11
11
REMOTE AND INDOOR TEMPERATURE
The remote temperature information line is located on the top line of the main
unit’s display.
The wave icon is located above the remote channel number indicates the
reception status from the corresponding remote sensor.
There are three following types of the reception status may be displayed:
The unit is in a searching
mode.
Temperature reading is
securely registered.
No signals detected.
- - -
The indoor temperature with the icon IN is located below the remote
temperature information line.
NOTE: If the indoor or remote temperature goes above or below operating
range stated in specifications, the main unit’s display ( weather) will show
dashes “- - -” on the corresponding line.
MAXIMUM AND MINIMUM READINGS
The maximum and minimum record of the indoor and remote temperature will
be automatically stored in the memory of the main unit (receiver).
To display the minimum, maximum or the current reading press MEM button.
If no button is pressed for the next 15 seconds, the unit will return to the current
temperature and humidity display.
To clear the memory, press and hold MEM button for two seconds and all
previously stored readings will be erased.
12
LOST COMMUNICATION
If the main unit display line for the remote sensor reading goes blank, press
and hold DOWN (▼) button for 2 seconds to begin a new signal search. If the
signal still isn’t received, please make sure that:
·
The remote sensor is in its proper location.
·
The distance between main unit and remote sensor(s) is not over 200
feet (60 meters)
·
The path between units is clear of obstacles. Shorten the distance if
necessary.
·
Fresh batteries are installed correctly in both remote sensor and main
unit.
If there is no reception, please perform the following steps:
·
Bring the main unit and remote sensor close together.
·
Remove four (4) small screws from the back of the remote sensor with
small Phillips screwdriver, and open the battery compartment.
·
Remove the batteries from the battery compartment and reinstall them
in the same manner. Remote sensor LED indicator will flash showing
transmission of the signal.
·
Remove the batteries from the main unit and reinstall them in the same
manner.
·
On the main unit select the same channel number using CHANNEL
button as set on the remote sensor. The remote temperature appeared
on the main unit’s display will show that transmission is being received
successfully.