
278
Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide
The Avalanche Enabler installation file HSM_ENABLER.CAB (older software loads may
use LXE_ENABLER.CAB instead) is loaded on the Thor VM2 by Honeywell; however, the
device is not configured to launch the Enabler installation file automatically. The instal-
lation application must be run manually the first time Avalanche is used.
After installation, the Enabler runs as a background application monitoring for updates.
This behavior can be modified by accessing the Avalanche Update Settings panel
through the Enabler interface.
This behavior can be modified by accessing the Avalanche Update Settings panel
through the Enabler Interface.
The RMU.CE.CAB file is placed on the device during manufacturing in the \Sys-
tem\RMU folder.
During the Enabler installation process, the Enabler checks for the RMU.CE.CAB file in
the \System folder.
•
If present, it assumes the RMU.CE.CAB file is already installed and continues.
•
If the file RMU.CE.CAB file is not present, it looks for the file in the \System\RMU
folder.
•
If present, the Enabler copies the file to the \System folder and installs it.
At this point, the OS will automatically install the Remote Management Utility (RMU)
after the Thor VM2 reboots.
Enabler Uninstall Process
To remove the Avalanche Enabler from the Thor VM2:
1. Delete the Avalanche folder located in the \System directory.
2. Warm boot the Thor VM2.
The Avalanche folder cannot be deleted while the Enabler is running. See
If sharing errors occur while attempting to delete the Avalanche folder, warm boot the
Thor VM2, immediately delete the Avalanche folder, and then perform another warm
boot.
Stop the Enabler Service
To stop the Enabler from monitoring for updates from the Mobility Center Console:
1. Open the Enabler Settings Panels by tapping the Enabler icon on the Thor VM2
desktop.
2. Select File > Settings.
3. Select the Preferences tab.
4. Select Do not monitor to prevent automatic monitoring upon Startup.
Содержание Thor VM2
Страница 1: ...User Guide Thor VM2 Vehicle Mounted Computer with Microsoft Windows Embedded CE 6 0 ...
Страница 16: ...4 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 63: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 51 ...
Страница 64: ...52 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 288: ...276 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 310: ...298 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 352: ...340 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Страница 385: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 373 Hat Encoding ...
Страница 398: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VM2 CE UG Rev D 9 17 ...