Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide
227
•
Open the status bar icon in the lower right hand corner of the status bar. Then tap the
Disconnect button.
When the Thor VM3 loses connection, e.g.: enters Suspend Mode, etc., the connection to
ActiveSync will be lost.
Reset and Loss of Host Re-connection
ActiveSync assigns a partnership between a Thor VM3 (the client) and a host computer.
A partnership is defined by two objects – a unique computer name and a random num-
ber generated when the partnership is first created. An ActiveSync partnership between
a unique client can be established to two hosts.
When the mobile device is reset (return to default settings), the random number is
deleted – and the partnership with the last one of the two hosts is also deleted. The host
retains the random numbers and unique names of all devices having a partnership with
it. Two clients cannot have a partnership with the same host if they have the same
name. (Control Panel > System > Device Name)
If the reset mobile device tries to reestablish the partnership with the same host PC, a
new random number is generated for the mobile device and ActiveSync will insist the
unique name of the mobile device be changed. If the mobile device is associated with a
second host, changing the name will destroy that partnership as well. This can cause
some confusion when re-establishing partnerships with hosts.
ActiveSync Help
ActiveSync on the host says that a device is trying to connect, but it cannot identify it
Verify the cable is attached to the Thor VM3. Disconnect and reconnect the cable from
the PC.
Check that the correct connection is selected.
Reset and Loss of Host Re-connection
, above.
ActiveSync indicator on the host (disc in the toolbar tray) turns green and spins as soon
as you connect the cable, before tapping the Connect icon (or REPLLOG.EXE in the
Windows directory).
One or more control lines are tied together incorrectly. This is usually a cable problem.
ActiveSync indicator on the host turns green and spins, but connection never occurs
Check that the correct connection is selected.
-or-
Incorrect or broken data lines in cable.
Содержание Thor VM3
Страница 1: ...User Guide Thor VM3 Vehicle Mount Computer with Microsoft Windows Embedded Compact 7 0 ...
Страница 12: ...xii Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 16: ...4 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 36: ...24 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 144: ...132 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 234: ...222 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 240: ...228 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 325: ...Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide 313 Hat Encoding ...
Страница 326: ...314 Thor VM3 with Microsoft Windows Embedded Compact 7 User Guide ...
Страница 378: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VM3 WEC UG Rev E 9 17 ...