Страница 1: ...et the best use of the product please read the User Guide carefully before using the product Keep the User Guide at an easily accessible place and make it available to the next user 2010 Honeywell International Inc All rights reserved http www security honeywell com Document 800 04997 Rev A ...

Страница 2: ......

Страница 3: ...in the structure itself which may cause nuisance alarms Bells Human activity Do not apply the detectors close to the bells Or apply a piece of tape on the bell to suppress the overtones generated in the frequency range of the detectors Apply carpet or vibration damping material on vaults and under safes placed on concrete or marble floors Regular maintenance and inspection at least annually by the...

Страница 4: ...F IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the product s it sells may not be compromised or circumvented that the product s will prevent ...

Страница 5: ...lanning Protections 7 Mini ATMs 7 Vending Machines and Ticket Machines 7 6 Installation 9 Mounting the Detector 9 Opening the Detector 9 Mounting on Steel 9 Mounting on Stainless Steel or Hardened Steel 10 Mounting the Accessories 11 The Movable Mounting Kit SC111 11 The Keyhole Protection Kit SC112 11 The Spacer for Keyhole Protection Kit SC118 11 The Armored Cable Kit SC114 12 The Test Transmitt...

Страница 6: ...ounting Kit SC111 Components 11 Figure 6 5 Keyhole Protection Kit SC112 Components 11 Figure 6 6 Spacer for Keyhole Protection Kit SC118 Components 11 Figure 6 7 Armored Cable Kit SC114 12 Figure 6 8 Test Transmitter SC113 12 Figure 6 9 External Test Transmitter SC115 Components 12 Figure 7 1 Function modules on Detector Base 13 Figure 8 1 Wirings on the terminal block 15 Figure 8 2 Alarm and tamp...

Страница 7: ...Honeywell iii Tables Table 2 1 Application Settings 2 Table 9 1 Remote Test 17 ...

Страница 8: ......

Страница 9: ...Seismic Vibration Detector SC105 and related accessories Chapter 7 Settings shows how to configure sensitivities and other settings on Mini Seismic Vibration Detector SC105 base Chapter 8 Connecting the Detector introduces how to wire and connect Mini Seismic Vibration Detector SC105 to the protected zone Chapter 9 Test introduces the tests of the Mini Seismic Vibration Detector SC105 Chapter 10 T...

Страница 10: ...hines According to the vibration characteristics of the application constructions sensitivity required in each sensor and the natural vibrations and ambient noise level in the premises the detection ranges of Detector SC105 should follow the parameters in the table below Table 2 1 Application Settings Sensitivity Settings Material Detection Radius Applications Noise Level Steel 3 0 m Ghigh Concret...

Страница 11: ...tch sensitivity settings adapt to various applications Integrated EOL resistors compatible with various control panels High detection capability due to new sophisticated signal handling and computer algorithms incorporated Low current consumption Solid state form A breaking alarm relay Multipurpose accessories provided with multiple applications Standard drill sheet protection Rate of Rise and tem...

Страница 12: ... level detection mode is designed to recognize low to medium amplitude signals with long duration like those caused by a thermic lance oxy arc or acetylene torch The medium level detection mode is designed to detect medium to high amplitude signals as caused by mechanical demolition such as electric power tools The high level detection mode is designed to detect very high amplitude and short durat...

Страница 13: ...or transistor output going into conductive mode upon alarm condition The transistor is protected against overload with a series resistor of 1 38k ohm Note No protection against sabotage attempts with external magnetic fields is needed due to solid state alarm relay Power Supply Block The input circuits are very well protected against electrical interference and high energy electrical surges by fil...

Страница 14: ...asic Accessories Mounting Plate SC110 Movable Mounting Kit SC111 Keyhole Protection Kit SC112 Test Transmitter SC113 Spacer for Keyhole Protection Kit SC118 External Test Transmitter SC115 Armored Cable Kit 8 wires SC114 6 ...

Страница 15: ...mmend mounting At least one detector on or inside the safe cabinet close to the dispenser opening One detector on the door close to or between the hinges or inside the door leaf Figure 5 1 Planning ATM Protection Close to the dispenser opening On or inside the door The Movable Mounting Kit SC111 or the Keyhole Protection Kit SC112 and the Armored Cable Kit SC114 can be used when mounting detectors...

Страница 16: ...Planning Protections Figure 5 2 Planning Vending Machine Ticket Machine Protection Close to expected attack spot Close to coin bill compartment 8 ...

Страница 17: ...and smooth steel surface both Drill Plan see Figure 6 2 Drill Plan and Detector Base see Figure 2 1 Detector Description can be used to mark the mounting holes Figure 6 2 Drill Plan Note Please remove the drill plan after mounting holes have been drilled C A A B Detector SC100 mounting hole C Test Transmitter SC113 mounting hole Note The drill plan shall be removed after all of the mounting holes ...

Страница 18: ...eel or hardened steel the Mounting Plate SC110 UPSIDE DOWN must be used and should be welded on the mounting surface first Figure 6 3 Mounting Plate SC110 UPSIDE DOWN F G C D E A B A B Detector SC105 mounting holes C D Test Transmitter SC113 locating hole E Mounting Plate SC110 mounting hole F G Welding Slots Refer to the steps below to mount the Detector SC105 on stainless steel or hardened steel...

Страница 19: ...111 For more information please refer to Movable Mounting Kit SC111 User Guide Figure 6 4 Movable Mounting Kit SC111 Components Mounting Plate Day Position Plate Night Position Plate The Keyhole Protection Kit SC112 The Keyhole Protection Kit SC112 is used with Detector SC105 to prevent unlocking during armed installation or loading explosives into the keyhole as it at the same time is a mounting ...

Страница 20: ...o mount the Test Transmitter SC113 please refer to Mounting the Detector on page 9 Figure 6 8 Test Transmitter SC113 The External Test Transmitter SC115 The SC115 External Test Transmitter is a range test transmitter developed to generate a simulated attack signal in protected object with multiple SC105 seismic detectors installed in concrete vaults and all other solid structure value storage unit...

Страница 21: ...itch 3 will cause an alarm Any change of DIP switch 3 must be followed by a power off sequence of 5 seconds Application setting with DIP switch 3 in ON position gives normal 100 response time to alarm In applications with intermittent noise a delayed 200 response to alarm is possible by setting DIP switch 3 in OFF position Example A Lobby ATM with extensive internal or external intermittent noise ...

Страница 22: ...y one EOL value can be set Other EOL resistor values can be used by removing all jumpers on the EOL jumper field and wire new resistors directly on the terminal block J19 J20 Settings No Jumper Jumper J19 Terminal 8 Spare Terminal Terminal 8 Alarm O C Output J20 Connect SC111 SC112 to the loop Normal Close Factory default settings are shown in grey J1 Setting J1 is used for remote test and for all...

Страница 23: ...the terminal block Note The open collector alarm output terminal 8 will be active low during alarm 5 Connect the detector to the panel according to the actual applications See Figure 8 2 for connecting the detector to a zone configured as Dual End of Line and Figure 8 3 for connecting the detector to a zone configured as Single End of Line Figure 8 2 Alarm and tamper configured to one loop RTI RSI...

Страница 24: ... This test simulates an attack from extensive mechanical force or explosives Note Check up the background noise level in the detector to prevent nuisance alarm 3 Activate the Noise LED tool by setting the DIP switch 4 in ON position 4 Set the sensitivity to Ghigh Make sure that all possible sources of vibrations in the protected area are present and operating 5 Check the noise LED that shall not l...

Страница 25: ...ting of the signal propagation in the solid structure of the protected object betw External Test Trans l functions a wn in the Functio Method R No test Connect jumper to J1 pin 1 only or no jumper at all with SC115 including See External Test Transmitter SC115 User Guide Range test External Test Transmitter mounting check 1 Connect jumper to J1 pin 1 and 2 Apply an active low 0 volt to A successfu...

Страница 26: ...Open Collector Active low during alarm Ri 1 38 kΩ Alarm Hold Time Approx 2 5 sec Sabotage Protection Pry off and Cover Switch 30 VDC 100 mA Low Supply Voltage Alarm 6 5 VDC Temperature Alarm 85 C 5 C Internal Functional Alarm Stainless steel drill shield Sabotage and fault functions will cause the alarm relay to drop Inputs Remote test of detector mounting and detector function or Remote test of d...

Страница 27: ......

Страница 28: ...ty de Honeywell Security Group Via della Resistenza 53 59 20090 Buccinasco Italia Tel 39 0 248 880 51 www honeywell com Per ulteriori informazioni Fax 39 0 248 880 55 33 Email info hsce italia honeywell com www honeywell com security it Honeywell Security Group Ampèrestraat 41 1446 TR Purmerend Nederland Tel 31 0 299 410200 www honeywell com Voor meer informatie Fax 31 0 299 410201 Email intrusion...