8. Temperature Scale

The VT15 is adjusted by turning the top anticlockwise to increase the 

temperature setting or clockwise to decrease the temperature setting.

These temperatures are for guidance only and may vary slightly depen-

ding on the nature of the installation.

9. Using the “Memory Clip“

1. Remove “Memory Clip” and fit 

into required setting Position

10. Temperature limiting

To set the upper limit: 

1. Set to the required value and insert the right 

hand stop bar with the “Memory Clip”

To set the lower limit: 

1. Set to the required value and insert the left 

hand stop bar with the “Memory Clip”

11. Temperature locking

1. Set to the required value and insert the 

right and left hand stop bars with the 

“Memory Clip”

12. Removal of temperature 

limits and locking

1. Remove stop bars with the 

“Memory Clip“

13. Fitting Valve Connections

Copper Connections

1. Cut copper tube to an entry depth 

of 8mm

Radiator Connections

1. Screw 1/2’’ BSP tailpiece into the 

tapping on radiator.

14. Specification

15. Servicing

Use the service tool VA8200A001 for 

cleaning or replacement of the valve 

seating without draining the system.

For further informations see seperate 

manual.

16. Radiator Removal

If it is necessary to remove the radiator for decorating or other reasons, 

ensure that the thermostatic head is positioned at the `0´ position.

However, if the temperature in the room falls below 6°C, the thermostat 

will open.

If there is any possibility that the temperature in the room will fall below 

6°C, then the decorators cap supplied with the valve should be used to 

isolate the flow.

17. Check list

• Check all connections for securing and leaks.

• Use clean pipework, free from swarf.

• Consider the use of an automatic by-pass valve 

(e.g. Honeywell DU145) to ensure the specification is adherded to.

• Don’t allow heat from blow torch onto body.

• Don’t install the valve in a position which is subject to draughts, sun 

radiation or behind curtains.

• Don’t overtighten the head/body connection, as the insulating sleeve 

may become damaged.

NOTE:

Ensure that the foam insert located in the thermostatic head 

is in place in the head before the head is attached to the 

valve body.

6°C

10°C

15°C

20°C

23°C

26°C

0

*

1

2

3

4

5

Thermo-

static off

Frost 

Position

Normal

Setting

3

5

3

5

3

5

3

5

3

5

3

5

8mm

8mm

OR

Maximum flow temperature

130°C (266°F)

Maximum working pressure

10 Bar (150psi)

To ensure that the valve will thermostatically close the differential pres-

sure must not exceed 1.0 bar.
Maximum differential pressure to ensure reliable and quiet operation is 

0.2 bar.
Hystersis

<1.0k

Heat conduction

0.6k

Change in differential pressure

0.4k

Closing time

20 mins

CEN Approved 

EN215