Honeywell Symphony Скачать руководство пользователя страница 3

 

 

 

- 3 -

 

 

 

Step-by-Step 

Tech Support 

 Updated 1/13/09 

This Section explains what wires are required to connect the Symphony.  

 

The following wire connection is required for Symphony operation:

  

 

4-conductor to control panel  

 

Category 5 Ethernet connection to the network router  

4-conductor to control panel 

 

This may be a standard 4-conductor security wire:  

 

You may use 22AWG for up to 100’ from the power supply  

 

You may use 18AWG for up to 250’ from the power supply  

 

You may use 16AWG for up to 400’ from the power supply  

Connections

 

1.

 

+12VDC – From power supply  

2.

 

+12VDC – From Control Panel (Can share from Terminal 1) 

3.

 

Ground – From power supply.   
BE SURE TO HAVE COMMON GROUND BETWEEN THE POWER SUPPLY AND CONTROL 
PANEL GROUND. 

4.

 

Data In – To Data In terminal on control panel  

5.

 

Data Out – To Data Out terminal on control panel  

  

Note: 

 

 

Power input to Pin 1 provides power for back light operation of keypad. You can use alternate power 
source or same power source used on pin 2. 

 

Only wiring pin 2 will result in dim back light and reduced life of the back light, so pin 1 must be powered 
under normal conditions. 

  

Category 5 Ethernet connection to the network router 

 

   

This connection is required for a network connection for Internet features.  

   

Category 5 (4 twisted pair – 24AWG) – Connects from RJ45 plug on back of Symphony and runs to the 

network router/hub/etc…  

Note: Internet connection is not required for Symphony keypad to operate  
 

Return to the table of contents

 

  
This section explains how much power is required by Symphony. The Symphony keypad REQUIRES A POWER 
SUPPLY due to the following current ratings:  
  

Event Action 

Current 

Standby   LCD off, Sound Off 

150mA maximum 

Active  

LCD on, Sound Off 

350mA maximum 

Alarm 

LCD off, Sound On 

200mA maximum 

Alarm  

LCD on, Sound Off 

400mA maximum 

The power supply should be rated at 400mA MINIMUM. The recommended power supply is the Ademco 
AD12612. This is a 1.2 Amp power supply. 

 

Return to the table of contents

 

Содержание Symphony

Страница 1: ... The Symphony keypad is compatible with the following Ademco panels Vista 20P Rev 3 and the 20PS Support s 2 Symphony keypads Vista 20p Rev 5 and higher will support up to 4 Symphony keypads Vista 20PI Support s 4 Symphony keypads First Alert FA148CP Supports 2 Symphony Keypads First Alert FA168CPS Supports 2 Symphony Keypads Vista 128BP 250BP Supports 3 Symphony Keypads Vista 128BP 250BP Rev 4 Su...

Страница 2: ...ote Only 1 Symphony keypad can be set above address 2 In the control panel device programming Program a device address for the Symphony keypad as an Alpha Keypad Set for the partition that you want and for the AUI prompt enter 1 for YES Set the Address in a Vista 20P Rev 3 20PS 20PI and FA148CP 168CPS control panel These panels support up to TWO Symphony keypads The 20PI supports 4 The Symphony de...

Страница 3: ...ht operation of keypad You can use alternate power source or same power source used on pin 2 Only wiring pin 2 will result in dim back light and reduced life of the back light so pin 1 must be powered under normal conditions Category 5 Ethernet connection to the network router This connection is required for a network connection for Internet features Category 5 4 twisted pair 24AWG Connects from R...

Страница 4: ... If the AUI and GMT time differ by 10 seconds or more the AUI time will be reset The Symphony will also send time to the control panel every hour This 1 hour timer starts on power up or when Sync to Network is selected if it was not set at power up This is true for all panels that support the AUI 20P series 128 250BP series 128 250FBP series and FA1660C 1700C as well Without Network Connection The...

Страница 5: ...k your setup 3 Wait for the system to update Verify that your Email is compatible 1 Your email service provider must use POP3 Post Office Protocol format with no security encryption 2 Some ISPs such as AOL use proprietary mail protocols that are not compatible with the Symphony 3 MSN uses encryption that causes it to be incompatible 4 Yahoo has POP3 email available but you must specifically sign u...

Страница 6: ...start the Symphony after each of these steps 3 Try connecting the Symphony directly to the router using a short pre manufactured Ethernet cable patch cord Use a cable that you can verify the integrity of by using it on another device such as a computer 4 Verify that a computer on the network is able to get its address through DHCP 5 Try connecting the Symphony to the same port of the router that y...

Страница 7: ...orm then click on CREATE ACCOUNT at the bottom 3 The primary username and password is for the end user to log in to the end user site to edit the web content for the Symphony This information will be emailed to the customer along with a link to the end user home page http symphony alarmnet com Add the Symphony console to the account 1 Click on MANAGE ACCOUNTS 2 Then for the account you are working...

Страница 8: ...he Symphony in the control panel based on its device address For Vista 128BP 250BP FA1660C and 128FBP panels support up to THREE Symphony keypads For Vista 250FBP and FA1700C panels support only ONE Symphony Keypad 1 The Symphony defaults for device address 01 If you have multiple Symphony keypads you must make each one a separate address 2 In the control panel device programming Program a device ...

Отзывы: