T8141A ELECTRONIC HEAT PUMP THERMOSTATS

68-0169—1

3

INSTALLATION

When Installing this Product…

1. Read these instructions carefully. Failure to follow them

can cause a hazardous condition.

2. Check the ratings given in the instructions and on the

product to make sure the product is suitable for your
application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

CAUTION

Disconnect power supply to prevent electrical shock
or equipment damage.

RECYCLING NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do 

not place your old

control in the trash.

Contact your local waste management authority for
instructions regarding recycling and the proper
disposal of the old thermostat.

If you have questions, call Honeywell Inc. at 1-800-
468-1502.

Location

Install the thermostat about 5 ft (1.5m) above the floor in an
area with good circulation at room temperature.

Do not install the thermostat where it can be affected by:

drafts, or dead spots behind doors and in corners.

hot or cold air from ducts.

radiant heat from sun or appliances.

concealed pipes and chimneys.

unheated (uncooled) areas such as an outside wall
behind the thermostat.

If Replacing an Existing Thermostat

A

Turn off the thermostat power at the heat pump. In two-
transformer systems with two switches or disconnects;
turn off power to both.

B

Remove any existing wallplate or subbase from the
wall.

C

To avoid miswiring later, as the wire is removed, label
or write down each wire color with the letter or number
on the wiring terminal.

If New Installation

Run the cable to a hole at the selected wall location, and pull
about 6 in. (152 mm) of wire through the opening. Color-
coded, 18 to 22 gauge thermostat cable with at least one
conductor for each wiring terminal is recommended. Good
service practice recommends selecting cable with one or two
more conductors than the immediate application requires.

Mounting

Mount the thermostat horizontally on a wall. See Fig. 1 for
dimensions.

A

Hold mounting plate in position and mark the holes for
anchors.

B

Set aside the mounting plate.

C

Drill the three 3/16 in. (4.8 mm) holes and install the
three wall anchors (provided). Gently tap the anchors
into the holes until flush with the wall.

D

Pull the wires through the mounting plate cable
opening. See Fig. 2.

NOTE:

On a new installation, strip 3 in. (76 mm) of
cable sheathing off the end of the wire
bundle(s).

M5946A

2

UP

CABLE OPENING

MOUNTING HOLES (3)

MOUNTING PLATE

(81)

(87)

(94)

(40)

(51)

(38)

(6)

6-1/16 (154)

6-1/16 (154)

3-7/16

3-11/16

1-1/2

1/4

1-5/16

(33)

5-5/16 (135)

6-1/2 (165)

1-19/32

3-3/16

Fig. 1. Thermostat dimensions in in. (mm).

Содержание T8141A

Страница 1: ...32 C for heating and 60 F to 95 F 16 C to 35 C for cooling Retains setpoint temperature during power outage Cover thermometer Fan mode selection of AUTO ON System mode selections of EM HEAT HEAT OFF COOL some models have EM HEAT GEO HEAT OFF GEO COOL LED display for second stage AUX HEAT operation LED display for EM HEAT selection and external fault indication some models have GEO LOCK EM HEAT LED...

Страница 2: ...oducts from your contractor distributor or Honeywell sales representative please specify 1 Model number 2 Color choice for Heat or Cool changeover thermostat Cool Only changeover thermostat is only available in taupe 3 Thermostat changeover desired 4 System switches desired If you have additional questions need further information or would like to comment on our products or services please write o...

Страница 3: ...behind the thermostat If Replacing an Existing Thermostat A Turn off the thermostat power at the heat pump In two transformer systems with two switches or disconnects turn off power to both B Remove any existing wallplate or subbase from the wall C To avoid miswiring later as the wire is removed label or write down each wire color with the letter or number on the wiring terminal If New Installatio...

Страница 4: ...thermostat UP WALL MOUNTING SCREW M5948B TERMINAL STRIP TERMINAL WIRES FAN SWITCH SYSTEM SWITCH TEMPERATURE SETPOINT TEMPERATURE CONTROL DIAL 1 1 2 SNAP THE THERMOSTAT INTO THE TOP HINGES ON THE MOUNTING PLATE M8552 TERMINAL STRIP TERMINAL WIRES THERMOSTAT CABLE OPENINGS FOR STRAIGHT INSERTION STRIP 5 16 IN 8 MM FOR WRAPAROUND STRIP 7 16 IN 11 MM RESTRICT WIRING TO THIS AREA FRONT VIEW OF TERMINAL...

Страница 5: ...RELAY AUX HEAT RELAY COOL CHANGEOVER VALVE B HEAT CHANGEOVER VALVE L SYSTEM MONITOR M7777A E H O O C E H O C E H O C E H O C A EM HEAT HEAT OFF COOL SYSTEM SWITCH FAN SWITCH ON AUTO EM HEAT RED AUX HEAT GREEN FAN COMPRESSOR HEAT RELAY AUX HEAT RELAY THERMOSTAT LOGIC POWER SUPPLY TEMPERATURE SENSOR INTERNAL SYSTEM SWITCHES DESIGNATED AS E EM HEAT H HEAT O OFF C COOL INTERNAL FAN SWITCHES DESIGNATED...

Страница 6: ...nt during a power outage Temperature Setting Move the temperature control dial to the desired temperatures for heating and for cooling See Fig 7 System and Fan Switching System switch positions control thermostat operation as follows OFF Heating and cooling are off If the fan switch is in the AUTO position the cooling fan is also off HEAT or GEO HEAT Heating system is controlled by the thermostat ...

Страница 7: ...ature Cooling NOTE When the cooling setting is changed a minimum off timer delays the compressor from starting or stopping the heat pump for at least five minutes A Set the thermostat system switch to COOL or GEO COOL and the fan switch to AUTO B Set the temperature to about 10 F 6 C below the room temperature C Cooling and fan should start after a delay D Change the temperature setting to about 1...

Страница 8: ... the COOL position If the air conditioner comes on compressor could have reached its high limit temperature protection and shut down If cooling still does not start and the fault indicator is connected to terminal L and the EM HEAT indicator is on contact the Original Equipment Manufacturer or your HVAC dealer If the EM HEAT indicator is off contact Honeywell Customer Assistance at 1 800 468 1502 ...

Отзывы: