Advanced Installation Guide
69-2578EF—01 22
Troubleshooting
SETUP
WIRING
ASSIST
ANCE
TR
OUBLESHOO
TING
Customer assistance
For assistance with this product, please visit
http://yourhome.honeywell.com
or call Honeywell
Customer Care toll-free at
1-800-468-1502
.
Temperature
settings do not
change
Make sure heating and cooling
temperatures are set to acceptable
ranges:
• Heat: 40° to 90°F (4.5° to 32°C).
• Cool: 50° to 99°F (10° to 37°C).
“Cool On” or
“Heat On” is
flashing
•
Compressor protection feature is
engaged. Wait 5 minutes for the
system to restart safely, without
damage to the compressor.
“Heat On” is
not displayed
•
Set the System switch to Heat, and
set the temperature level above the
current room temperature.
“Cool On” is
not displayed
•
Set the System switch to Cool, and
set the temperature level below the
current room temperature.
Содержание RTHL 2310 series
Страница 1: ...Quick Installation Guide RTHL2310 RTHL221 Series Programmable Thermostat 69 2578EF 01 ...
Страница 3: ...1 69 2578EF 01 M28097 1 Turn Off Power to Heating Cooling System ...
Страница 12: ...69 2578EF 01 10 Turn the power back on to the heating cooling system 10 Turn Power Back On M28098 ...
Страница 27: ...69 2578EF 01 Série RTHL2310 RTHL221 Thermostat programmable Guide d installation rapide ...
Страница 29: ...1 69 2578EF 01 M28097 1 Couper l alimentation vers le système de chauffage refroidissement ...
Страница 35: ...7 69 2578EF 01 RTHXXXX M32707 Installer deux piles alcalines AAA Dos du thermostat 7 Installer les piles ...