and aimer flash 5 
times.  Green indicates a good scan, red indicates a bad scan.

Silent Mode with Flashing LED

Silent Mode with Long LED

Scan the following bar code to completely silence the base and 
scanner.  When a bar code is scanned, the LED and aimer remain 
solidly lit for 1 second.  Green indicates a good scan, red indicates a 
bad scan.

Silent Mode with Long LED

Содержание Xenon 1902HC

Страница 1: ...laidc com für Deutsch Ir a www honeywellaidc com para español Para Português acesse www honeywellaidc com br Перейти на русскоязычный сайт www honeywellaidc com Pro češtinu jdi na www honeywellaidc com Pre slovenčinu choď na www honeywellaidc com 日本語 www honeywellaidc com をご覧ください 如要到中国 www honeywellaidc com 简体 查看繁体版请登陆 www honeywellaidc com 한글 www honeywellaidc com 로 이동합니다 http manualforhoneywellt...

Страница 2: ...power before connecting the base then power up the computer once the base is fully connected When the base is connected and powered up put the scanner in the base to establish a link The green LED on the base flashes to indicate the scanner s battery is charging Power Supply Assembly if included Note The power supply must be ordered separately if needed http manualforhoneywellthermostat com ...

Страница 3: ...Connecting the Scanner USB Keyboard Wedge http manualforhoneywellthermostat com ...

Страница 4: ...r code pull the trigger and center the aiming beam on the bar code The aiming beam is smaller when the scanner is closer to the code and larger when it is farther from the code Hold the scanner close to smaller bar codes and farther away from large bar codes to get a proper read If the bar code is highly reflective e g laminated you may need to tilt the scanner at an angle so the bar code can be s...

Страница 5: ...am the scanner to emulate a regular RS232 based COM Port If you are using a Microsoft Windows PC you will need to download a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver USB Serial Note No extra configuration e g baud rate ...

Страница 6: ... into the base or scan the linking bar code on the base or Access Point to relink your scanner Meditech Scan the following bar code to configure your device to communicate with a Meditech software application Meditech Application After scanning this code you must put the scanner into the base or scan the linking bar code on the base or Access Point to relink your scanner ...

Страница 7: ... the base and scanner When a bar code is scanned the LED and aimer flash 5 times Green indicates a good scan red indicates a bad scan Silent Mode with Flashing LED Silent Mode with Long LED Scan the following bar code to completely silence the base and scanner When a bar code is scanned the LED and aimer remain solidly lit for 1 second Green indicates a good scan red indicates a bad scan Silent Mo...

Страница 8: ...ep base and scanner power up beep and scanner linking sounds are all silenced When a bar code is scanned the scanner emits a very soft beep Nighttime Mode Low Beeper Daytime Mode Scan the following bar code to set all sounds to on but at a low volume The scanner beep base beep base and scanner power up beep and scanner linking sounds are all set to low volume Daytime Mode ...

Страница 9: ...is out of the base press the page button once to make the scanner beep so you can locate it Press the scanner s trigger to stop the page beeping When the scanner is in the base press the page button once and the scanner shines the aimer until a bar code is presented to it If the scanner doesn t see a bar code in 10 seconds the aimer shuts off ...

Страница 10: ...move Suffix bar code to remove the suffixes Add CR Suffix Remove Suffix Add Tab Suffix Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once Add Code ID Prefix To All Symbologies Temporary Note For a complete list of Code IDs see the User s Guide for your product at our website www honeywellaidc com ...

Страница 11: ...ide Locked Scanner If you need to replace a broken or lost scanner that is linked to a base scan the Override Locked Scanner bar code with a new scanner and place that scanner in the base The locked link will be overridden the broken or lost scanner s link with the base will be removed and the new scanner will be linked Override Locked Scanner Unlinking the Scanner If the base has a scanner linked...

Страница 12: ...w to program the keyboard layout for your country or language As a general rule the following characters are supported but need special care for countries other than the United States USA Default Belgium Denmark Finland France Germany Austria Great Britain ...

Страница 13: ...Note For a complete list of country codes see the User s Guide for your product at our website www honeywellaidc com Italy Norway Spain Switzerland ...

Страница 14: ...t and to download the User s Guide go to www honeywellaidc com Disclaimer Honeywell International Inc HII reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult HII to determine whether any such changes have been made The information in this publication does not represent a commitment on ...

Страница 15: ...ected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2014 Honeywell International Inc All rights reserved Web Address www honeywellaidc com ...

Страница 16: ......

Отзывы: