RP418A, B, C AND RP818A, B ELECTRIC/PNEUMATIC RELAYS

Automation and Control Solutions

Honeywell

Honeywell Limited-Honeywell Limitée

1985 Douglas Drive North

35 Dynamic Drive

Golden Valley, MN  55422

Scarborough, Ontario
M1V 4Z9

Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.

Fig. 2. RP418 or RP818 relays mounted directly to an 

MP516A operator using the 14003638-001 adaptor kit.

Fig. 3. RP418 or RP818 relays mounted directly to a 

VP512C valve using the 14003638-001 adaptor kit.

Wiring and Piping

All pneumatic piping connections on the RP418 and RP818 

are sized for 1/4-in. (6mm) OD polyethylene tubing. The con-
nections are sharp, barb-type connections. See Fig. 6 and 7.
Wiring connections on the RP418A and RP818A are made via 

splices inside the splice box. Knockouts are provided on the 

box. For ambient temperatures between 100 to 120°F (38 to 
49°C) either use 75°C rated wire or attach a close-coupled 

4 x 4 electrical box to the RP418A or RP818A splice box. 

Make the wire splices within the electrical box. 
Wire leads provide a means of connection on the RP418B 
and RP818B. Use standard wire nut connectors, obtained 

locally, when making these connections. 
NOTE: A cord and plug are provided for wiring connections 

on the RP418C.

The RP418 and RP818 relays require no adjustment or 
calibration.

Fig. 4. RP418 or RP818 relays mounted directly to a 

PP901B pressure regulator using the 14003638-001 

adaptor kit.

Fig. 5. RP418 or RP818 relays mounted directly to a PP902 

pressure regulator using the 14003638-001 adaptor kit.

Fig. 6. RP418 and RP818 typical wiring and piping.

Fig. 7. Pneumatic schematic.

MP516A

BRACKET

RP418 OR RP818

M18372

M18373

RP418 OR RP818

BRACKET

VP519C

M18375

PP910B

BRACKET

RP418 OR RP818

PP920B

BRACKET

RP418 OR RP818

M18374

FAN
SWITCH

FAN MOTOR

DAMPER

EXHAUST

DAMPER
OPERATOR

RP418 OR
RP818

SUPPLY
AIR

VOLTAGE
SUPPLY

M18298

1

2

3

M18299

DEENERGIZED: 
PORTS 2 AND 
3 CONNECTED,
PORT 1 BLOCKED.

ENERGIZED:  
PORTS 1 AND 
3 CONNECTED, 
PORT 2 BLOCKED.

3

1

2

2

3

1

Содержание RP418B

Страница 1: ...ned locally NOTE When wall mounting use the mounting holes on the sides of the relay valve body or the knockout mount ing holes on the inside of the splice box See Fig 2 3 Attach the relay to the panel using mounting screws obtain locally Panel Mounting 1 Line up the no 8 mounting holes on the sides of the valve body with existing holes in the panel or drill new holes 1 in 25 mm apart 2 Attach the...

Страница 2: ...o 49 C either use 75 C rated wire or attach a close coupled 4 x 4 electrical box to the RP418A or RP818A splice box Make the wire splices within the electrical box Wire leads provide a means of connection on the RP418B and RP818B Use standard wire nut connectors obtained locally when making these connections NOTE A cord and plug are provided for wiring connections on the RP418C The RP418 and RP818...

Страница 3: ...ARQUE Dans le cas d un montage mural utiliser les trous de montage situés sur les côtés du corps de la vanne du relais ou les ouvertures défonçables à l intérieur de la boîte de jonction Voir la Fig 2 3 Fixer le relais sur le panneau au moyen de vis de mon tage non fournies Montage sur panneau 1 Aligner les trous pour des vis de montage no 8 de chaque côté du corps de la vanne sur les trous déjà p...

Страница 4: ...fil conçu pour une température de 75 C ou fixer une boîte électrique à couplage direct de 4 x 4 sur la boîte de jonction du RP418A ou RP818A Des fils conducteurs permettent de raccorder le RP418AB ou le RP818B Utiliser des raccords de fils à écrou non fournis avec ces conducteurs REMARQUE Un cordon avec fiche est fourni pour le raccor dement du RP418C Le RP418 et le RP818 ne nécessitent ni réglage...

Отзывы: