32 

 

MANUAL  - Manually controls the Night Shot mode in LOCAL 
CONTROL option.   On/Off Night Shot mode remotely by pressing  

10

ON

10

OFF

 

3.4.8  CAMERA DEFAULT

 

MENU

  => CAMERA =>CAMERA DEFAULT)

 

   Returns all changed camera values to factory default . 
 
 
 
 
 
 
 
 
 

3.5  SETUP 

(

 

MENU

  

=> SETUP)

 

 
 
 
 
 
 
 
 
 
 
 
 
 

3.5.1 FLIP

  

(MENU  => SETUP => FLIP) 

When the ScanDome camera is mounted on a ceiling, you can set one of three ways in how it 
can track a target moving in a path directly below the camera: 

ON

 - When the camera reaches the floor directly above the moving object, the dome camera 

tracks the object smoothly with a digitally corrected image. 

OFF

 

 The dome camera does not perform a flip. 

 

3.5.2 SPEED

  

(

MENU

  

=> SETUP => SPEED)

 

User can select preferable speed curves of manual control.( FAST / SLOW / MED) 
 

3.5.3 PRESET FREEZE

 (

MENU

  

=> SETUP => PRESET FREEZE)

 

This option is used to set the pause previous image until the preset action is complete. 
 

 

CAMERA DEFAULT 

 

ARE YOU SURE : (Y/N) 

YES : ENTER OR MENU KEY 

NO  : ESC KEY 

 

 

  SETUP MENU 

 

FLIP          : ON/OFF 
SPEED         : FAST 
PRESET FREEZE : ON/OFF 
PANNING RANGE 

TILT OVER ANGLE 

CALIBRATION 
LINE LOCK CONTROL 
FACTORY DEFAULT 
ERASE DATA 

SYSTEM INFORMATION 

EXIT

 

Содержание ScanDome III HSDC-231N/P

Страница 1: ...ScanDome TM llI Dome Camera HSDC 251N P HSDC 231N P Please read this manual thoroughly before use and keep it handy for future reference Rev 060210 Operation Programming Manual ...

Страница 2: ...h with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing i...

Страница 3: ...TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DIGITAL APPARATUS COMPLIES WITH C...

Страница 4: ...f the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service personnel Servicing is req...

Страница 5: ...r 3 Program and Operation 16 3 1 FUNCTION 16 3 1 1 HOME FUNCTION MENU FUNCTION HOME FUNCTION 17 3 1 2 PRESET MENU FUNCTION PRESET Short Cut PRST 18 3 1 3 PATTERN MENU FUNCTION PATTERN or Shortcut PTRN 19 3 1 4 SCAN MENU FUNCTION SCAN or Shortcut SCAN 21 3 1 5 TOUR or MENU FUNCTION TOUR Short Cut TOUR 22 3 2 ALARM MENU ALARM 23 3 3 SCREEN 25 3 3 1 LANGUAGE MENU SCREEN LANGUAGE 25 3 3 2 PRIVACY ZONE...

Страница 6: ...MENU CAMERA CAMERA DEFAULT 32 3 5 SETUP MENU SETUP 32 3 5 1 FLIP MENU SETUP FLIP 32 3 5 2 SPEED MENU SETUP SPEED 32 3 5 3 PRESET FREEZE MENU SETUP PRESET FREEZE 32 3 5 4 PANNING RANGE MENU SETUP PANNING RANGE 33 3 5 5 TILT OVER ANGLE MENU SETUP TILT OVER ANGLE 33 3 5 6 CALIBRATION MENU SETUP CALIBRATION 33 3 4 7 LINE LOCK CONTROL MENU CAMERA L L CONTROL 34 3 5 8 FACTORY DEFAULT MENU SETUP FACTORY ...

Страница 7: ...Tours Tour can be expanded up to 500 different functions using nested Tours Smooth DiagonalScan mode and programmable Individual dwell time camera functions Speed Dwell time BLC BMB Focus IRIS of the preset 8 Alarm inputs with 0 8 priority 2 Auxiliary outputs programmable NC NO 8 Privacy Zones Video off or up to 8 masked blocks and 8 mask color selectable 64 steps of variable speed from 0 1 sec to...

Страница 8: ... variety of external switching devices such as multiplexers MUXes and Digital Video Recorders DVRs may be incorporated to accommodate the needs from the small to large surveillance security system Figure 1 illustrates a small sample installation Figure 1 Typical System Configuration ...

Страница 9: ...L6 COM2 NC2 NO2 GND AL5 24V 24V FG RX RX TX TX GND TERMINATION ON Chapter 2 Installation and Configuration 2 1 Unpacking the box The package contains the following Quantity Component 1 ScanDomeTM III Dome Camera 1 Instruction Manual this document 3 Assembly Screws for Attaching ScanDome 3 Plastic Anchor 1 3 Pin Connector 1 4 Pin Connector 2 8 Pin Cable Assembly 3 3 Bolt Spacer Use for HSGN 502 and...

Страница 10: ...tches Figure 3 Layout of Switches 2 3 Principle of Termination Every device which is connected at the end of the communication data line must be terminated by either DIP switch setting or appropriate devices such as a termination jumper to prevent potential control signal errors See Figure 4 for termination switch settings and Figure 5 for examples of devices requiring termination Note Total lengt...

Страница 11: ...meras are installed using two or more DVRs the following formula is useful to determine the Dome ID ID 16x n 1 m where n number of DVR m Camera Port SW2 Termination ON SW2 Termination ON TERMINATION ON SW2 Termination ON DVR Termination ON S1 Dome1 port Termination ON S1 Dome1 port Termination ON SW2 Termination ON SW2 Termination ON DVR Termination ON SW2 Termination ON SW2 Termination ON SW2 Ter...

Страница 12: ...h as a joystick controller or DVR RS 485 Connect the TXA Tx and TXB Tx of the RS485 control devices KDB DVR to RX RX of the dome camera DOME ID S3 S2 S1 1 0 0 1 999 9 9 9 1 2 3 4 5 6 7 8 9 0 S1 S2 S3 S6 S5 S4 3 2 6 5 4 8 7 9 1 0 3 2 6 5 4 8 7 9 1 0 on on on Function D1 VIDEO D2 COMM D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 Ex tended ID Protocol Baud rate Camera S6 S5 Dip s w S4 OFF ON Camera D3 D4 Default...

Страница 13: ...3 Program and Operation for configuring alarm input Pin configuration of the supplied alarm cable JP4 and JP2 GND Ground NOTE All the connectors marked GND are common Connect the ground of the Alarm input and or alarm output to the GND connector NO NC Normally Opened or Normally Closed dry contact relay output The dome camera can activate external devices such as buzzers or lights using dry contac...

Страница 14: ... designed to mount on a structural surface supporting loads up to 5 Kg See Figure 8 o c o c Figure 8 Example of a ceiling mounted installation 2 8 Power on and Boot up Sequence When the power is applied to the dome camera it will start a boot up sequence When boot up is done the following information is displayed on the monitor screen Fasten Screw Lock CW Unlock CCW ...

Страница 15: ...OMEIII Vx xxx CAMERA TYPE xxxx WAIT DOME SETTING INIT TILT ORIGIN SET OK INIT PAN ORIGIN SET OK INIT CAMERA SET OK 001 PRESET W EMPTY DATA ALARM 1 360 0 090 0 DOME NO 0001 Preset No Information Alarm Display Dome Camera Title Dome Camera ID Compass Direction Pan Tilt Angle Preset Title Or Area Title ...

Страница 16: ...amming editing mode Button or Joystick movement in menu Function Joystick left or right Go into the sub menu items Execute the command exit Change value Navigate through the menu items Joystick up or down Navigate through the menu items Joystick down Finish editing title Zoom handle twist Change value Increase Decrease Enter editing title mode SHFT Joystick PTZ control mode ESC Escape from the men...

Страница 17: ...rogram the Home function 1 Select the camera number by pressing No and CAM 2 Press MENU to display the main menu on the monitor 3 Push the Joystick to the right on FUNCTIONS 4 Enter Home Function menu by pushing the Joystick to the right 5 Push the Joystick to the right left or twist CCW CW to scroll Tour Pattern Auto Scan and Preset functions 6 Select Function Number by pushing the Joystick down ...

Страница 18: ...resets may be assigned to alarm actions or as the home position for the dome camera Locate the cursor on the PRESET item and then push the joystick to the right to enter PRESET menu There are 31 pages of preset programming menu Each page can hold 8 presets Locate the cursor on PREV NEXT preset menu pages can be scrolled by pushing the Joystick to the Left or Right on the PREV NEXT F Focus I IRIS B...

Страница 19: ...h entering the title push the Joystick up downward 8 Locate the cursor on PREV NEXT item to select the previous next page of presets scroll the page by pushing the Joystick to the Left on PREV NEXT 9 Repeat steps 2 through 8 for each additional preset position 10 Select Save and Exit by pushing the Joystick to the right Press ESC to exit the Preset menu without saving NOTE Press the Home or OFF bu...

Страница 20: ...rol for view selection and hit the Focus button to stop 5 Scroll down to the Save and Exit option and push the Joystick to the right to save and exit 6 You can title the selected Pattern by twisting the Joystick Rotate the handle clockwise or counterclockwise to scroll through the alphanumeric characters push the handle to right or left to select next or previous space 7 Pressing ESC will not save...

Страница 21: ...erclockwise or moving the Joystick left right to select the auto scan speed 5 When finish entering the title select START ANGLE with the Joystick Hold down the SHFT PGM key while selecting the start position using the Joystick Current panning position will be displayed Release SHFT PGM key to complete the selection of the start position Or twist zoom handle or hit zoom button to start PTZ control ...

Страница 22: ...llustrated by the following example If Tour 01 Preset 02 Preset 03 Tour 02 Tour 03 Tour 02 Preset 05 Preset 06 Tour 04 Preset 05 Tour 03 Preset 07 Pattern 01 Tour 04 Preset 08 Preset 05 Pattern 01 Tour1 executes as follows Preset 02 è Preset 03 è Preset 05 è Preset 06 è Preset 05 è Preset 07 è Pattern 01 è Repeat Tour 04 in Tour 02 will be skipped in Tour 01 Tour 02 executes as follows Preset 05 è...

Страница 23: ...8 Presets Tours Patterns Scans can be selected for a Tour You can expand the Tour sequence by calling other programmed tours Push the Joystick handle to right or left while the cursor is on the top of the line TOUR 01 to select another page of the Tour menu TOUR 01 7 You can enter a title for the selected Tour by twisting the Joystick while the cursor is on the top of the line TOUR 01 Rotate the h...

Страница 24: ...y the main menu on the monitor Select the Alarm option by pushing the Joystick up or down and push to right to enter the detail menu 2 Select the alarm input number by pushing the Joystick up or down and select the column you wish to setup Selected position will be highlighted 3 Select the Preset Status of Input NC NO OFF and Output OUT1 2 OFF by pushing the Joystick to the right or to the left 4 ...

Страница 25: ...o the right to enter SCREEN menu 3 3 1 LANGUAGE MENU SCREEN LANGUAGE Push the joystick handle to the right to select LANGUAGE options Preferred language will be scrolled when you push the joystick to the right on LANGUAGE ENGLISH MAIN MENU FUNCTION ALARM SCREEN CAMERA SETUP EXIT SCREEN MENU LANGUAGE PRIVACY ZONE NORTH DIRECTION ZONE TITLE CAMERA TITLE EXIT LANGUAGE SETUP LANGUAGE ENGLISH SAVE AND ...

Страница 26: ...h entering the title push the Joystick down or press the ENTR key 4 To adjust the marked privacy area press and hold down the SHFT PGM key and then use the Joystick direction and zoom until you get desired view Release the key the right column will be set to ON Or twist zoom handle or hit zoom button to start PTZ control for view selection and hit the Focus button to exit from control mode 5 You c...

Страница 27: ...lease the key then current pan angle will be displayed on position item Or twist zoom handle or hit zoom button to start PTZ control for view selection and hit the Focus button to exit from control mode 3 3 4 ZONE TITLE MENU SCREEN ZONE TITLE Enter a specific name in sectioned angle between START and END DISPLAY ON OFF zone title on the screen 1 Press MENU SCREEN ZONE TITLE to display zone title m...

Страница 28: ... previous page or next page of the menu 6 Save and exit the program by pushing the Joystick to the right Press ESC to exit the program without saving 3 3 5 CAMERA TITLE MENU SCREEN CAMERA TITLE Push the joystick handle to the right to select CAMERA TITLE options 1 Twist the joystick handle on the TITLE CAMERA NO to enter camera title You can select alphanumeric characters by rotating the handle Mo...

Страница 29: ...S 10 0 15 DIGITAL ZOOM OFF 2X 4X MAX NIGHT SHOT CAMERA DEFAULT SAVE AND EXIT 3 4 1 FOCUS CONTROL MENU CAMERA FOCUS CONTROL MODE AUTO MANUAL CAUTION Avoid continuous 24 hour use of the auto focus heavy movement condition This will shorten the lifespan of the lens 3 4 2 WB white balance MENU CAMERA WB CONTROL FOCUS SETUP MODE MANUAL SAVE AND EXIT ESC TO EXIT WB SETUP MODE ATW CONT AUTO EXIT ...

Страница 30: ...11 F9 6 F8 0 F6 8 F5 6 F4 8 F4 0 F3 4 F2 8 F2 4 F2 0 GAIN 8 DB 10 DB 38 DB SHUTTER 1 60 1 50 1 100 1 120 1 1000 1 2000 1 4000 1 10000 NOTE Values in are for PAL Camera 3 4 4 BLC BMB SETUP MENU è CAMERA èBLC BMB SETUP Objects in front of bright backgrounds will be clearer with BLC ON AUTO BMB BMB Black Mask BLC It is another function of BLC It mask the excessive light to dark level and make brighte...

Страница 31: ...x 10x respectively 3 4 7 NIGHT SHOT MENU MENU CAMERA NIGHT SHOT The NIGHT SHOT option removes the IR Cut filter of the camera and makes the camera sensitive to near infrared If NIGHT SHOT mode of the selected camera is set to Manual 10 ON will enable the NIGHT SHOT mode 10 OFF will turn off the NIGHT SHOT mode MODE MANUAL AUTO AUTO Camera automatically goes into B W mode at low light BLC BMB SETUP...

Страница 32: ...camera reaches the floor directly above the moving object the dome camera tracks the object smoothly with a digitally corrected image OFF The dome camera does not perform a flip 3 5 2 SPEED MENU SETUP SPEED User can select preferable speed curves of manual control FAST SLOW MED 3 5 3 PRESET FREEZE MENU SETUP PRESET FREEZE This option is used to set the pause previous image until the preset action ...

Страница 33: ...n this option is chosen the dome will tilt up over the horizon About 5 degrees When the lens is zoomed out you can see the ceiling line But when the lens is zoomed in the viewing angle is narrower and the ceiling line disappears W O BUBBLE The tilt range of the camera is limited to see the horizon so the picture shows part of the ceiling line WITH BUBBLE The tilt range of the camera is limited to ...

Страница 34: ...with other PHASE 0 255 cameras in EXTERNAL mode EXIT ESC TO EXIT 3 5 8 FACTORY DEFAULT MENU SETUP FACTORY DEFAULT Programmed data go back to initial state as ex factory 3 5 9 ERASE DATA MENU SETUP ERASE DATA Erase programmed data in the EEPROM of the selected dome camera Press MENU or ENTER button to erase data ESC key to exit without erasing Origin offset value is not affected LINE LOCK SETUP MOD...

Страница 35: ...Refer to Download Upload data function in the Keyboard Configuration utility 3 5 10 SYSTEM INFORMATION MENU SETUP ERASE DATA This screen shows information of the dome camera for service or trouble shooting SYSTEM INFORMATION CAMERA TYPE XXXXXXX H W VERSION V1 0 ROM VERSION V1 0 PROTOCOL S2E BUADRATE 9600BPS EXIT ...

Страница 36: ... N ratio more than 50dB Camera HSDC 231NX PX Image Sensor 1 4 Exview Color CCD Sony Picture elements NTSC 768x494 Approx 380K pixels PAL 752x582 Approx 440K pixels Horizontal Resolution 470 460 lines NTSC PAL Lens 23x optical zoom with auto focus 10x digital zoom F1 6 to F3 8 f 3 8mm to 87 4mm View angle Approx 50 7 WIDE end to 2 36 TELE end Minimum Illumination 0 7 lx 30 IRE Day Night OFF 0 06 lx...

Страница 37: ...m F1 6 to F3 7 f 3 8mm to 95mm View angle Approx 56 2 WIDE end to 2 4 TELE end Minimum Illumination 0 7 lx 30 IRE Day Night OFF 0 06 lx 30 IRE Day Night ON 0 005 lx Field integration x128 ON 0 0005 lx 30 IRE Night ON Field integration x128 ON S N ratio more than 50dB Controller specifications General Certification CE EMC FCC CLASS A Electrical Input Voltage 18 to 30 VAC 24 VAC nominal built in pow...

Страница 38: ... Autoscan 16 auto scan include vector scan 1 Auto Pan Preset Position 248 positions with camera status 16 character title Tour 8 tours Pattern Four patterns 240 second On Screen Display Displays camera ID and area name on screen Environment Operating temperature 0 C to 50 C 32 F to 122 F Operating humidity 0 to 90 RH non condensing Storage temperature 20 C to 60 C 4 F to 140 F Specifications are s...

Страница 39: ...itches are in the ON position Check that the BNC connectors are inserted properly see Figure 4 Poor video quality Check the voltage level of the dome camera Check the power supply voltage nominal 24VAC Dome cameras lose their positions Reset the cameras using the Dome configuration menus Check if there is unusual sound Check the voltage level of the dome camera Camera number does not match the mul...