SYSNet™ QS7700A NETWORK INTERFACE ControlBus™ MODULE

63-2284—2

3

Canadian EMI: This digital apparatus does not exceed the
Class A limits for radio noise emission from digital apparatus
set out in the 

Radio Interference Regulations of the

Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant les limites applicables aux
appareils numériques de la Classe A prescrites dans le
Règlement sur le brouillage radioeléctrique édicté par le
ministère des Communications du Canada.

Humidity

Install the Network Interface Unit where the relative humidity
never reaches the saturation point. The Network Interface
Unit is designed to operate in an 85 percent relative humidity
continuous noncondensing moisture environment.
Condensing moisture can result in improper operation.

Vibration

Do not install the Network Interface Unit where it can be
subjected to excessive vibration in excess of  0.5G
continuous maximum vibration.

Weather

The Network Interface Unit is not designed to be weather
tight. If installed outdoors, the Network Interface Unit must be
protected.

Mounting the Network Interface Plug-in Card

NOTE:

For installation dimensions, see Fig. 1.

���

Mount the ControlBus™ Module in the Network
Interface Unit (see Fig. 2). Do 

not mount the Network

Interface Unit with the Network Interface Unit  edge
connector slots facing 

down.

���

Insert the ControlBus™ Module with the electrical
connector facing out from the Network Interface Base
Unit.

���

Grasp the ControlBus™ Module and align the plug-in
edge card with the connector in the bottom of the
Network Interface Unit.

���

Firmly insert the ControlBus™ Module into the Network
Interface Unit.

���

Select a location that can support the Network Interface
Unit. Be sure to allow clearances for servicing,
installation and removal of the wiring compartment
cover, Network Interface Unit cover, electrical
connectors and ControlBus™ Modules.

a.

Allow for an additional 2-1/2 inches (64 mm)
minimum below the Network Interface Unit for
electrical connector installation.

b.

Allow for an additional 1-1/2 inches (38 mm)
minimum on each side for electrical housing
cover insertion and wiring.

���

Remove the ControlBus™ Module by using the wire
loop and grasping the Wire loop firmly and pulling the
module from the Network Interface Unit.

WIRING

Wiring Requirements

1. All wiring must comply with all applicable electrical

codes, ordinances, and regulations.

2. Recommended wire size and type for ControlBus™

communication; terminal identification numbers are
noted within brackets:

1 [A]
2 [B]
3 [C]

Fig. 1. QS7700A Network Interface ControlBus™

Module dimensions in in. (mm).

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow them

could damage the product or cause a hazardous
condition.

2. Check the ratings given in the instructions and on the

product to make sure the product is suitable for your
application.

3. Installer must be a trained, experienced service

technician.

4. Check out the product after installation, as provided in

the Q7700 Network Interface Unit instructions,
form 63-2278.

5. Make sure that repairs are made only by the

manufacturer.

6. If trouble develops, disconnect the equipment from the

modem and determine the cause of the fault.
Reconnect only when the problem is corrected.

CAUTION

1.

Disconnect power supply before beginning
installation to prevent electrical shock and
equipment damage. More than one power supply
disconnection can be involved.

2.

Wiring must comply with all applicable codes,
ordinances and regulations.

3.

Refer to Fig. 6 for proper system wiring.

4.

Do not plug or unplug any Network Interface Unit
ControlBus™ Module or electrical connectors
with the power on. Make sure that power is off to
protect against equipment damage.

1

(25)

M2093

3-29/32
(99)

4-21/32

(118)

Содержание SYSNet QS7700A

Страница 1: ...ler Control System BCS 7700 FEATURES Up to six ControlBus Modules per Network Interface Unit Remote programming of nonsafety BCS 7700 values via the ControlBus Modules Local and remote annunciation of BCS 7700 faults Personal computer user interface Modular construction Microsoft Windows based Combustion System Manager user interface Microsoft Windows based SYSNet Operator user interface Contents ...

Страница 2: ...g 1 Weight 8 oz unpacked Accessories 221237 1698 Cover Assembly Q7700 Network Interface Unit 221240 1698 Cover Assembly Q7700 Electrical Enclosure Network Interface Unit 202433 Slot Inserts ControlBus Slots Base Unit 200603 ControlBus Electrical Connector Approvals Underwriters Laboratories Inc File No MP268 Guide No MCCZ2 Canadian Standards Association LR80141 Federal Communications Commission Pa...

Страница 3: ...ation and removal of the wiring compartment cover Network Interface Unit cover electrical connectors and ControlBus Modules a Allow for an additional 2 1 2 inches 64 mm minimum below the Network Interface Unit for electrical connector installation b Allow for an additional 1 1 2 inches 38 mm minimum on each side for electrical housing cover insertion and wiring Remove the ControlBus Module by usin...

Страница 4: ...sonal computer that will be connected to the 25 pin RS 232 port of the Network Interface Unit Mount the Network Interface Unit and insert the ControlBus Module into the Network Interface Unit slot see Fig 2 and 5 Route the ControlBus cable so that all devices are connected in a daisychain A A B B C C The BCS 7700 Chassis Module must be at one end of the daisy chain configuration string The interco...

Страница 5: ...EEN GROUND THE SYSTEM CONTROLBUS MUST BE ROUTED SO THAT ALL DEVICES ARE CONNECTED DAISY CHAIN CONFIGURATION A A B B C C THE SYSTEM CHASSIS AND PROGRAM MODULES MUST BE AT ONE END OF THE STRING THE INTERCONNECTION OF DEVICES IS NOT IMPORTANT EXCEPT THE DEVICE ON THE FARTHEST END OF THE DAISY CHAIN CONFIGURATION STRING MUST BE TERMINATED WITH A 120 OHM 1 4 WATT RESISTOR BETWEEN TERMINALS A AND B REMO...

Страница 6: ...SYSNet QS7700A NETWORK INTERFACE ControlBus MODULE 63 2284 2 6 ...

Страница 7: ...SYSNet QS7700A NETWORK INTERFACE ControlBus MODULE 63 2284 2 7 ...

Страница 8: ... Hong Kong Home and Building Control Honeywell Limited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 2C9 Honeywell Latin American Division Miami Lakes Headquarters 14505 Commerce Way Suite 500 Miami Lakes FL 33016 Helping You Control Your World 63 2284 2 G R Rev 7 96 Printed in U S A www honeywell com bbc Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapo...

Отзывы: