Honeywell TRADELINE T8400C Скачать руководство пользователя страница 7

69-1493–1

7

T8400C  ELECTRONIC THERMOSTAT

Cooling

CAUTION

Low Temperature Hazard.
Operating at too low of an outdoor temperature
may cause compressor damage.
Do not operate cooling if outdoor temperature is
below 50

°

F (10

°

C). Refer to equipment manufac-

turer instructions.
• For compressor protection, during power

interruption and on initial startup, the T8400C
Electronic Thermostat will go into a five minute
delay. During this delay, the cooling icon, a
snowflake        , will flash.

1. Slide the SYSTEM switch to Cool and the FAN

switch to Auto.

2. Press the 

▼ 

key to lower the temperature setting

several degrees below the room temperature. After
approximately five minutes, the cooling equipment
should start. The fan starts and stops with the
cooling equipment.

3. Press the 

▲ 

key to raise the temperature setting

above the room temperature. Cooling system should
shut down.

NOTE:

To bypass the five minute delay, see Optional
System Checkout section.

Fan

1. Slide the SYSTEM switch to Off and the FAN switch

to On. The fan should run continuously.

2. Slide the FAN switch to Auto. In heating, the fan is

controlled directly by the heating equipment and
may start a few minutes after the heating equipment
turns on (on most systems). When using an electric
heat thermostat, the fan starts and stops with the
heating equipment. In cooling, the fan starts and
stops with the cooling equipment.

Make certain all equipment responds properly to the
thermostat.

Содержание TRADELINE T8400C

Страница 1: ...ctronicThermostat INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check o...

Страница 2: ...ions normally even when not level Mount wallplate with the screws provided see Fig 2 as follows 1 Place the wallplate at the desired location on the wall 2 Pull the thermostat wire through the wallplate entrance hole 3 Select the two mounting holes that best fit the application 4 Fasten the wallplate to the wall using the anchors and screws provided 5 After wiring the wallplate plug the hole to pr...

Страница 3: ...g the T8400C Thermostat All wiring must comply with local electrical codes and ordinances Disconnect the power supply to prevent electrical shock or equipment damage NOTE To ensure proper mounting of thermostat restrict all wiring to the shaded area See Fig 4 The shape of the terminals permits insertion of straight or wraparound wiring connections either method is accept able See Fig 5 Fig 4 Restr...

Страница 4: ...TION AS REQUIRED REMOVE RC TO R JUMPER WHEN INSTALLED ON A TWO TRANSFORMER SYSTEM CAN BE USED FOR CHANGEOVER VALVE ON SINGLE STAGE HEAT PUMP SYSTEMS POWER TO R TERMINAL IS REQUIRED WHEN THE SYSTEM SWITCH IS IN THE OFF POSITION 2 3 3 1 1 3 4 Fig 9 Mounting thermostat to wallplate L1 HOT L2 1 COOL CHANGEOVER FAN RELAY COOL RELAY HEAT RELAY 24V M13277A HEAT CHANGEOVER TRANSFORMER 1 POWER SUPPLY PROVI...

Страница 5: ... setpoint and the room temperature are shown separately on the digital display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed To set temperature setpoint 1 Select Heat or Cool by sliding the SYSTEM switch in the lower right corner of the thermostat to the desired mode See Fig 10 2 To display the temperature setpoints on the...

Страница 6: ...indication 6 Press the key to display the heat cycle rate of 1 3 4 5 6 9 or 12 If the desired cycle is displayed press the key to exit the installer setup mode To change the heat cycle rate press the key to scroll between 1 3 4 5 6 9 and 12 Stop scrolling when the desired rate is displayed See Table 1 for the cycle rate options and the corresponding system equipment a High Efficiency Furnace b Ref...

Страница 7: ...m temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cooling equipment 3 Press the key to raise the temperature setting above the room temperature Cooling system should shut down NOTE To bypass the five minute delay see Optional System Checkout section Fan 1 Slide the SYSTEM switch to Off and the FAN switch to On The fan should run con...

Страница 8: ... Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome ...

Отзывы: