background image

 

 

Ê800-24400ZŠ 

800-24400   5/18   Rev A 

 

 2018 Honeywell International Inc. Honeywell and is a registered 

trademark of Honeywell International Inc.   
All other trademarks are the properties of their respective owners. All 
rights reserved. 

 

24-HOUR ENROLLMENT DELETION AND DEFAULT 

If the device is enrolled in a panel different than the intended panel, and you are unable to 
delete it from the unintended panel, reset default the device to factory default setting: 

1. 

Open the cover and verify device is powered on. 

2. 

Press and hold the tamper switch for 20 seconds.  

3. 

The Green enrollment LED rapidly flashes and the SiXREPEATER defaults. 

This procedure is available for 24 hours after enrollment with a panel and the device 
remains powered (battery installed).

 

24-HOUR ENROLLMENT DELETION AND DEFAULT 

If the device is enrolled in a panel different than the intended panel, and you are unable 
to delete it from the unintended panel, reset default the device to factory default setting: 

1. 

Open the cover and verify device is powered on. 

2. 

Press and hold the tamper switch for 20 seconds 

3. 

The Green enrollment LED rapidly flashes and the SiXREPEATER defaults. 

This procedure is available for 24 hours after enrollment with a panel and the device 
remains powered (battery installed).

 

SENSOR LOCATION FEATURE 

To verify the location of each SiX device in an installation, enter programming mode and 
select a SiX device zone.  The device LED (located on the PCB) lights (can take up to 30 
seconds).  

NOTE:

  This LED is not seen with the cover on.  To view, the tamper switch 

must be pressed down on the SiXREPEATER.  Select it again to turn the LED off or 
select the next device to locate. 

SENSOR LOCATION FEATURE 

To verify the location of each SiX device in an installation, enter programming mode and 
select a SiX device zone.  The device LED (located on the PCB) lights (can take up to 30 
seconds).  

NOTE:

  This LED is not seen with the cover on.  To view, the tamper switch 

must be pressed down on the SiXREPEATER.  Select it again to turn the LED off or 
select the next device to locate.

 

SUPERVISION 

If module supervision is desired, assign the SiXREPEATER to a zone.  This sends check-
in, low battery, AC loss, and RF jam messages. When prompted, toggle the tamper 
switch to enroll the MAC ID number. The yellow LED should blink on when messages are 
sent. 

Program the zone configuration as follows: 

Zone Type 

Input Type 

Loop 

8 (24-hour aux) 

3 (supervised RF) 

NOTES: 

 

The SiXREPEATER reports AC loss and RF jam conditions as “low battery” 
status, which is also displayed on the control’s keypads. This prevents either 
condition from causing an alarm when the control is armed. 

 

The SiXREPEATER will not repeat a message that has already been 
repeated. 

 

If an actual low battery condition is reported, it takes up to 12 hours after AC 
power is restored for the low battery restore message to be sent (requires 12 
hours for fully recharged battery). 

SUPERVISION 

If module supervision is desired, assign the SiXREPEATER to a zone.  This sends 
check-in, low battery, AC loss, and RF jam messages. When prompted, toggle the 
tamper switch to enroll the MAC ID number. The yellow LED should blink on when 
messages are sent. 

Program the zone configuration as follows: 

Zone Type 

Input Type 

Loop 

8 (24-hour aux) 

3 (supervised RF) 

NOTES: 

 

The SiXREPEATER reports AC loss and RF jam conditions as “low battery” 
status, which is also displayed on the control’s keypads. This prevents 
either condition from causing an alarm when the control is armed. 

 

The SiXREPEATER will not repeat a message that has already been 
repeated.

 

 

If an actual low battery condition is reported, it takes up to 12 hours after 
AC power is restored for the low battery restore message to be sent 
(requires 12 hours for fully recharged battery).

 

TAMPER/LOW BATTERY REPORTING 

TAMPER/LOW BATTERY REPORTING

 

The SiXREPEATER reports this condition to the control. If a low battery or tamper 
condition exists all zones used on the module shows a trouble on the control. 

IMPORTANT:  

The first battery test occurs 1-hour after power up.  To quickly verify a good 
backup battery, unplug and then plug back in the power supply; the system will 
perform a battery test within 1-minute.

 

 

The SiXREPEATER reports this condition to the control. If a low battery or tamper 
condition exists all zones used on the module shows a trouble on the control. 

IMPORTANT:  

The first battery test occurs 1-hour after power up.  To quickly verify a good 
backup battery, unplug and then plug back in the power supply; the system will 
perform a battery test within 1-minute. 

 

LED INDICATIONS /

 LED INDICATIONS

 

 

 

 

 

 

RSSI 

Power 

RF Jamming 

Green /  

Green 

Reliable Signal / 

Reliable Signal

 

AC Powered /  

AC Powered 

OK, No Jamming /  

OK, No Jamming 

Yellow / 

Yellow

 

Marginal Signal /  

Marginal Signal 

Operating on Battery /  

Operating on Battery 

Jam Detected /  

Jam Detected 

Red / 

Red

 

No Signal /  

No Signal 

Low Battery /  

Low Battery 

Can’t Avoid Jamming / 

Can’t Avoid Jamming

 

Approval Listings / Approbations Homologations: 

FCC / IC - ETL Listed to UL268 & 521  
cETL Listed to ULC S530 & S531 
Other Standards / Autres normes:  RoHS

 

BATTERY /

 BATTERY

 

 

CAUTION! 

The batteries used in this device may present a fire or chemical burn hazard if mistreated.  
Do not recharge, disassemble, heat above 212°F (100°C) or dispose of in fire.  Use 
Panasonic CR123A or DURACELL DL123, DL 123A Lithium batteries. Use of other 
batteries may present a risk of fire or explosion. Keep used batteries away from children.  
Dispose of used batteries properly.  
Remove old batteries. Wait 10 seconds and then replace with four new batteries. To avoid 
a low battery indication when installing new batteries, both batteries must be installed 
within 15 seconds of installing the first one. Any low battery condition that may have 
occurred should clear when the back plate is installed.

 

MISE EN GARDE! 

Les piles utilisées dans ce dispositif peuvent présenter des risques d'incendie ou de 
brûlure chimique si elles sont mal traitées.  Ne rechargez pas, ne désassemblez pas, ne 
faites pas chauffer et ne jetez pas au feu les piles à plus de 100 °C (212 °F).  Utilisez des 
piles au lithium Panasonic CR123A ou DURACELL DL123, DL 123A.   L'utilisation 
d'autres types de piles peut présenter des risques de feu ou d'explosion. Gardez les 
vieilles piles hors de la portée des enfants.  Débarrassez-vous des batteries utilisées de 
façon appropriée. 
Retirez les vieilles piles.  Attendez 10 secondes et remplacer-les par quatre nouvelles 
piles. Pour éviter une indication de piles faibles lorsque vous installez de nouvelles piles, 
les dos (2) piles doivent être installées en deçà de 15 secondes après l'installation de la 
première. Toute condition de pilles faibles qui aurait pu se produire devrait être rétablie 
une fois la plaque arrière installée. 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS 
DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM 
SYSTEM. 
POUR LES LIMITES DU SYSTÈME D’ALARME AU COMPLET, REPORTEZ-VOUS AU 
GUIDE D’INSTALLATION DU PANNEAU DE COMMANDE

 

 

Support / Pour de l’assistance en ligne, visitez 

https://mywebtech.honeywellhome.com/ 

U.S. warranty / U.S. garantie: 

www.honeywell.com/security/hsc/resources/wa 

For patent info, see: / Pour des informations sur les brevets, voir : 

www.honeywell.com/patents 

 

MyWebTech 

 

Warranty 

 

Patents 

 

FEDERAL COMMUNICATIONS COMMISSION (FCC) & ISED 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation 
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the 
equipment. 

FCC / ISED STATEMENT 

This device complies with Part 15 of the FCC Rules, and ISED’s license-exempt RSSs. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any 
interference received, including interference that may cause undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’ISED. Son 
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences 
nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une 
réception indésirable. 

Responsible Party / Issuer of Supplier’s Declaration 
of Conformity: Honeywell International, 2 Corporate 
Center Drive., Melville, NY 11747, Ph: 516-577-2000 

Partie responsable / Émetteur de la déclaration de 
conformité du fournisseur : Honeywell 
International, 2 Corporate Center Drive., Melville, 
NY 11747, Tél. 516 577-2000 

 

B

SPECIFICATIONS / SPÉCIFICATIONS: 

Voltage / 

Voltage

 

Transformer Part # /

 Transformer Part #

 ........................... 300-10259 

Input Voltage / 

Input Voltage

 ............................................ 100 ~ 240VAC, 50 ~60 Hz 

Operating Voltage / 

Operating Voltage

 ............................. 5VDC (1A)

 

Maximum Transformer Distance / 

Maximum Transformer Distance

 ....................................... 9.8ft. (3m) 

Battery/ Pile ...................................................................... P/N 300-10342

 

Environmental /

Environmental

 

Operating Temperature / 

Operating Temperature

 .................................................... 14 

F (-10

C) to 140

F (60

C) 

NOTE: 

Charging the lithium battery stops when temperature is below 32

F (0

C) 

NOTE: 

Charging the lithium battery stops when temperature is below 32

F (0

C) 

Relative Humidity / 

Relative Humidity

 ............................... 95%, Non-condensing / 95% 

 ......................................................................................... max. sans condensation

 

Physical / 

Physical

 

Dimensions / 

Dimensions

 ................................................. 

Length / 

Length

 6.9 in (175 mm) x  

 

Width

 

Width

4

.4 in (113 mm) x  

 

Depth / 

Depth

 1.2 in (31 mm) 

Conduit Insert / 

Conduit Insert

 .......................................... 1/2 in (12.7mm) 

Acceptable Cable Size / 

Acceptable Cable Size

 ............... 14 – 22AWG

 

See 

Honeywell Installation Guide 

P/N 800-

24399– https://mywebtech.honeywell.com/. 

Voir les instructions d'installation complètes 800-

24399- https://mywebtech.honeywell.com/. 

 

 

Отзывы: