Honeywell SP5600-C OptimusR Скачать руководство пользователя страница 14

 

12

4.

 

Operations 

Batteries must be fresh and properly loaded before start operation. 

4.1

 

Keypad operations 

The 8300 Series Terminals have two keyboard layouts: 24 rubber keys and 39 rubber keys. The 
functions of some special keys are as follows: 

 
SCAN 

 

        Scan a barcode

Press this button will trigger the scanner to read a barcode if the scanner port is 
enabled. 

 
ENTER                  
Enter

There are two enter keys on the side of the scan key. Normally the enter keys are 
used for command execution or input confirmation. 
 

ESC

  

                

Escape

Usually this key is used to stop and exit current operation. 
 

BS   

                Back Space

.  

If this key is being pressed down longer than one second, a 

clear

 code will be 

sent. 
 

ALPHA / 

α

 

        The toggle key for Alphabet / Numeral input

When the system is in alpha-mode, a small icon will be shown on the display. For 
the 24-key keyboard, each numeral key can be used to generate one of the three 
capital letters. For example, numeral 

2

 can be used to produce 

A

B

 or 

C

. Pressing 

the same key twice within one second, will call the letter B. Pressing the same 
key without halting longer than one second, will cause the three letters to be 
shown in a circulating way. Only when stop pressing the key for longer than one 
second or pressing another key, will the system send the real key code to the 
application program. Pressing the “Alpha” key again, lower case letter can be 
inputted. 

 

FN                   

 

The function key

.  

This key cannot be activated alone, it must be pressed with one numeral key at 
the same time. For example, 

FN

 + 

1

 generates function #

1

FN

 + 

2

 generates 

function #

2

, etc (up to 9 functions). Also, this key can be combined with the 

UP/DOWN

 arrow keys to adjust the contrast of the LCD. And when this key is 

combined with the 

ENTER

 key, it will turn ON/OFF the backlight. 

 

POWER  

 

Power On/Off

To prevent a faulty push, it needs about 1.5 sec continuous pressing to turn 
On/Off the power. 

 

4.2

 

Application mode 

This is the default operation mode when turning on the power. The operation depends on the 
application module. Please refer to section 4.4. 

Содержание SP5600-C OptimusR

Страница 1: ...i SP5600 Terminal User s Guide Version 1 00 ...

Страница 2: ... 2 8 Keypad 4 2 9 Indicator 4 2 10 Communication 4 2 11 802 11b WLAN Specification 4 2 12 Software 4 3 Software Architecture 4 3 1 Kernel Application Manager 5 3 2 System 6 3 3 Application 11 3 4 Programming the terminal 11 3 5 Programming the communication cradle 11 4 Operations 12 4 1 Keypad operations 12 4 2 Application mode 12 4 3 System mode 13 4 4 Kernel mode 13 4 5 Application Manager 13 ...

Страница 3: ...rotection against harmful interference in a residential installation This equipment generates uses and can radiated radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Страница 4: ...rom windows to provide maximum shielding Equipment or its transmit antenna that is installed outdoors is subject to licensing Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device ...

Страница 5: ...ing IP65 2 3 Physical y Dimensions 194mm L x 77mm W x 44mm H y Weight 250g including battery y Color Black y Material ABS 2 4 CPU y Toshiba 16 bit CMOS type CPU y Tunable clock up to 22MHz 2 5 Memory Program memory y 1 M Bytes flash memory is used to store the program code font constant data and so on Data memory y 256K Bytes SRAM 2 6 Reader The 8300 Series Terminal can be equipped with either Las...

Страница 6: ... up to 115200bps y Standard IrDA Standard 1 0 compatible Baud rate up to 115200bps 2 11 802 11b WLAN Specification SP5600 Terminal y Frequency Range 2 4 2 5 GHz unlicensed ISM Band y Modulation DSSS with DBPSK 1M DQPSK 2M CCK 5 5 11M y Data Rate 11 5 5 2 1 Mbps Auto fallback y Channels Standard y Coverage 250M line of sight y Maximum Output Power 100mW y Compliance IEEE 802 11b Wi Fi compliance Ac...

Страница 7: ...rminal the following Application Manager s menu will be shown y Download To download application programs SHX BASIC run time BC83x0 SHX BASIC programs SYN or font files 8xxx XX SHX to the terminal There are 6 resident locations and one Active Memory i e at most 7 programs can be downloaded to the terminal But only the one downloaded to the Active Memory will be activated and running To run other p...

Страница 8: ...ower off when no operation is taking place during that specified period If this value is set to zero this function will be disabled Default 10 minutes 5 Power On Options There are two possible selections Program Resume which starts from the program being used during the last session before the last power off and Program Restart which starts with a new program Default Program Resume 6 Key Click Sel...

Страница 9: ...r with different Frequency Duration Press ENTER key to start and then press any key to stop the test 3 LCD LED To test LCD display and LED indicator Press ENTER key to start and then press any key to stop the test 4 Keyboard To test the rubber keys Press a key and the result will be shown on the LCD display Note that the FN key should be used in conjunction with numeral keys 5 Memory To test the d...

Страница 10: ...P settings to the terminal if DHCP Server is installed and the option is enabled These IP Settings also can be configured manually if DHCP is disabled Please contact your MIS engineer if you don t know how to configure it 1 DHCP DHCP stands for Dynamic Host Configuration Protocol Default 1 Enable 2 SubNet Mask The number used to identify the IP sub network indicating whether the IP address can be ...

Страница 11: ... when Power Saving is enabled Default 1 Enable 6 Preamble Select either a short preamble or long preamble Select a short preamble for SP5600 terminal with high network traffic select a long preamble when the network traffic is low Default 1 Long 4 Security 1 Authentication 802 11b supports two subtypes of network authentication services open system and shared key Open system authentication is used...

Страница 12: ...ey 3 EAP Menu EAP Stands for Extensible Authentication Protocol SP5600 terminal only support EAP MD5 When these features are implemented a wireless client that associates with an access point cannot gain access to the network until the user performs a network logon Therefore Identity and Password are needed when EAP is enabled EAP Setting EAP ID EAP Password 5 Echo Tests The terminal will echo the...

Страница 13: ...tor User s Guide 3 4 Programming the terminal There are three software tools available for developing application programs for the terminal 1 The Application Generator 2 The BASIC Compiler 3 The C Compiler Besides Terminal Emulation program which supports ANSI VT100 VT220 and IBM is also available For detailed information please contact Syntech Information Co Ltd 3 5 Programming the communication ...

Страница 14: ...ample numeral 2 can be used to produce A B or C Pressing the same key twice within one second will call the letter B Pressing the same key without halting longer than one second will cause the three letters to be shown in a circulating way Only when stop pressing the key for longer than one second or pressing another key will the system send the real key code to the application program Pressing th...

Страница 15: ...e refer to section 4 1 4 5 Application Manager Although the Application Manager is part of the kernel to enter it you need to press 8 and POWER key simultaneously Or if the application program does not exist the unit will automatically go to the Application Manager s menu upon power up The three services Download Activate and Upload provided by the Application Manager are explained in Section 4 1 ...

Отзывы: