Honeywell VC7900 Series Скачать руководство пользователя страница 1

VC7900 Series 

Modulating Control Valves 

GENERAL 

The VC7900 Series Modulating Control Valves provide 
precision flow  control of hot or chilled water in various heating 
and cooling applications. 

The VC hydronic valve consists of a valve body and 
replaceable characterized cartridge assembly.  When used 
with a Honeywell VC7900 actuator, the valve provides 
proportional flow in modulating, diverting or mixing 
applications.  They are designed to operate silently and resist 
water hammer.  These actuators have conformally coated 
printed circuit boards for humidity resistance. 

VC7934 actuators meet the requirements of UL94-5V fire 
retardancy for mounting in return air plenums. 

The VC7900 series valve actuator is used with any 
0–10 Vdc or 2–10 Vdc  controller. 

PRODUCT DATA 

FEATURES 

•  

All actuators are interchangeable and suitable for all  valves, 
1/2" through 1", providing maximum installation flexibility 
with minimum stock. 

•  

Replaceable cartridge provides easy valve serviceability 
without plumbing. 

•  

High close-off pressure rating is suitable for open systems 
and hydronic HVAC systems with temporary high head 
pressure. 

•  

Actuator is constructed of moisture and humidity resistant 
materials. 

•  

Motor de-energiszes when valve not in motion, extending 
service life. 

•  

Manual opener and position indicator.  This "manual opener" 
may be used for filling, venting, and draining the system. 

•  

Twist-lock actuator can be installed after plumbing work has 
been completed, which makes for more efficient on-site 
installation.  Multi-directional actuator mount allows for 4 
different wiring orientations, thus providing ease of wiring 
and service. 

•  

Body dimensions are comparable to existing Honeywell 
products (V4043/4044 and V8043/8044), and in most cases 
can be interchanged. 

•  

Sweat-fitted valves are supplied with the cartridge loose, to 
facilitate soldering operations (an installation tool is in­
cluded). 

•  

In this balanced valve design, the internal piston moves up 
and down across the water flow.  The actuator provides 
sinusoidal piston travel action for "soft shut-off" and open, to 
eliminate water hammer in most applications. 

•  

In 2-way valves, flow can be in either direction. 

•  

In 3-way valves, flow can be mixing or diverting. 

CONTENTS 

Specifications ..........................................................  2 
Ordering Information ...............................................  2 

Installation ................................................................... 4 

Wiring ......................................................................  5 
Operation ................................................................ 5 
Service .................................................................... 6 
Check-out ................................................................ 6 

KT/RJ 

• 

12/97 

 © Honeywell Limited 1997 

• 

Form Number 95C-10830-2 

Содержание VC7900 Series

Страница 1: ...tems with temporary high head pressure Actuator is constructed of moisture and humidity resistant materials Motor de energiszes when valve not in motion extending service life Manualopenerandpositionindicator This manualopener may be used for filling venting and draining the system Twist lock actuator can be installed after plumbing work has been completed which makes for more efficient on site in...

Страница 2: ... actual 2 to 9 Vdc Input impedance 47 5 kΩ Power Consumption 4 Watts Max at nominal voltage during valve position change Note Use 24 V Class 2 transformer Provide 6 VA for connec tion wire sizing Maximum duty cycle 15 Nominal Timing Opens in 2 minutes 60Hz Actual full stroke timing is 140 sec Note Timing is approximately 20 longer 50Hz Electrical Termination 3 Versions Available 1 Molex header 39 ...

Страница 3: ... BSPP ext 94 3 11 16 113 4 7 16 22mm Compression 112 4 7 16 113 4 7 16 1 SWEAT 94 3 11 16 113 4 7 16 1 F NPT 94 3 11 16 113 4 7 16 1 BSPP int ext 94 3 11 16 113 4 7 16 28mm Compression 116 4 9 16 113 4 7 16 C E Dimensions Pipe fitting sizes mm Inches mm Inches 3 8 FLARE no adapter 98 3 7 8 136 5 11 32 1 2 SWEAT 98 3 7 8 136 5 11 32 1 2 F NPT 98 3 7 8 136 5 11 32 1 2 FLARE no adapter 98 3 7 8 136 5...

Страница 4: ... operation of this product good installation practice includes initial system flushing and the installation of 50 micron or finer system side stream filter s Fig 4 Plumbing the VC Valve COMPRESSION MODELS For compression fitted models tighten the compression nuts enough to make a watertight seal TAKE CARE NOT TO OVER TIGHTEN Maximum torque limit is 45 Nm 33 ft lb for the 22 mm compression fitting ...

Страница 5: ...lves may be connected in parallel to a single controller and transformer up to the current rating of the controller and transformer Fig 6a Connector Pin Configuration for Molex Model and 0 2 10 Vdc Controllers Series 70 0 10 Vdc 1 6 5 4 3 2 L1 HOT L2 Fig 6b Wiring Colour Code for Cable Models and 0 2 10 Vdc Controllers Series 70 Brown Black Blue L1 HOT L2 0 10 Vdc CONDUIT CONNECTION VC7934 may be ...

Страница 6: ...sted for silent operation in properly designed and installed systems However water noises may occur as a result of excessive water velocity Piping noises may also occur in high temperature over 212 F 100 C systems with insufficient water pressure IMPORTANT Do not use boiler additives which are petroleum based or contain mineral oil hydrocarbons or ethylene glycol acetate Compounds which can be use...

Отзывы: