background image

Sensepoint Plus, Sensepoint Pro, Series 3000 XPIS and Sensepoint XCD Duct Mounting Kit 

Issue 3 07/2009 

MAN0639

4

Assembling Detector Components

1   Fit the Detector to the Mounting Plate.

 

Screw the detector firmly into the plate mounting hole in a clockwise direction.

2   Fit the Sensor Retainer to the Detector.

NOTE THAT THE DETECTOR 

SHOWN IS SENSEPOINT PRO

SENSEPOINT PLUS,  

SERIES 3000 XPIS AND  

SENSEPOINT XCD FIT IN  

EXACTLY THE SAME WAY

3   Fit a link pipe 

(5 mm ID)

 between the retainer port and the gas inlet port on the underside  

 

of the Mounting Plate.

 

Screw the retainer firmly onto the detector in a clockwise direction.

Note: Sensor retainer of duct mounting kit for Sensepoint Pro is not compatible with Series 3000 XPIS.

Содержание Sensepoint XCD

Страница 1: ...Sensepoint Plus Sensepoint Pro Series 3000 XPIS and Sensepoint XCD Duct Mounting Kit Installation Guide ...

Страница 2: ...int Pro Series 3000 XPIS or Sensepoint XCD gas detector to a duct Part No SPPPDM is for Sensepoint Plus and Sensepoint Pro S3KDMK is for Series 3000 XPIS SPXCDDMK is for Sensepoint XCD The duct mounting kit is only suitable for use in applications for the detection of Flammable Carbon Monoxide Hydrogen Sulphide and Hydrogen gases It comes as a pre assembled kit fitted to a supplied sample part duc...

Страница 3: ...stant holes around it use the part duct as a template 3 Align the Gasket over the holes Refer to the following diagram for the component positioning 4 Fit the Gasket Retaining Plate over the gasket 5 Fit the four Plate Fixings through the duct wall from the inside The hexagon shaped step on the fixings align with the hexagon shaped holes in the retaining plate 6 Secure the plate to the fixings usi...

Страница 4: ...ction 2 Fit the Sensor Retainer to the Detector NOTE THAT THE DETECTOR SHOWN IS SENSEPOINT PRO SENSEPOINT PLUS SERIES 3000 XPIS AND SENSEPOINT XCD FIT IN EXACTLY THE SAME WAY 3 Fit a link pipe 5 mm ID between the retainer port and the gas inlet port on the underside of the Mounting Plate Screw the retainer firmly onto the detector in a clockwise direction Note Sensor retainer of duct mounting kit ...

Страница 5: ...POINT XCD FIT IN EXACTLY THE SAME WAY 2 Clamp the Detector Assembly down Use the 4 x M6 hex head securing screws to firmly secure the Detector Mounting Plate to the Duct Assembly 3 Cap off the external gas inlet port on the top of the Mounting Plate until needed Mounting the Detector Assembly to the Duct Assembly 1 Place the Detector Assembly onto the Duct Assembly Retaining Plate fitted to the du...

Страница 6: ... www honeywell com Technical Services EMEAI HAexpert honeywell com US ha us service honeywell com AP ha ap service honeywell com Asia Pacific Honeywell Analytics Asia Pacific 508 Kolon Science Valley I 187 10 Guro Dong Guro Gu Seoul 152 050 Korea Tel 82 0 2 2025 0300 Fax 82 0 2 2025 0329 analytics ap honeywell com Please Note While every effort has been made to ensure accuracy in this publication ...

Отзывы: