Honeywell T8424D Скачать руководство пользователя страница 3

T8424D ELECTRONIC MULTISTAGE THERMOSTAT

3

69-1386-1

Fig. 4. Wiring connections.

Fig. 5. Typical hookup of T8424 in two-stage heat and 

two-stage cool system with manual changeover.

Mounting Thermostat to Wallplate

1.

Engage the tabs at the top of the thermostat and 

wallplate.

2.

Swing down the thermostat and press the lower 
edge of the thermostat onto the wallplate to latch. 

See Fig. 6.

OPERATION

Setting FAN and SYSTEM Switches

Fan and system settings are controlled manually by 
using the switches located at the bottom of the 

thermostat case. See Fig. 7.

Fig. 6. Mounting thermostat wallplate.

FAN Switch

Fan switch settings are:

On: The fan runs continuously. Use for improved air 

circulation and air quality.

Auto: Normal setting for most homes. In cooling, the 

fan starts and stops with the cooling equipment. In 
heating, the fan is controlled directly by the heating 

equipment and may start a few minutes after the 
heating equipment turns on (on most systems). 

When using an electric heat thermostat, the fan 
starts and stops with the heating equipment.

Slide the FAN switch in the bottom left corner of the 

thermostat to select the desired fan setting.

SYSTEM Switch

System switch settings control thermostat operation as 
follows:

Cool: The thermostat controls the cooling system.
Off: Both heating and cooling are off.

Heat: The thermostat controls the heating system.

Slide the SYSTEM switch in the bottom right corner of 
the thermostat to select the desired system setting.

TERMINAL 
SCREW

M20212

G

R

C

Y

W1

B

O

FOR STRAIGHT 
INSERTION STRIP 
5/16 IN. (8 MM)

FOR WRAPAROUND 
STRIP 7/16 IN. (11 MM)

Y2

W2

L1 
(HOT)

L2

1

1

W2

Y

G

R

C

1ST STAGE
COOLING

2ND STAGE
COOLING

FAN
RELAY

STAGE-TWO
HEATING

Y2

24V

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

M20213

T8424

W1

STAGE-ONE
HEATING

M14677

SYSTEM

Cool  O

ff  Heat 

Auto  O

n

FAN

DASHED LINES INDICATE TABS
ON BACK OF THERMOSTAT

SYST

EM

Cool  Off  Heat

Auto  O

n

FAN

ENGAGE TABS  AT TOP  OF THERMOSTAT
WITH SLOTS ON MOUNTING PLATE.

PRESS LOWER EDGE OF 
CASE TO  LATCH.

A

B

Содержание T8424D

Страница 1: ...le for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation Location Install the thermostat about 5 ft 1 5m above the floor in an are...

Страница 2: ... shape of the terminals permits insertion of straight or wraparound wiring connections either method is acceptable See Fig 4 The T8424 Thermostat is powered through the system transformer and is adaptable to most 24 Vac multistage heating cooling systems Refer to Fig 5 for typical wiring hookups Fig 3 Restrict wiring to shaded area 5 FEET 1 5 METERS YES NO NO NO M11338 M12202A WALL WALL ANCHORS 2 ...

Страница 3: ...e heating equipment turns on on most systems When using an electric heat thermostat the fan starts and stops with the heating equipment Slide the FAN switch in the bottom left corner of the thermostat to select the desired fan setting SYSTEM Switch System switch settings control thermostat operation as follows Cool The thermostat controls the cooling system Off Both heating and cooling are off Hea...

Страница 4: ... set the F C indication and heat cycle rate 1 If the temperature is displayed in F set the tem perature setpoint to 52 F If the room temperature is displayed in C set the temperature setpoint to 11 C 2 Press the keys simultaneously for more than one second to light all segments on display and to enter installer setup mode When the keys are released a two digit software revision code is dis played ...

Страница 5: ...thm C3 Aggressive algorithm can cause overshooting 13 Press the key again Current configuration CC is displayed A typical example is shown but CC varies by model This information is for factory use only Table 1 Heating Cycle Rates for Stage Two Heating a High efficiency furnace bRefer to equipment manufacturer s instructions 14 Press the key to save all changes exit installer setup mode and return...

Страница 6: ... Press the key to lower the temperature setting several degrees below the room temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cool ing equipment 3 Press the key to raise the temperature setting above the room temperature Cooling system should shut down NOTE To bypass the 5 minute delay see the Optional System Checkout section Fan 1...

Отзывы: