W8665A,E RF RECEIVER MODULE
3
69-1630-1
Fig. 2. Connecting the W8665A RF Receiver Module to the equipment.
Fig. 3. Connecting the W8665E RF Receiver Module to the equipment in a one-zone application.
M20163C
COMM
T8665A
THERMOSTAT
ZONE 1
W8665A
LED
LED
LED STATES:
COMM:
RAPIDLY FLASHING GREEN – RECEIVING INFORMATION FROM THERMOSTAT.
GREEN OFF – STANDBY, READY TO RECEIVE INFORMATION.
ZONE:
RED ON – SYSTEM (HEAT, COOL OR FAN) IS ON.
RED OFF – SYSTEM (HEAT, COOL OR FAN) IS OFF.
FLASHING RED – ERROR. NOT RECEIVING SIGNAL FROM THERMOSTAT.
RAPIDLY FLASHING RED – RECEIVER IN SET-UP MODE.
DIP SWITCH SETTINGS:
OFF: NOT SET-UP TO RECEIVE INFORMATION FROM A THERMOSTAT.
ON: READY TO RECEIVE INFORMATION FROM THERMOSTAT AFTER
SET-UP IS COMPLETE.
SET-UP:
MOVE DIP SWITCH TO ON POSITION AND MAKE THERMOSTAT CALL FOR FAN.
NOTE: ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET-UP.
ZONE 1
ZONE 2
ZONE 3
ON
HEAT
RELAY
COOL
RELAY
FAN
RELAY
L2
L1 (HOT)
Y W G
ZONE 1
R C RZ
FACTORY INSTALLED JUMPER.
1
1
M19753
COMM
T8665A
THERMOSTAT
ZONE 1
W8665E
LED
LED
ZONE 2
LED
ZONE 3
LED
LED STATES:
COMM:
RAPIDLY FLASHING GREEN – RECEIVING INFORMATION FROM THERMOSTAT.
GREEN OFF – STANDBY, READY TO RECEIVE INFORMATION.
ZONE:
RED ON – SYSTEM (HEAT, COOL OR FAN) IS ON.
RED OFF – SYSTEM (HEAT, COOL OR FAN) IS OFF.
FLASHING RED – ERROR. NOT RECEIVING SIGNAL FROM THERMOSTAT.
RAPIDLY FLASHING RED – RECEIVER IN SET-UP MODE.
DIP SWITCH SETTINGS:
OFF: NOT SET-UP TO RECEIVE INFORMATION FROM A THERMOSTAT.
ON: READY TO RECEIVE INFORMATION FROM THERMOSTAT AFTER
SET-UP IS COMPLETE.
SET-UP:
MOVE DIP SWITCH TO ON POSITION AND MAKE THERMOSTAT CALL FOR FAN.
NOTE: ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET-UP.
ZONE 1
ZONE 2
ZONE 3
ON
HEAT
RELAY
COOL
RELAY
FAN
RELAY
L2
L1 (HOT)
Y W G
ZONE 1
Y W G
ZONE 2
Y W G
ZONE 3
R C RZ RZ RZ
FACTORY INSTALLED JUMPER.
1
1