6 - 3
External Output
External Illumination Control
The External Illumination Control allows the third party device to use external illumination, supplemental to the illumination
from the scanner. If the illumination will be provided by the third party device, scan the
External Illumination Control On
bar code.
Default = External Illumination Control Off
.
External Illumination Parameters
Absolute Maximum
Maximum voltage on output pin with scanner powered
down.
High Value: 6 Volts
This allows a pull-up to be connected to this line provided it
does not exceed the current on the next line of this table
while operating.
Maximum current driven into pin from external source.
High Value: 5mA
Maximum current limited by series resistor dissipation.
Parameter Values
Output Low Voltage
Iout = 500uA
High Value: 0.6 Volts
Internal one-hundred ohm series resistor drop included.
Output Low Voltage
Iout = 1mA
High Value: 0.7 Volts
Output Low Voltage
Iout = 4mA
High Value: 1.0 Volts
Output Low Voltage
Iout = 6mA
High Value: 1.2 Volts
Output High Voltage
Iout = -500uA
Low Value: 3.6 Volts
Output High Voltage
Iout = -1mA
Low Value: 3.5 Volts
Output High Voltage
Iout = -4mA
Low Value: 3.3 Volts
Output High Voltage
Iout = -6mA
Low Value: 3.1 Volts
* External Illumination Control Off
External Illumination Control On
Содержание Vuquest 3330g
Страница 1: ...Vuquest 3330g Area Imaging Scanner User s Guide ...
Страница 10: ...viii ...
Страница 12: ...x ...
Страница 40: ...2 24 ...
Страница 62: ...3 22 ...
Страница 80: ...5 14 ...
Страница 134: ...7 50 ...
Страница 150: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Страница 152: ...9 4 ...
Страница 199: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...
Страница 201: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 3330 UG Rev A 10 15 ...