27 

27 

User-selectable (°F or °C) temperature display 

Remote channels auto-scan feature   

Maximum number of remote sensors: 3 (one included) 

Readings update interval: every 45 seconds 

Low battery indicators – for each remote channel and main unit 

EL

 backlight 

Clock 

Precise atomic time 

4 US Time Zones 

12/24 hour time format 

Crescendo 4 minutes alarm with 5 minutes snooze 

Remote Sensor

 

Temperature  

Proposed operating range with alkaline batteries: 

-4°F to + 158°F (-20°C to + 70°C) 

Proposed operating range with lithium batteries:   

-38.8°F to +158°F (-38.8°C to + 70°C) 

Temperature resolution: 0.1°C/0.2°F 

Humidity  

Operating Range: 30% to 80% 

Resolution: 1% 

Low battery indicator 

Wall-mount of Table stand 

Power 

Main unit: 2 x UM-3 or AA 1.5V battery 

Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery 

Battery life (alkaline) 

Main unit: 2 month   

Thermo-Hygrometer: over 12 months 

Dimensions 

Main unit: 7.31 (L) x 3.68 (H) x 1.31 (D) inches     

Remote Thermo - Hygrometer: 2.37(L) x 4(H) x 1(D) inch   

 

 

 
 
 
 

28 

FCC STATEMENT 

This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, 
and (2) This device must accept any interference received, including 
interference that may cause undesired operation.   
Warning: Changes or modification to this unit not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the 
equipment. 
NOTE: This equipment had been tested and found to comply with the limits for 
a Class B Digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment, installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. 
There is no guarantee that interference will not occur in a particular installation. 
If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the 
user is encouraged to improve or correct turning the interference by one or 
more of the following measures: 

 

Reorient or relocate the receiving antenna 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment to an outlet on a circuit different from that to 
which the receiver is connected. 

 

Consult the dealer or an experienced radio / TV technician for help. 

 
 
 
 

Содержание TS33C

Страница 1: ...SURE MODE 15 REMOTE AND INDOOR TEMPERATURE HUMIDITY 16 AUTO SCANNING 17 PROGRAMMABLE TEMPERATURE ALARM 17 COMFORT LEVEL INDICATORS 18 MAXIMUM AND MINIMUM READINGS 19 LOST COMMUNICATION 19 TRANSMISSION COLLISION 20 WWVB RADIO CONTROLLED TIME 20 ATOMIC CLOCK 21 TIME AND CALENDAR DISPLAY MODES 22 MANUAL SETTINGS 22 CLOCK ALARMS 23 SNOOZE 24 BACKLIGHT 25 TROUBLESHOOTING 25 PRECAUTIONS 26 SPECIFICATION...

Страница 2: ...nstall batteries in the remote sensor before the main unit Insert batteries before first use matching the polarity in the battery compartment Remove protective plastic screen from LCD display if any During an initial setup place the remote sensor close to the main unit After reception is established all remote readings will appear on the main unit s display position the remote sensor and the main ...

Страница 3: ...s the temperature display in Fahrenheit or Celsius NOTE Install the batteries select the channel and temperature in C or F before mounting the sensor BATTERY INSTALLATION Remove the screws from the battery compartment with a small Phillips screwdriver Set the channel 1 through 3 The switch is located in the battery compartment Channel 1 is typically selected if only one remote sensor is being used...

Страница 4: ...d all remote sensors It should be placed indoors FEATURES Time Time automatically sets to the US Atomic Clock 12 or 24 hour time format Manual adjustment of time and date Day of the week displayed in English Spanish French German and Italian Moon Phase calendar Dual crescendo alarms with programmable snooze Programmable Ice Warning Alarm 8 Weather Weather forecast for the next 12 to 24 hour in fiv...

Страница 5: ... into the alarm programming mode for a selected parameter E TEMP ALARM button Allows toggling between high low limits for temperature alarm and current outdoor temperature reading Activates a high low temperature alarm programming mode F UP button Increases the parameters When depressed and held activates manual search for atomic time signal Enables or disables time alarms W and S and Ice Warning ...

Страница 6: ...move the table stand from the unit PLACEMENT Make sure that the main unit is locating within the operating range of the remote sensor Ideally the remote sensor should be mounted within the line of sight of the main unit Transmission range may be affected by trees metal structures and electronic appliances Test reception before permanently mounting the remote sensor Avoid placing the main unit in t...

Страница 7: ...cal altitude units and value To set the pressure altitude units and program your altitude use the main unit buttons located on the back Press UP or DOWN button on the back of the unit selecting the pressure in inHg or hPa mBar Press UNIT button to confirm and move to the altitude unit selection mode Press UP or DOWN button selecting the altitude unit in feet or meters Press UNIT button to confirm ...

Страница 8: ...either button for the quick digits advance Press PRESSURE ALTITUDE button to confirm selection REMOTE AND INDOOR TEMPERATURE HUMIDITY After batteries are installed remote sensor will transmit temperature and humidity data at 45 second intervals The main unit may take up to two minutes to receive the initial readings Upon successful reception remote temperature and humidity will appear next to the ...

Страница 9: ...ls Press the TEMP ALARM button once to enter into the High Temperature Alarm programming mode the abbreviation OF with the high temperature limit symbol will be displayed on the remote temperature line Press and hold TEMP ALARM button until the abbreviation OF will 18 flash Use UP or DOWN T arrow buttons to adjust the higher temperature limit Press the TEMP ALARM button to confirm the selected val...

Страница 10: ...e sensor with small Phillips screwdriver and open the battery compartment Remove the batteries from the battery compartment and reinstall them in the same manner Remote sensor LED indicator will flash showing transmission of the signal Remove the batteries from the main unit and reinstall them in the same manner On the main unit select the same channel number using CHANNEL button as set on the rem...

Страница 11: ...Time Zone having in mind that the default zone is a US Pacific Standard Time PST Refer to MANUAL SETTINGS section If the time signal has not been received in 8 minutes you may use the MODE button to set the time and date manually Refer to the MANUAL SETTINGS section 22 After the clock is set manually place the Weather Forecaster by the window for the better reception The atomic clock receiver is p...

Страница 12: ...een set previously Press and hold ALARM button for two seconds The hour digit will flash Adjust the hour using UP or DOWN buttons 24 Press ALARM button again The minute digits will flash Adjust the minutes using UP or DOWN buttons Press ALARM button again to confirm and the weekday alarm time will be set Set Single S day alarm if desired in the same manner SETTING THE ICE WARNING ALARM PRE AL If W...

Страница 13: ...ch Press and hold DOWN button on the main unit 26 PRECAUTIONS This product is engineered to give you years of satisfactory service if handled carefully Here are a few precautions Do not immerse the units in water Do not clean the units with abrasive or corrosive materials They may scratch the plastic parts and corrode the electronic circuits Do not subject the product to excessive force shock dust...

Страница 14: ...e harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modification to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment had been tested and found to comply with the limits for a Class B Digital devi...

Страница 15: ... abuse commercial use or unauthorized adjustment and repair Note that online product registration is required to ensure valid warranty protection To register your product go to our Company website at www honeywellweatherstations com Click Online Product Registration under the Customer Service menu Should you require assistance with this product and its operation please contact our Customer Service...

Отзывы: