SmartPAC 2 with WPC Integration
1126800
SmartPAC 2 Run Mode
Chapter 6
page 375
Operating the Press in Continuous Mode
DANGER
!
IMPROPER SAFEGUARDING
Ensure that the machine guarding system is installed and maintained according to OSHA
standard 1910.217, ANSI B11.1, ANSI B11.19 and any other regulations and standards that
apply. Ensure that guarding is properly installed to prevent access to the machine over,
under or around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
Two-hand Operation, Continuous Mode, page 375
Foot Operation, Continuous Mode, page 376
Operating the Press in Continuous On Demand Mode, page 377
To operate the press in continuous mode, you first need to set the stroke select switch to
continuous (CONT). Now set the mode select switch to either TWO HAND or FOOT.
Instructions for each setting are given below.
Two-hand Operation, Continuous Mode
DANGER
!
IMPROPER SAFEGUARDING
Ensure that the machine guarding system is installed and maintained according to OSHA
standard 1910.217, ANSI B11.1, ANSI B11.19 and any other regulations and standards that
apply. Ensure that guarding is properly installed to prevent access to the machine over,
under or around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
To operate the press in TWO HAND/CONT Mode, set the mode select switch to TWO
HAND and the Stroke Select switch to CONT. Then depress the PRIOR ACT switch.
While the PRIOR ACT indicator LED is lit (for eight seconds), press both RUN/INCH
buttons.
Keep the switches pressed until after the ram reaches bottom dead center. The press will now
operate continuously. The ram will stop if any of the following situations occur:
• a system fault is detected
• you press the EMERGENCY STOP / RESET switch.
• the light curtain is blocked during the non-muted portion of the stroke
• you press the Top Stop switch
• you did not keep run buttons pressed until Auto Carry-up
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...