10
HUMIDITY CONTROL SETTING
When the unit is switched ON, the Display Screen shows the current humidity percentage.
Press or to select your preferred humidity level. The humidity is adjusted in increments of 5%
by pressing or . The adjustable Relative Humidity (RH) range is between 30% RH to
90% RH. Ten seconds after setting the preferred humidity setting, the display will revert back
to displaying the current humidity.
IMPORTANT
: There is a 5% threshold when the desired humidity setting has been reached. The
compressor will shut off once the relative humidity is 5% lower than your desired setting. The fan will
continue to run for up to 3 minutes to cool the motor and will then shut off. Operation restores once
the relative humidity is 5% higher than your desired setting.
Recommended Settings:
It is recommended to leave the unit running at 30% humidity at
High Fan Speed during the first 2 to 3 days until damp odors are removed. After a few days when
the Relative Humidity has been reduced to a more comfortable level, press or to choose a
higher RH% that maintains a comfortable humidity level thereafter. A recommended healthy
humidity level is between 40% and 50%.
NOTE:
The humidity sensor senses current humidity in the surrounding area. It is normal for about
a 5% variance above or below the actual relative humidity in the room. Therefore, if there is a slight
variance, the unit may sometimes operate slightly longer or shorter than the set RH% level.
CONTINUOUS MODE
To activate the Continuous Mode, press the
button on the Display Screen until appears.
The indicator light will be illuminated. The unit will run continuously.
FUNCTION BUTTONS
USE & OPERATION (CONTINUED)
EN
POWER CONTROL
Press
to switch the dehumidifier ON or OFF.
CO